SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:research.chalmers.se:d5129053-2aa9-4c28-b7fb-f860c4acd392"
 

Sökning: onr:"swepub:oai:research.chalmers.se:d5129053-2aa9-4c28-b7fb-f860c4acd392" > A high-throughput m...

A high-throughput method for liquid chromatography-tandem mass spectrometry determination of plasma alkylresorcinols, biomarkers of whole grain wheat and rye intake.

Ross, Alastair, 1976 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Svelander, Cecilia, 1980 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Savolainen, Otto, 1982 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
visa fler...
Vendelbo Lind, Mads, 1988 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Kirwan, J.P. (författare)
Cleveland Clinic Foundation
Breton, I. (författare)
Nestle S.A.
Godin, J. P. (författare)
Nestle S.A.
Sandberg, Ann-Sofie, 1951 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
visa färre...
 (creator_code:org_t)
Elsevier BV, 2016
2016
Engelska.
Ingår i: Analytical Biochemistry. - : Elsevier BV. - 0003-2697 .- 1096-0309. ; 499, s. 1-7
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Plasma alkylresorcinols are increasingly analyzed in cohort studies to improve estimates of whole grain intake and their relationship with disease incidence. Current methods require large volumes of solvent (>10 ml/sample) and have relatively low daily sample throughput. We tested five different supported extraction methods for extracting alkylresorcinols from plasma and improved a normal-phase liquid chromatography coupled to a tandem mass spectrometer method to reduce sample analysis time. The method was validated and compared with gas chromatography-mass spectrometry analysis. Sample preparation with HybridSPE supported extraction was most effective for alkylresorcinol extraction, with recoveries of 77-82% from 100 μl of plasma. The use of 96-well plates allowed extraction of 160 samples per day. Using a 5-cm NH2 column and heptane reduced run times to 3 min. The new method had a limit of detection and limit of quantification equivalent to 1.1-1.8 nmol/L and 3.5-6.1 nmol/L plasma, respectively, for the different alkylresorcinol homologues. Accuracy was 93-105%, and intra- and inter-batch precision values were 4-18% across different plasma concentrations. This method makes it possible to quantify plasma alkylresorcinols in 100 μl of plasma at a rate of at least 160 samples per day without the need for large volumes of organic solvents.

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Näringslära (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Nutrition and Dietetics (hsv//eng)

Nyckelord

whole grain
Alkylresorcinols
intake
Plasma biomarkers

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy