IMRT treatment planning - A comparative inter-system and intor-centre planning exercise of the ESTRO QUASIMODO group
-
Bohsung, J (författare)
-
Gillis, S (författare)
-
Arrans, R (författare)
-
visa fler...
-
Bakai, A (författare)
-
De Wagter, C (författare)
-
- Knöös, Tommy (författare)
- Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
-
Mijnheer, BJ (författare)
-
Paiusco, M (författare)
-
Perrin, BA (författare)
-
Welleweerd, H (författare)
-
Williams, P (författare)
-
visa färre...
-
(creator_code:org_t)
- Elsevier BV, 2005
- 2005
- Engelska.
-
Ingår i: Radiotherapy and Oncology. - : Elsevier BV. - 1879-0887 .- 0167-8140. ; 76:3, s. 354-361
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Background and purpose: The purpose of this work was a comparison of realistic IMRT plans based on the same CT-image data set and a common predefined set of dose objectives for the planning target volume and the organs at risk. This work was part of the larger European QUASIMODO IMRT verification project. Materials and methods: Eleven IMRT. plans were produced by nine different European groups, each applying a representative set of. clinically used IMRT treatment planning systems. The plans produced were to be deliverable in a clinically acceptable treatment time with the local technical equipment. All plans were characterized using a set of different quality measures such as dose-volume histograms, number of monitor units and treatment time. Results: Only one plan was able to fulfil all dose objectives strictly; six plans failed some of the objectives but were still considered to be clinically acceptable; four plans were not able to reach the objectives. Additional quality scores such as the number of monitor units and treatment time showed large variations, which mainly depend on the delivery technique. Conclusion: The presented planning study showed that with nearly all presently available IMRT planning and delivery systems comparable dose distributions could be achieved if the planning goals are clearly defined in advance.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
Nyckelord
- intensity-modulated radiation therapy
- treatment planning
- multi-centre
- intercomparison
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas
- Av författaren/redakt...
-
Bohsung, J
-
Gillis, S
-
Arrans, R
-
Bakai, A
-
De Wagter, C
-
Knöös, Tommy
-
visa fler...
-
Mijnheer, BJ
-
Paiusco, M
-
Perrin, BA
-
Welleweerd, H
-
Williams, P
-
visa färre...
- Om ämnet
-
- MEDICIN OCH HÄLSOVETENSKAP
-
MEDICIN OCH HÄLS ...
-
och Klinisk medicin
-
och Radiologi och bi ...
- Artiklar i publikationen
-
Radiotherapy and ...
- Av lärosätet
-
Lunds universitet