Sökning: onr:"swepub:oai:lup.lub.lu.se:7cd16412-cd78-49fd-8772-9740a059ddbf" >
Non-axisymmetric En...
Non-axisymmetric Endwall film cooling characteristics considering the influences of cylindrical holes and laidback fan-shaped holes
-
- Du, Kun (författare)
- Northwestern Polytechnic University
-
- Jia, Yihao (författare)
- Northwestern Polytechnic University
-
- Liu, Cunliang (författare)
- Northwestern Polytechnic University
-
visa fler...
-
- Sunden, Bengt (författare)
- Lund University,Lunds universitet,NanoLund: Centre for Nanoscience,Annan verksamhet, LTH,Lunds Tekniska Högskola,Värmeöverföring,Institutionen för energivetenskaper,Institutioner vid LTH,LTH profilområde: Nanovetenskap och halvledarteknologi,LTH profilområden,LU profilområde: Ljus och material,Lunds universitets profilområden,Other operations, LTH,Faculty of Engineering, LTH,Heat Transfer,Department of Energy Sciences,Departments at LTH,Faculty of Engineering, LTH,LTH Profile Area: Nanoscience and Semiconductor Technology,LTH Profile areas,Faculty of Engineering, LTH,LU Profile Area: Light and Materials,Lund University Profile areas
-
visa färre...
-
(creator_code:org_t)
- 2024
- 2024
- Engelska.
-
Ingår i: International Journal of Heat and Mass Transfer. - 0017-9310. ; 225
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Flow fields near the turbine vane endwall are complicated due to the endwall cross flows. The use of a non-axisymmetric endwall is regarded as an efficient technique to reduce the lateral pressure difference, decreasing the endwall cross flow. Numerical analysis was performed to determine how the non-axisymmetric endwall affected the vortex structure and heat transfer level. The cooling performance was investigated with cylindrical and laidback fan-shaped holes (7–7–7), which were arranged in rows aligned in the axial direction. The results showed that the non-axisymmetric endwall could significantly reduce the circumferential pressure difference and suppress the growth of the passage vortex, and the area-averaged heat transfer coefficient was reduced by 3.34%. The outlet area of the film hole was altered by the non-axisymmetric endwall, and the over-cooled regions may have appeared as a result of the excessive area increase. The influence of the non-axisymmetric endwall was concentrated at 0.4 < Z/Cax < 1.0 for the cylindrical hole. With the increase in M, the film cooling effectiveness of the non-axisymmetric endwall attained a higher level than that of the flat endwall. For the laidback fan-shaped hole, the effect of the non-axisymmetric endwall was confined within 0.25 < Z/Cax < 1.0. The half-period trigonometric function of the non-axisymmetric endwall (HTFN) achieved the optimal cooling performance for three blowing ratios. However, the periodic trigonometric function of the non-axisymmetric endwall (PTFN) only outperformed the flat endwall when M= 1.5.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Maskinteknik -- Strömningsmekanik och akustik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Mechanical Engineering -- Fluid Mechanics and Acoustics (hsv//eng)
Nyckelord
- Aerodynamic characteristics
- Film cooling
- Laidback Fan-shaped Hole
- Non-axisymmetric endwall