Automated interpretation of ventilation-perfusion lung scintigrams for the diagnosis of pulmonary embolism using support vector machines

Ericsson, Anders (författare)
Lund University,Lunds universitet,Matematik LTH,Matematikcentrum,Institutioner vid LTH,Lunds Tekniska Högskola,Mathematics (Faculty of Engineering),Centre for Mathematical Sciences,Departments at LTH,Faculty of Engineering, LTH
Huart, A (författare)
Ekefjard, A (författare)
visa fler...
Åström, Karl (författare)
Lund University,Lunds universitet,Matematikcentrum,Institutioner vid LTH,Lunds Tekniska Högskola,Centre for Mathematical Sciences,Departments at LTH,Faculty of Engineering, LTH
Holst, H (författare)
Evander, Eva (författare)
Lund University,Lunds universitet,Klinisk fysiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Clinical Physiology (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Wollmer, Per (författare)
Lund University,Lunds universitet,Klinisk fysiologi och nuklearmedicin, Malmö,Forskargrupper vid Lunds universitet,Clinical Physiology and Nuclear Medicine, Malmö,Lund University Research Groups
Edenbrandt, Lars (författare)
Lund University,Lunds universitet,Nuklearmedicin, Malmö,Forskargrupper vid Lunds universitet,Nuclear medicine, Malmö,Lund University Research Groups
visa färre...
 (creator_code:org_t)
2003
2003
Engelska.
Ingår i: 13th Scandinavian Conference, SCIA 2003 Halmstad, Sweden, June 29 – July 2, 2003 Proceedings/Lecture Notes in Computer Science. - 0302-9743 .- 1611-3349. - 9783540406013 ; 2749, s. 415-421
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • The purpose of this study was to develop a new completely automated method for the interpretation of ventilation-perfusion (V-P) lung scintigrams for the diagnosis of pulmonary embolism. A new way of extracting features, characteristic for pulmonary embolism is presented. These features are then used as input to a Support Vector Machine, which discriminates between pulmonary embolism or no embolism. Using a material of 509 training cases and 104 test cases, the performance of the system, measured as the area under the ROC curve, was 0.86 in the test group. It is concluded that a completely automatic method can be used for interpretation of V-P scintigrams. It is faster and more robust than a previously presented method [4,5] and the accuracy is at the same level as the the previous method. It also handles abnormalities in the lungs.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Lungmedicin och allergi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Respiratory Medicine and Allergy (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy