Revolving permanent magnet causes rotating particle motion that makes new detection schemes possible in magnetomotive ultrasound

Evertsson, Maria (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Medicinskt ultraljud,Forskargrupper vid Lunds universitet,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH,Medical ultrasound,Lund University Research Groups
Sjostrand, Sandra (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
Erlov, Tobias (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
visa fler...
Svensson, Ingrid (författare)
Lund University,Lunds universitet,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
Andersson, Roger (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
Cinthio, Magnus (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
Jansson, Tomas (författare)
Lund University,Lunds universitet,Medicinskt ultraljud,Forskargrupper vid Lunds universitet,Medicon Bridge,Medical ultrasound,Lund University Research Groups,Region Skåne
visa färre...
 (creator_code:org_t)
2019
2019
Engelska 3 s.
Ingår i: 2019 IEEE International Ultrasonics Symposium, IUS 2019. - 1948-5727 .- 1948-5719. - 9781728145976 - 9781728145969 ; 2019-October, s. 2373-2375
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • Magnetomotive ultrasound, MMUS, can reveal the presence of a magnetic contrast agent by applying an external magnetic field. If the interaction between the agent and the field is strong enough, a movement that can be detected by ultrasound is induced in the surrounding tissue, thereby inferring the contrast agent distribution. Electromagnets have been used to generate the necessary magnetic field, but due to their size, weight, and propensity to heat up, they are impractical to work with. Furthermore, the resulting magnetic force is directed mainly along the symmetry axis of such magnets, and thus the resulting movement is primarily a one-dimensional oscillation. We suggest the use of a rotating permanent magnet that generates a two-dimensional particle motion, and that this makes new detection schemes for MMUS possible. A prototype probe, containing a rotating neodymium magnet, was used to move a metallic sphere embedded in tissue-mimicking material. Cine loops recorded any in-plane movement with the magnetic probe placed in two different positions. A two-dimensional movement was demonstrated, using both our previously developed MMUS algorithm as well as a phase-based motion tracking algorithm. The conventional 1D MMUS processing detected the axial component in both magnetic probe positions, whereas the two-dimensional motion tracking algorithm estimated a rotational motion from the same measurements. The added dimension of motion could engender possibilities to more precise signal processing and thus improve robustness of magnetomotive motion detection. Moreover, the incorporation of a permanent magnet makes for a more practical device, as compared to using electromagnets.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Signalbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Signal Processing (hsv//eng)

Nyckelord

2D
Magnetomotive
motion tracking
permanent
rotating

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy