Sökning: onr:"swepub:oai:lup.lub.lu.se:c3f69179-f6a3-4bef-9c15-4de68c9b8c01" >
Reversed phase cont...
Reversed phase continuous full filling CEC-ESI-MS
-
- Viberg, Peter (författare)
- Lund University,Lunds universitet,Centrum för analys och syntes,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Centre for Analysis and Synthesis,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
-
- Spégel, Peter (författare)
- Lund University,Lunds universitet,Centrum för analys och syntes,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Centre for Analysis and Synthesis,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
-
Nilsson, J. (författare)
-
visa fler...
-
Petersson, P. (författare)
-
Joernten-Karlsson, M. (författare)
-
Nilsson, S. (författare)
-
visa färre...
-
(creator_code:org_t)
- 2007-01-16
- 2007
- Engelska.
-
Ingår i: Chromatographia. - : Springer Science and Business Media LLC. - 0009-5893 .- 1612-1112. ; 65:5-6, s. 291-297
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Nanoparticles were used as a pseudostationary phase in capillary electrochromatography (CEC) electrospray ionisation-mass spectrometry (ESI-MS) for separation of both neutral analytes by a reversed phase mechanism, as well as for cationic analytes by a cation exchange mechanism. Nanoparticles suspended in electrolyte, were injected as a plug prior to the sample using a partial filling technique (PF), or used as electrolyte in a continuous full filling (CFF) technique. An orthogonal ESI probe was used to hinder the nanoparticles from entering the mass spectrometer and to allow detection of analytes co-eluting with concentrated nanoparticle slurries. Two types of nanoparticles were synthesised and used, both of them having a hydrophobic core and a hydrophilic surface. The hydrophobic core gave the nanoparticles reversed phase properties and the hydrophilic surface promoted the formation of stable slurries of nanoparticles in electrolytes with a low concentration of organic modifier. The surface of one of the nanoparticle types was covered with sulphate groups that, besides from enhancing slurry stability and thus enabling reversed phase CEC, also enabled ion exchange CEC. Both nanoparticle types showed reproducible and interpretable retention properties.
Ämnesord
- NATURVETENSKAP -- Kemi (hsv//swe)
- NATURAL SCIENCES -- Chemical Sciences (hsv//eng)
Nyckelord
- pseudostationary phase
- nanoparticles
- spectrometry
- capillary electrochromatography
- electrospray ionisation-mass
- partial filling
- continuous full filling
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas