Sökning: onr:"swepub:oai:lup.lub.lu.se:e79d4694-92ca-4b52-8b79-97b9b74b09a2" >
Quantitative X-ray ...
Quantitative X-ray phase-contrast microtomography from a compact laser-driven betatron source.
-
Wenz, J (författare)
-
Schleede, S (författare)
-
Khrennikov, K (författare)
-
visa fler...
-
- Bech, Martin (författare)
- Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
-
Thibault, P (författare)
-
Heigoldt, M (författare)
-
Pfeiffer, F (författare)
-
Karsch, S (författare)
-
visa färre...
-
(creator_code:org_t)
- 2015-07-20
- 2015
- Engelska.
-
Ingår i: Nature Communications. - : Springer Science and Business Media LLC. - 2041-1723. ; 6
- Relaterad länk:
-
http://www.ncbi.nlm.... (free)
-
visa fler...
-
http://dx.doi.org/10... (free)
-
https://www.nature.c...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- X-ray phase-contrast imaging has recently led to a revolution in resolving power and tissue contrast in biomedical imaging, microscopy and materials science. The necessary high spatial coherence is currently provided by either large-scale synchrotron facilities with limited beamtime access or by microfocus X-ray tubes with rather limited flux. X-rays radiated by relativistic electrons driven by well-controlled high-power lasers offer a promising route to a proliferation of this powerful imaging technology. A laser-driven plasma wave accelerates and wiggles electrons, giving rise to a brilliant keV X-ray emission. This so-called betatron radiation is emitted in a collimated beam with excellent spatial coherence and remarkable spectral stability. Here we present a phase-contrast microtomogram of a biological sample using betatron X-rays. Comprehensive source characterization enables the reconstruction of absolute electron densities. Our results suggest that laser-based X-ray technology offers the potential for filling the large performance gap between synchrotron- and current X-ray tube-based sources.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas