SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:lup.lub.lu.se:d5400ce3-5dd1-493d-92de-ca52f9a46009"
 

Sökning: onr:"swepub:oai:lup.lub.lu.se:d5400ce3-5dd1-493d-92de-ca52f9a46009" > Radiopaque dyes all...

Radiopaque dyes allow vessel imaging in lung tissue using laboratory phase contrast micro-CT

Dreier, Till (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,LTH profilområde: Teknik för hälsa,LTH profilområden,Lunds Tekniska Högskola,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,LTH Profile Area: Engineering Health,LTH Profile areas,Faculty of Engineering, LTH
Bernström, Gustaf (författare)
Lund University
Ganji, Sahel (författare)
Lund University
visa fler...
Norvik, Christian (författare)
Lund University,Lunds universitet,Kärlväggsbiologi,Forskargrupper vid Lunds universitet,Vessel Wall Biology,Lund University Research Groups
Tran Lundmark, Karin (författare)
Lund University,Lunds universitet,Kärlväggsbiologi,Forskargrupper vid Lunds universitet,WCMM- Wallenberg center för molekylär medicinsk forskning,Medicinska fakulteten,Vessel Wall Biology,Lund University Research Groups,WCMM-Wallenberg Centre for Molecular Medicine,Faculty of Medicine,Skåne University Hospital
Bech, Martin (författare)
Lund University,Lunds universitet,X-ray Phase Contrast,Forskargrupper vid Lunds universitet,LTH profilområde: Teknik för hälsa,LTH profilområden,Lunds Tekniska Högskola,Lund University Research Groups,LTH Profile Area: Engineering Health,LTH Profile areas,Faculty of Engineering, LTH
Müller, Bert (redaktör/utgivare)
Wang, Ge (redaktör/utgivare)
visa färre...
 (creator_code:org_t)
SPIE, 2022
2022
Engelska.
Ingår i: Proceedings of SPIE - The International Society for Optical Engineering. - : SPIE. ; 12242
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • Phase contrast micro-CT is a powerful technique allowing imaging of soft tissue at synchrotrons or using lab- oratory sources. The use of contrast agents is a useful approach when imaging vascular structures. However, common x-ray contrast agents typically rely on heavy metals to increase absorption, which may affect the phase contrast and cause artifacts in the reconstructed volumes. Thus, utilizing an agent with lower attenuation similar to soft tissue is clearly advantageous. Here, we evaluated different colored radiopaque solutions (tissue marking dyes) which had been injected into the vascular system of bovine lung samples, prior to embedding in paraffin. Scans were performed using a micro-focus x-tube calibrated to 10 µm spot size at 70 kV and a photon counting detector with a silicon sensor and 75 µm pixels. The resulting volumes have a voxel size of (25 µm)3, limited by the size of the samples, but sufficient to resolve the vascular system. Experiments confirmed that sufficient perfusion of the vessels with the dyes could be achieved, and the different dyes could be clearly discerned in the reconstructed volumes without causing artifacts allowing to clearly identify features in the soft tissue. Further, the findings were confirmed by histology.Keywords:

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy