Sökning: onr:"swepub:oai:research.chalmers.se:64e6563a-b2be-4bbb-a2c4-2d736258c7c0" >
On the use of CR-39...
On the use of CR-39 PNTD with AFM analysis in measuring proton-induced target fragmentation particles
-
Kodaira, S. (författare)
-
Konishi, T. (författare)
-
Kitamura, H. (författare)
-
visa fler...
-
Kurano, M. (författare)
-
Kawashima, H. (författare)
-
Uchihori, Yukio (författare)
-
Nishio, T. (författare)
-
- Yasuda, N. (författare)
- University of Fukui
-
- Ogura, K. (författare)
- Nihon University
-
- Sihver, Lembit, 1962 (författare)
- Chalmers tekniska högskola,Chalmers University of Technology
-
- Benton, E. R. (författare)
- Oklahoma State University
-
visa färre...
-
(creator_code:org_t)
- Elsevier BV, 2015
- 2015
- Engelska.
-
Ingår i: Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms. - : Elsevier BV. - 0168-583X. ; 349, s. 163-168
- Relaterad länk:
-
https://doi.org/10.1...
-
visa fler...
-
https://research.cha...
-
visa färre...
Abstract
Ämnesord
Stäng
- In addition to energy loss by ionization process, protons of energy >similar to 50 MeV, such as those used in proton radiotherapy, can undergo nuclear interactions with nuclei of Z > 1, resulting in the production, of short range (<20 gm), high-LET (linear energy transfer) target fragment particles. One of the few methods to detect these short-range particles is by means of CR-39 plastic nuclear track detector (PNTD) analyzed with an atomic force microscope (AFM). However, due to the LET-dependent angular sensitivity of CR-39 PNTD, multiple detectors exposed at a range of incident angles to the primary proton beam, must be analyzed in order to accurately determine the LET spectrum, absorbed dose and dose equivalent. The LET spectrum of 160 MeV proton-induced secondary particles was experimentally measured with CR-39 PNTDs, which were exposed at six different incident angles to take into account the intrinsic sensitivity of the critical angle for track registration. The irradiated detectors were chemically processed to remove a 1 gm thick volume of CR-39 PNTD. The measured LET range of short range tracks was from 15 key/mu m up to 1.5 MeV/mu m. The absorbed dose contribution (D-s/D-p) from secondary particles to primary proton dose was similar to 1%, while the dose equivalent contribution (H-s/D-p) was found to be similar to 20%. Analysis of CR-39 PNTD by AFM yielded similar to 60% higher value for absorbed dose compared to standard optical microscopy analysis.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Maskinteknik -- Produktionsteknik, arbetsvetenskap och ergonomi (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Mechanical Engineering -- Production Engineering, Human Work Science and Ergonomics (hsv//eng)
Nyckelord
- Biological Effectiveness
- Secondary particles
- Nuclear Track Detector
- CR-39
- Proton therapy
- Target fragmentation
- AFM
- Charged-Particles
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas
- Av författaren/redakt...
-
Kodaira, S.
-
Konishi, T.
-
Kitamura, H.
-
Kurano, M.
-
Kawashima, H.
-
Uchihori, Yukio
-
visa fler...
-
Nishio, T.
-
Yasuda, N.
-
Ogura, K.
-
Sihver, Lembit, ...
-
Benton, E. R.
-
visa färre...
- Om ämnet
-
- TEKNIK OCH TEKNOLOGIER
-
TEKNIK OCH TEKNO ...
-
och Maskinteknik
-
och Produktionstekni ...
- Artiklar i publikationen
-
Nuclear Instrume ...
- Av lärosätet
-
Chalmers tekniska högskola