Sökning: onr:"swepub:oai:lup.lub.lu.se:cb205f05-8cdb-4a79-8132-308b8bf0f5f1" >
Immunoassay-based q...
Immunoassay-based quantification of full-length peptidylglycine alpha-amidating monooxygenase in human plasma
-
- Ilina, Yulia (författare)
- PAM Theragnostics GmbH
-
- Kaufmann, Paul (författare)
- PAM Theragnostics GmbH
-
- Melander, Olle (författare)
- Lund University,Lunds universitet,Kardiovaskulär forskning - hypertoni,Forskargrupper vid Lunds universitet,Cardiovascular Research - Hypertension,Lund University Research Groups,Skåne University Hospital
-
visa fler...
-
- Press, Michaela (författare)
- PAM Theragnostics GmbH
-
- Thuene, Katrin (författare)
- PAM Theragnostics GmbH
-
- Bergmann, Andreas (författare)
- PAM Theragnostics GmbH
-
visa färre...
-
(creator_code:org_t)
- 2023
- 2023
- Engelska.
-
Ingår i: Scientific Reports. - 2045-2322. ; 13:1
- Relaterad länk:
-
http://dx.doi.org/10... (free)
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- A one-step sandwich chemiluminescence immunometric assay (LIA) was developed for the quantification of bifunctional peptidylglycine-α-amidating monooxygenase (PAM) in human plasma (PAM-LIA). PAM is responsible for the activation of more than half of known peptide hormones through C-terminal α-amidation. The assay employed antibodies targeting specific catalytic PAM-subunits, peptidylglycine alpha-hydroxylating monooxygenase (PHM) and peptidyl-alpha-hydroxyglycine alpha-amidating lyase (PAL), to ensure detection of full-length PAM. The PAM-LIA assay was calibrated with a human recombinant PAM enzyme and achieved a detection limit of 189 pg/mL and a quantification limit of 250 pg/mL. The assay demonstrated good inter-assay (6.7%) and intra-assay (2.2%) variabilities. It exhibited linearity when accessed by gradual dilution or random mixing of plasma samples. The accuracy of the PAM-LIA was determined to be 94.7% through spiking recovery experiments, and the signal recovery after substance interference was 94–96%. The analyte showed 96% stability after six freeze–thaw cycles. The assay showed strong correlation with matched EDTA and serum samples, as well as matched EDTA and Li-Heparin samples. Additionally, a high correlation was observed between α-amidating activity and PAM-LIA. Finally, the PAM-LIA assay was successfully applied to a sub-cohort of a Swedish population-based study, comprising 4850 individuals, confirming its suitability for routine high throughput screening.
Ämnesord
- NATURVETENSKAP -- Kemi -- Analytisk kemi (hsv//swe)
- NATURAL SCIENCES -- Chemical Sciences -- Analytical Chemistry (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Klinisk laboratoriemedicin (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Clinical Laboratory Medicine (hsv//eng)