Sökning: onr:"swepub:oai:research.chalmers.se:8d76bcdc-24c8-47c9-b2ec-35ceee891881" > Part-Load Performan...

Part-Load Performance of a Wet Indirectly Fired Gas Turbine Integrated with an Organic Rankine Cycle Turbogenerator

Pierobon, L. (författare)
Danmarks Tekniske Universitet,Technical University of Denmark
Nguyen, Tuong-Van, 1988 (författare)
Danmarks Tekniske Universitet,Technical University of Denmark
Mazzucco, A. (författare)
Danmarks Tekniske Universitet,Technical University of Denmark
visa fler...
Larsen, Ulrik, 1972 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Haglind, F. (författare)
Danmarks Tekniske Universitet,Technical University of Denmark
visa färre...
 (creator_code:org_t)
2014-12-11
2014
Engelska.
Ingår i: Energies. - : MDPI AG. - 1996-1073 .- 1996-1073. ; 7:12, s. 8294-8316
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Over the last years, much attention has been paid to the development of efficient and low-cost power systems for biomass-to-electricity conversion. This paper aims at investigating the design-and part-load performance of an innovative plant based on a wet indirectly fired gas turbine (WIFGT) fueled by woodchips and an organic Rankine cycle (ORC) turbogenerator. An exergy analysis is performed to identify the sources of inefficiencies, the optimal design variables, and the most suitable working fluid for the organic Rankine process. This step enables to parametrize the part-load model of the plant and to estimate its performance at different power outputs. The novel plant has a nominal power of 250 kW and a thermal efficiency of 43%. The major irreversibilities take place in the burner, recuperator, compressor and in the condenser. Toluene is the optimal working fluid for the organic Rankine engine. The part-load investigation indicates that the plant can operate at high efficiencies over a wide range of power outputs (50%-100%), with a peak thermal efficiency of 45% at around 80% load. While the ORC turbogenerator is responsible for the efficiency drop at low capacities, the off-design performance is governed by the efficiency characteristics of the compressor and turbine serving the gas turbine unit.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Energiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Energy Engineering (hsv//eng)

Nyckelord

part-load
gas turbine
organic Rankine cycle (ORC)
biomass
exergy

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

  • Energies (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Pierobon, L.
Nguyen, Tuong-Va ...
Mazzucco, A.
Larsen, Ulrik, 1 ...
Haglind, F.
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Maskinteknik
och Energiteknik
Artiklar i publikationen
Energies
Av lärosätet
Chalmers tekniska högskola

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy