Sökning: onr:"swepub:oai:lup.lub.lu.se:16c2a22a-40b5-4b1d-bed6-b0682f4163a1" >
Estimation of f-wav...
Estimation of f-wave Dominant Frequency Using a Voting Scheme
-
- Biton, Shany (författare)
- Technion - Israel Institute of Technology
-
- Suleiman, Mahmoud (författare)
- Rambam Medical Center
-
- Moshe, Noam Ben (författare)
- Technion - Israel Institute of Technology
-
visa fler...
-
- Sornmo, Leif (författare)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,LTH profilområde: Teknik för hälsa,LTH profilområden,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH,LTH Profile Area: Engineering Health,LTH Profile areas,Faculty of Engineering, LTH
-
- Behar, Joachim A. (författare)
- Technion - Israel Institute of Technology
-
visa färre...
-
(creator_code:org_t)
- 2022
- 2022
- Engelska.
-
Ingår i: Computing in Cardiology, CinC 2022. - 9798350300970
- Relaterad länk:
-
http://dx.doi.org/10... (free)
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.2...
-
visa färre...
Abstract
Ämnesord
Stäng
- Atrial fibrillation (AF) is the most common heart arrhythmia, characterized by the presence of fibrillatory waves (f-waves) in the ECG. We introduce a voting scheme to estimate the dominant atrial frequency (DAF) of f-waves. Methods: We analysed a subset of Holter recordings obtained from the University of Virginia AF Database. 100 Holter recordings with manually annotated AF events, resulting in a total 363 AF events lasting more than 1 min. The f-waves were extracted using four different template subtraction (TS) algorithms and the DAF was estimated from the first 1-min window of each AF event. A random forest classifier was used. We hypothesized that better extraction of the f-wave meant better AF/non-AF classification using the DAF as the single input feature of the RF model. Results: Performance on the test set, expressed in terms of AF/non-AF classification, was the best when the DAF was computed computed the three best-performing extraction methods. Using these three algorithms in a voting scheme, the classifier obtained AUC=0.60 and the DAFs were mostly spread around 6 Hz, 5.66 (4.83-7.47). Conclusions: This study has two novel contributions: (1) a method for assessing the performance of f-wave extraction algorithms, and (2) a voting scheme for improved DAF estimation.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Medicinsk bioteknologi -- Biomedicinsk laboratorievetenskap/teknologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Medical Biotechnology -- Biomedical Laboratory Science/Technology (hsv//eng)
Publikations- och innehållstyp
- kon (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas