SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:lup.lub.lu.se:02a07a7a-0903-4ff0-b8cb-cd4d1b089ce2"
 

Sökning: onr:"swepub:oai:lup.lub.lu.se:02a07a7a-0903-4ff0-b8cb-cd4d1b089ce2" > The volume-expandin...

The volume-expanding effects of autologous liquid stored plasma following hemorrhage.

Bentzer, Peter (författare)
Lund University,Lunds universitet,Anestesiologi och intensivvård,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Anesthesiology and Intensive Care,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
Thomas, Owain (författare)
Lund University,Lunds universitet,Anestesiologi och intensivvård,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Anesthesiology and Intensive Care,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
Westborg, Johan (författare)
visa fler...
Johansson, Pär I (författare)
Schött, Ulf (författare)
Lund University,Lunds universitet,Anestesiologi och intensivvård,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Anesthesiology and Intensive Care,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
visa färre...
 (creator_code:org_t)
2012-09-14
2012
Engelska.
Ingår i: Scandinavian Journal of Clinical and Laboratory Investigation. - : Informa UK Limited. - 1502-7686 .- 0036-5513. ; 72:6, s. 490-494
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: Plasma use has increased since studies have suggested that early treatment with blood components in trauma with severe hemorrhage may improve outcome. Plasma is also commonly used to correct coagulation disturbances in non-bleeding patients. Little is known about the effects of plasma transfusion on plasma volume. We report a prospective interventional study in which the plasma volume-expanding effect of autologous plasma was investigated after a controlled hemorrhage. Methods: Plasma obtained by plasmapheresis from nine healthy regular blood donors was stored at 2-6°C. Five weeks after donation the subjects were bled of 600 ml and then transfused with 600 ml of autologous plasma. Plasma volume was estimated using (125)I-albumin before and after bleeding, and immediately after plasma transfusion. Plasma volume changes were then estimated by measuring changes in hematocrit during the following 3-h period. Results: Estimated plasma volume after bleeding was 3170 ± 320 ml and 3690 ± 380 ml (mean ± standard deviation) immediately following the transfusion of plasma (p 0.05). This increase in plasma volume corresponds to 86 ± 13% of the infused volume. Three hours after transfusion, plasma volume was still 3680 ± 410 ml. Conclusions: Stored liquid plasma has a plasma volume expanding effect up to 86% of its infused volume with a duration of at least 3 h.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Anestesi och intensivvård (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Anesthesiology and Intensive Care (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Bentzer, Peter
Thomas, Owain
Westborg, Johan
Johansson, Pär I
Schött, Ulf
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Anestesi och int ...
Artiklar i publikationen
Scandinavian Jou ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy