SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:lup.lub.lu.se:3eb98788-0223-4ba9-9e43-e85b281af822"
 

Sökning: onr:"swepub:oai:lup.lub.lu.se:3eb98788-0223-4ba9-9e43-e85b281af822" > MSIWarp : A General...

  • Eriksson, Jonatan O.Lund University,Lunds universitet,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Clinical Protein Science and Imaging,Forskargrupper vid Lunds universitet,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH,Lund University Research Groups (författare)

MSIWarp : A General Approach to Mass Alignment in Mass Spectrometry Imaging

  • Artikel/kapitelEngelska2020

Förlag, utgivningsår, omfång ...

  • 2020-12-02
  • American Chemical Society (ACS),2020

Nummerbeteckningar

  • LIBRIS-ID:oai:lup.lub.lu.se:3eb98788-0223-4ba9-9e43-e85b281af822
  • https://lup.lub.lu.se/record/3eb98788-0223-4ba9-9e43-e85b281af822URI
  • https://doi.org/10.1021/acs.analchem.0c03833DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:art swepub-publicationtype
  • Ämneskategori:ref swepub-contenttype

Anmärkningar

  • Mass spectrometry imaging (MSI) is a technique that provides comprehensive molecular information with high spatial resolution from tissue. Today, there is a strong push toward sharing data sets through public repositories in many research fields where MSI is commonly applied; yet, there is no standardized protocol for analyzing these data sets in a reproducible manner. Shifts in the mass-to-charge ratio (m/z) of molecular peaks present a major obstacle that can make it impossible to distinguish one compound from another. Here, we present a label-free m/z alignment approach that is compatible with multiple instrument types and makes no assumptions on the sample's molecular composition. Our approach, MSIWarp (https://github.com/horvatovichlab/MSIWarp), finds an m/z recalibration function by maximizing a similarity score that considers both the intensity and m/z position of peaks matched between two spectra. MSIWarp requires only centroid spectra to find the recalibration function and is thereby readily applicable to almost any MSI data set. To deal with particularly misaligned or peak-sparse spectra, we provide an option to detect and exclude spurious peak matches with a tailored random sample consensus (RANSAC) procedure. We evaluate our approach with four publicly available data sets from both time-of-flight (TOF) and Orbitrap instruments and demonstrate up to 88% improvement in m/z alignment.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Sánchez Brotons, AlejandroUniversity of Groningen (författare)
  • Rezeli, MelindaLund University,Lunds universitet,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Clinical Protein Science and Imaging,Forskargrupper vid Lunds universitet,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH,Lund University Research Groups(Swepub:lu)elma-mrl (författare)
  • Suits, FrankIBM Australia Ltd (författare)
  • Markó-Varga, GyörgyLund University,Lunds universitet,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Clinical Protein Science and Imaging,Forskargrupper vid Lunds universitet,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH,Lund University Research Groups(Swepub:lu)akem-gmv (författare)
  • Horvatovich, PeterLund University,Lunds universitet,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH,University of Groningen(Swepub:lu)pe4034ho (författare)
  • Institutionen för biomedicinsk teknikInstitutioner vid LTH (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Analytical Chemistry: American Chemical Society (ACS)92:24, s. 16138-161480003-27001520-6882

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy