SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:research.chalmers.se:77b7f8d5-675e-43ae-8fe4-b7f68a78a3ff"
 

Sökning: onr:"swepub:oai:research.chalmers.se:77b7f8d5-675e-43ae-8fe4-b7f68a78a3ff" > Factors affecting t...

Factors affecting the numerical response and fracture location of the GHBMC M50 rib in dynamic anterior-posterior loading

Rampersadh, Claire (författare)
University of Waterloo
Agnew, Amanda (författare)
Ohio State University
Malcolm, Skye (författare)
visa fler...
Gierczycka, Donata (författare)
University of Waterloo
Iraeus, Johan, 1973 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Cronin, Duane (författare)
University of Waterloo
visa färre...
 (creator_code:org_t)
Elsevier BV, 2022
2022
Engelska.
Ingår i: Journal of the Mechanical Behavior of Biomedical Materials. - : Elsevier BV. - 1751-6161 .- 1878-0180. ; 136
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Rib fractures are common traumatic injuries, with links to increased morbidity and mortality. Finite element ribs from human body models have struggled to predict the force-displacement response, force and displacement at fracture, and the fracture location for isolated rib tests. In the current study, the sensitivity of a human body model rib with updated anisotropic and asymmetric material models to changes in boundary conditions, material properties, and geometry was investigated systematically to quantify contributions to response. The updated material models using uncalibrated average material properties from literature improved the force-displacement response of the model, whereas the cross-sectional geometry was the only parameter to effect fracture location. The resulting uncalibrated model with improved material models and cross-sectional geometry closely predicted experimental average force-displacement response and fracture location.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)
NATURVETENSKAP  -- Kemi -- Annan kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Other Chemistry Topics (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi -- Biomaterialvetenskap (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology -- Biomaterials Science (hsv//eng)

Nyckelord

Thoracic injury
Rib fracture
Human body model
Finite element model

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy