Sökning: onr:"swepub:oai:research.chalmers.se:bd67d27c-f2dd-4913-998e-9cac2c8a675e" >
Evaluation of a fin...
-
Shirvany, Yazdan,1980Chalmers tekniska högskola,Chalmers University of Technology
(författare)
Evaluation of a finite-element reciprocity method for epileptic EEG source localization: Accuracy, computational complexity and noise robustness
- Artikel/kapitelEngelska2013
Förlag, utgivningsår, omfång ...
-
2013-04-14
-
Springer Science and Business Media LLC,2013
Nummerbeteckningar
-
LIBRIS-ID:oai:research.chalmers.se:bd67d27c-f2dd-4913-998e-9cac2c8a675e
-
https://research.chalmers.se/publication/191808URI
-
https://doi.org/10.1007/s13534-013-0083-1DOI
Kompletterande språkuppgifter
-
Språk:engelska
-
Sammanfattning på:engelska
Ingår i deldatabas
Klassifikation
-
Ämneskategori:art swepub-publicationtype
-
Ämneskategori:ref swepub-contenttype
Anmärkningar
-
PURPOSEThe aim of this paper is to evaluate the performance of an EEG source localization method that combines a finite element method (FEM) and the reciprocity theorem.METHODSThe reciprocity method is applied to solve the forward problem in a four-layer spherical head model for a large number of test dipoles. To benchmark the proposed method, the results are compared with an analytical solution and two state-of-the-art methods from the literature. Moreover, the dipole localization error resulting from utilizing the method in the inverse procedure for a realistic head model is investigated with respect to EEG signal noise and electrode misplacement.RESULTSThe results show approximately 3% relative error between numerically calculated potentials done by the reciprocity theorem and the analytical solutions. When adding EEG noise with SNR between 5 and 10, the mean localization error is approximately 4.3 mm. For the case with 10 mm electrode misplacement the localization error is 4.8 mm. The reciprocity EEG source localization speeds up the solution of the inverse problem with more than three orders of magnitude compared to the state-of-the-art methods.CONCLUSIONSThe reciprocity method has high accuracy for modeling the dipole in EEG source localization, is robust with respect to noise, and faster than alternative methods.
Ämnesord och genrebeteckningar
Biuppslag (personer, institutioner, konferenser, titlar ...)
-
Rubaek, Tonny,1979Chalmers tekniska högskola,Chalmers University of Technology(Swepub:cth)rubaek
(författare)
-
Edelvik, Fredrik,1972
(författare)
-
Jakobsson, Stefan
(författare)
-
Talcoth, Oskar,1980Chalmers tekniska högskola,Chalmers University of Technology(Swepub:cth)talcoth
(författare)
-
Persson, Mikael,1959Chalmers tekniska högskola,Chalmers University of Technology(Swepub:cth)elfmp
(författare)
-
Chalmers tekniska högskola
(creator_code:org_t)
Sammanhörande titlar
-
Ingår i:Biomedical Engineering Letters: Springer Science and Business Media LLC3:1, s. 8-162093-985X2093-9868
Internetlänk
Hitta via bibliotek
Till lärosätets databas