SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:research.chalmers.se:c1b680ec-1252-4f80-a35d-d98a38f1cabe"
 

Sökning: onr:"swepub:oai:research.chalmers.se:c1b680ec-1252-4f80-a35d-d98a38f1cabe" > Micromotion minimiz...

  • Higgins, Gerard,1989Stockholms universitet,Fysikum,Chalmers University of Technology, Sweden,Chalmers tekniska högskola,Stockholm University (författare)

Micromotion minimization using Ramsey interferometry

  • Artikel/kapitelEngelska2021

Förlag, utgivningsår, omfång ...

  • 2021-12-16
  • IOP Publishing,2021
  • electronicrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:research.chalmers.se:c1b680ec-1252-4f80-a35d-d98a38f1cabe
  • https://research.chalmers.se/publication/527952URI
  • https://doi.org/10.1088/1367-2630/ac3db6DOI
  • https://urn.kb.se/resolve?urn=urn:nbn:se:su:diva-200886URI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:art swepub-publicationtype
  • Ämneskategori:ref swepub-contenttype

Anmärkningar

  • We minimize the stray electric field in a linear Paul trap quickly and accurately, by applying interferometry pulse sequences to a trapped ion optical qubit. The interferometry sequences are sensitive to the change of ion equilibrium position when the trap stiffness is changed, and we use this to determine the stray electric field. The simplest pulse sequence is a two-pulse Ramsey sequence, and longer sequences with multiple pulses offer a higher precision. The methods allow the stray field strength to be minimized beyond state-of-the-art levels. Using a sequence of nine pulses we reduce the 2D stray field strength to (10.5 +/- 0.8) mV m(-1) in 11 s measurement time. The pulse sequences are easy to implement and automate, and they are robust against laser detuning and pulse area errors. We use interferometry sequences with different lengths and precisions to measure the stray field with an uncertainty below the standard quantum limit. This marks a real-world case in which quantum metrology offers a significant enhancement. Also, we minimize micromotion in 2D using a single probe laser, by using an interferometry method together with the resolved sideband method; this is useful for experiments with restricted optical access. Furthermore, a technique presented in this work is related to quantum protocols for synchronizing clocks; we demonstrate these protocols here.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Salim, ShalinaStockholms universitet,Fysikum,Stockholm University(Swepub:su)shsa7316 (författare)
  • Zhang, ChiStockholms universitet,Fysikum,Imperial College of Science, Technology and Medicine,Stockholm University(Swepub:su)chizh (författare)
  • Parke, HarryStockholms universitet,Fysikum,Stockholm University(Swepub:su)hapa3074 (författare)
  • Pokorny, FabianStockholms universitet,Fysikum,University Of Oxford,Stockholm University (författare)
  • Hennrich, MarkusStockholms universitet,Fysikum,Stockholm University(Swepub:su)mhenn (författare)
  • Stockholms universitetFysikum (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:New Journal of Physics: IOP Publishing23:121367-2630

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy