Sökning: onr:"swepub:oai:lup.lub.lu.se:7b8acf9c-185d-4496-86ae-485ea2724a33" >
Feasibility and saf...
Feasibility and safety of synchrotron-based X-ray phase contrast imaging as a technique complementary to histopathology analysis
-
- Li, Kan Yan Chloe (författare)
- University College London
-
- Dejea, Hector (författare)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,MAX IV-laboratoriet,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH,MAX IV Laboratory,ETH Zürich,Paul Scherrer Institute
-
- De Winne, Koen (författare)
- Antwerp University Hospital
-
visa fler...
-
- Bonnin, Anne (författare)
- Paul Scherrer Institute
-
- D’Onofrio, Valentino (författare)
- Hasselt University
-
- Cox, Janneke A. (författare)
- Hasselt University
-
- Garcia-Canadilla, Patricia (författare)
- University of Barcelona
-
- Lammens, Martin (författare)
- Antwerp University Hospital
-
- Cook, Andrew C. (författare)
- University College London
-
- Bijnens, Bart (författare)
- Catalan Institution for Research and Advanced Studies,Institutd' Investigacions Biomèdiques August Pi iSunyer (IDIBAPS)
-
- Dendooven, Amélie (författare)
- Antwerp University Hospital,Hasselt University
-
visa färre...
-
(creator_code:org_t)
- 2023
- 2023
- Engelska 13 s.
-
Ingår i: Histochemistry and Cell Biology. - 0948-6143. ; 160:5, s. 377-389
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- X-ray phase contrast imaging (X-PCI) is a powerful technique for high-resolution, three-dimensional imaging of soft tissue samples in a non-destructive manner. In this technical report, we assess the quality of standard histopathological techniques performed on formalin-fixed, paraffin-embedded (FFPE) human tissue samples that have been irradiated with different doses of X-rays in the context of an X-PCI experiment. The data from this study demonstrate that routine histochemical and immunohistochemical staining quality as well as DNA and RNA analyses are not affected by previous X-PCI on human FFPE samples. From these data we conclude it is feasible and acceptable to perform X-PCI on FFPE human biopsies.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Medical Engineering -- Medical Image Processing (hsv//eng)
Nyckelord
- Needle biopsies
- Pathology
- X-ray phase contrast imaging
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas
- Av författaren/redakt...
-
Li, Kan Yan Chlo ...
-
Dejea, Hector
-
De Winne, Koen
-
Bonnin, Anne
-
D’Onofrio, Valen ...
-
Cox, Janneke A.
-
visa fler...
-
Garcia-Canadilla ...
-
Lammens, Martin
-
Cook, Andrew C.
-
Bijnens, Bart
-
Dendooven, Améli ...
-
visa färre...
- Om ämnet
-
- TEKNIK OCH TEKNOLOGIER
-
TEKNIK OCH TEKNO ...
-
och Medicinteknik
-
och Medicinsk bildbe ...
- Artiklar i publikationen
-
Histochemistry a ...
- Av lärosätet
-
Lunds universitet