Immobilised activated sludge based biosensor for biochemical oxygen demand measurement
-
- Liu, Jing (författare)
- Lund University,Lunds universitet,Bioteknik,Centrum för tillämpade biovetenskaper,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Biotechnology,Center for Applied Life Sciences,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
-
- Björnsson, Lovisa (författare)
- Lund University,Lunds universitet,Miljö- och energisystem,Institutionen för teknik och samhälle,Institutioner vid LTH,Lunds Tekniska Högskola,Environmental and Energy Systems Studies,Department of Technology and Society,Departments at LTH,Faculty of Engineering, LTH
-
- Mattiasson, Bo (författare)
- Lund University,Lunds universitet,Bioteknik,Centrum för tillämpade biovetenskaper,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Biotechnology,Center for Applied Life Sciences,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
-
(creator_code:org_t)
- 2000
- 2000
- Engelska.
-
Ingår i: Biosensors & Bioelectronics. - 1873-4235. ; 14:12, s. 883-893
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- A biochemical oxygen demand (BOD) sensor, based on an immobilised mixed culture of microorganisms in combination with a dissolved oxygen electrode, has been developed for the purpose of on-line monitoring of the biological treatment process for waste and wastewater. The sensor was designed for easy replacement of the biomembrane, thereby making it suitable for short-term use. The drawbacks of activated sludge based sensor, such as short sensor lifetime, were thereby circumvented. The sensor BOD measurements were carried out in the kinetic mode using a flow injection system, resulting in 25 s for one measurement followed by 4-8 min recovery time. Based on the results of normalised sensor responses, the OECD synthetic wastewater was considered to be a more suitable calibration solution in comparison with the GGA solution. Good agreement was achieved between the results of the sensor BOD measurement and those obtained from BOD5 analysis of a wastewater sample from a food-processing factory. Reproducibility of responses using one sensor was below +/-5.6% standard deviation. Reproducibility of responses using different sensors was within acceptable bias limits, viz. +/-15% standard deviation.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Industriell bioteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Industrial Biotechnology (hsv//eng)
Nyckelord
- Biochemical oxygen demand
- Activated sludge
- Microbial consortium
- Kinetic mode
- Dynamic mode
- Wastewater
- BOD sensor