SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:lup.lub.lu.se:9f884296-d5ea-4ce9-92da-dda18d73fa95"
 

Sökning: onr:"swepub:oai:lup.lub.lu.se:9f884296-d5ea-4ce9-92da-dda18d73fa95" > Detection of cardia...

Detection of cardiac pathology: time intervals and spectral analysis.

El-Segaier, Milad (författare)
Lund University,Lunds universitet,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Pesonen, Erkki (författare)
Lund University,Lunds universitet,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Lukkarinen, Sakari (författare)
visa fler...
Peters, Kristoffer (författare)
Lund University,Lunds universitet,Statistiska institutionen,Ekonomihögskolan,Department of Statistics,Lund University School of Economics and Management, LUSEM
Sörnmo, Leif (författare)
Lund University,Lunds universitet,Institutionen för elektro- och informationsteknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Electrical and Information Technology,Departments at LTH,Faculty of Engineering, LTH
Sepponen, Raimo (författare)
visa färre...
 (creator_code:org_t)
2007-05-24
2007
Engelska.
Ingår i: Acta Pædiatrica. - : Wiley. - 1651-2227 .- 0803-5253. ; 96:7, s. 1036-1042
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • AIM: To develop an objective diagnostic method that facilitates detection of noncyanotic congenital heart diseases. METHODS: Heart sounds and murmurs were recorded from 60 healthy children and 173 children with noncyanotic congenital heart disease. Time intervals were measured and spectrum of the systolic murmurs analyzed. Stepwise logistic regression analysis was used to distinguish physiological from pathological signals. The receiver operating characteristic (ROC) curve was plotted to show the classification performance of the model and the area under the curve (AUC) was calculated. The probability cut-off points for calculation of sensitivities and specificities were estimated. RESULTS: The distinguishing variables were the interval from the end of the first heart sound (S(1)) and the beginning of the systolic murmur, respiratory variation of the splitting of the second heart sound, intensity of the systolic murmur, and standard deviation of the interval from the end of the S(1) to the maximum intensity of the murmur. The AUC was 0.95, indicating an excellent classification performance of the model. The sensitivity of 95% and specificity of 72% was achieved at a probability cut-off point of 0.45. Significant cardiac defects were correctly classified. CONCLUSION: Interval measurements and spectral analysis can be used to confirm significant noncyanotic congenital heart diseases. Further development of the method is necessary to detect also insignificant heart defects.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Pediatrik (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Pediatrics (hsv//eng)

Nyckelord

receiver operating characteristic curve
murmur classification
heart sounds
stepwise logistic
signal analysis
regression analysis

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy