SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:1525 2167 "

Sökning: L773:1525 2167

  • Resultat 1-10 av 58
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  •  
4.
  •  
5.
  •  
6.
  • Bajraktari, Gani, et al. (författare)
  • Prolonged total isovolumic time predicts cardiac events following coronary artery bypass surgery
  • 2008
  • Ingår i: European Journal of Echocardiography. - : Oxford University Press. - 1525-2167 .- 1532-2114. ; 9:6, s. 779-783
  • Tidskriftsartikel (refereegranskat)abstract
    • AIMS: Left ventricular (LV) systolic dysfunction may be associated with compromised stroke volume, which may be caused by asynchrony, reflected on the prolongation of isovolumic time (t-IVT). To assess the prognostic role of Doppler echocardiographic measurements in predicting cardiac events after coronary artery bypass grafting (CABG).METHODS AND RESULTS: The study included 74 patients undergoing routine CABG. A pre-CABG Doppler echocardiographic assessment of LV dimensions, filling and ejection was performed and t-IVT was determined as [60 - (total ejection time + total filling time)]. Follow-up period was 18 +/- 12 months. Of the 74 patients (age 65 +/- 16 years, 59 males), 29 underwent hospital admission for a cardiac event or died. There were no differences in age, gender, incidence of previous infarct or mitral regurgitation, LV-EDD (left ventricular end-diastolic dimension), left atrial or right ventricular size in patients with cardiac events compared with those without events. Left ventricular end-systolic dimension (LV-ESD) was greater (4.5 +/- 0.9 vs. 3.9 +/- 0.9 cm, P = 0.003), fractional shortening (FS) was lower (21 +/- 4 vs. 32 +/- 8%), E:A ratio and Tei index were higher (2.1 +/- 0.8 vs. 1.0 +/- 0.6 and 0.9 +/- 0.3 vs. 0.6 +/- 0.3, all P < 0.001), and t-IVT was longer (16 +/- 5 vs.10 +/- 4 s/min, P < 0.001) in patients with events. Multivariate predictors of post-CABG events (odds ratio 95% confidence interval) were low FS [0.66 (0.50-0.87), P < 0.001], high E:A ratio [l4.13 (1.17-14.60), P = 0.028], large LV-ESD [0.19 (0.05-0.84), P = 0.029], and long t-IVT [1.37 (1.02-1.84), P = 0.035].CONCLUSION: Despite satisfactory surgical revascularization, long t-IVT and systolic dysfunction suggest persistent ventricular dyssynchrony that contributes to post-CABG cardiac events. Early assessment of such patients for potential benefit from electrical resynchronization may optimize their cardiac performance and hence clinical outcome.
  •  
7.
  • Bech-Hanssen, Odd, 1956, et al. (författare)
  • The relative contribution of prosthetic gradients, systemic arterial pressure, and pulse pressure to the left ventricular pressure in patients with aortic prosthetic valves.
  • 2011
  • Ingår i: European journal of echocardiography. - : Oxford University Press (OUP). - 1532-2114 .- 1525-2167. ; 12:1, s. 37-45
  • Tidskriftsartikel (refereegranskat)abstract
    • AIMS: Aortic valve replacement (AVR) in patients with aortic stenosis reduces the left ventricular (LV) pressure and the LV mass. However, residual LV hypertrophy at follow-up is a common finding with negative prognostic impact. In the present study, we investigate the contribution of the prosthesis (size, type, and gradients) and the load opposed by the arterial system to the mean LV pressure (MLVP). METHODS AND RESULTS: Twenty-five patients with a bileaflet mechanical (n = 12, size 19-27) or stented biological (size 21-25) valve were included. After weaning from bypass, continuous Doppler recordings (transoesophageal transducer) and simultaneous LV and aortic pressure measurements were performed (high-fidelity catheters). The mean prosthesis gradients with catheter or Doppler were moderately correlated to MLVP (R(2) = 0.40 and 0.34, P = 0.002 and <0.0001). In a multiple regression model, the relationship between MLVP and prosthesis gradient, mean blood pressure, and pulse pressure was strong for both mechanical and biological valves. Using catheter prosthesis gradients, we could explain 97% of the variability in MLVP and when using Doppler gradients 91%. CONCLUSION: In the present study of patients with aortic prosthetic valves, we demonstrate the importance of the load opposed by the arterial system for the LV pressure. Our findings suggest that the MLVP can be estimated from easily obtainable Doppler data and blood pressure measurements. In analysing predictors of LV mass regression, morbidity, and mortality following AVR, the equations might be of interest.
  •  
8.
  • Bjällmark, Anna, et al. (författare)
  • Ultrasonographic strain imaging is superior to conventional non-invasive measures of vascular stiffness in the detection of age-dependent differences in the mechanical properties of the common carotid artery
  • 2010
  • Ingår i: European Journal of Echocardiography. - : Oxford University Press (OUP). - 1525-2167 .- 1532-2114. ; 11:7, s. 630-636
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims: Elastic properties of large arteries have been shown to deteriorate with age and in the presence of atherosclerotic vascular disease. In this study, the performance of ultrasonographic strain measurements was compared to conventional measures of vascular stiffness in the detection of age-dependent differences in the elastic properties of the common carotid artery.Methods and results: In 10 younger (25-28 years, 4 women) and 10 older (50-59 years, 4 women) healthy individuals, global and regional circumferential and radial strain variables were measured in the short-axis view of the right common carotid artery using ultrasonographic two-dimensional (2D) strain imaging with recently introduced speckle tracking technique. Conventional elasticity variables, elastic modulus (Ep) and β stiffness index, were calculated using M-mode sonography and non-invasive blood pressure measurements. Global and regional circumferential systolic strain and strain rate values were significantly higher (p < 0.001, p < 0.01 for regional late systolic strain rate) in the younger individuals, whereas the values of conventional elasticity variables in the same group were lower (p < 0.05). Among all strain and conventional elasticity variables, principal component analysis and its regression extension identified only circumferential systolic strain variables as contributing significantly to the observed discrimination between the younger and older age groups.Conclusion: Ultrasonographic 2D-strain imaging is a sensitive method for the assessment of elastic properties in the common carotid artery, being in this respect superior to conventional measures of vascular elasticity. The method has potential to become a valuable non-invasive tool in the detection of early atherosclerotic vascular changes.
  •  
9.
  • Bukachi, Frederick, et al. (författare)
  • Age dependency in the timing of mitral annular motion in relation to ventricular filling in healthy subjects : Umea General Population Heart Study
  • 2008
  • Ingår i: European Journal of Echocardiography. - : Oxford University Press (OUP). - 1525-2167 .- 1532-2114. ; 9:4, s. 522-529
  • Tidskriftsartikel (refereegranskat)abstract
    • AIMS: Peak left ventricular (LV) relaxation normally precedes peak filling (E), which supports the hypothesis that LV suction contributes to early-diastolic filling. The significance of similar temporal discordance in late diastole has previously not been studied. We describe the time relationships between mitral annular motion and LV filling in early and late diastole and examine the effect of normal ageing on these time intervals. METHODS AND RESULTS: A total of 128 healthy subjects aged 25-88 years were studied. Transmitral and pulmonary venous flow reversals (Ar) were recorded by Doppler echocardiography. Mitral annular diastolic displacement-early (E(m)) and late (A(m))-were recorded by Doppler tissue imaging. With reference to electrocardiographic R and P-waves, the following measurements were made: R to peak E-wave (R-E) and E(m) (R-E(m)); onset P to peak A-wave (P-pA), A(m) (P-pA(m)), and Ar (P-pAr). The differences between [(R-E) and (R-E(m))] for early-diastolic temporal discordance (EDTD) and [(P-A) and (P-A(m))] for late-diastolic temporal discordance (LDTD) were calculated. Isovolumic relaxation time (IVRT) was also measured. Early-diastolic temporal discordance was approximately 26 ms in all age groups. Late-diastolic temporal discordance, however, was inversely related to age (r = -0.35, P < 0.001) and IVRT (r = -0.34, P < 0.001) and therefore decreased in the elderly vs. young (13 +/- 10 vs. 23 +/- 10 ms; P < 0.001). In multivariate analysis, age failed to predict LDTD in the presence of IVRT. A, A(m), and Ar were simultaneous at onset, and peak A(m) coincided with peak Ar in all age groups (r = 0.97, P < 0.001). No significant differences were noted in the RR intervals. CONCLUSIONS: Sequential prolongation of IVRT with ageing reduces LDTD, thus converging the peaks of A(m), A, and Ar (atrial mechanical alignment)-a potential novel method to identify subjects at increased dependency on atrial contraction for late-diastolic filling.
  •  
10.
  • Bukachi, Frederich, et al. (författare)
  • Pulmonary venous flow reversal and its relationship to atrial mechanical function in normal subjects--Umeå General Population Heart Study.
  • 2005
  • Ingår i: European Journal of Echocardiography. - : Oxford University Press (OUP). - 1525-2167 .- 1532-2114. ; 6:2, s. 107-116
  • Tidskriftsartikel (refereegranskat)abstract
    • AIMS: Although pulmonary venous flow reversal (Ar) is useful in the evaluation of left ventricular (LV) diastolic function, it is often difficult to study with transthoracic echocardiography (TTE). We determined the relationship between Ar and left atrial (LA) mechanical function and sought to define surrogate measurements for Ar. METHODS AND RESULTS: A total of 130 healthy subjects, mean age 54.3+/-18.3 years, 62 women, were studied and classified into three groups: [young (Y), 25-44 years; n=44], [middle-age (M), 45-64 years; n=43] and [elderly (E), > or =65 years; n=43]. Pulmonary venous flow and LV inflow studies were performed by TTE and LV basal free-wall motion was studied by Doppler tissue imaging (DTI). All images were acquired with a superimposed electrocardiogram. RR interval was similar in all groups while LA dimension and PR interval were increased in Group E vs. Y (P<0.001). LA contraction (A(m)) on DTI, transmitral A-wave (A) and Ar were simultaneous and started 84ms after onset of P wave and this interval increased with age (P=0.02). Similarly, the time intervals from the same landmark to peak A(m), A, and Ar were prolonged with age (all, P<0.001). Despite this prolongation, peak A(m) coincided with peak Ar in every age group (r=0.97, P<0.001) and Ar acceleration and deceleration times were consistently equal. CONCLUSION: The timing of A(m) obtained by DTI can be used to accurately estimate corresponding measurements of Ar recorded by TTE in subjects without cardiac disease.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 58
Typ av publikation
tidskriftsartikel (57)
konferensbidrag (1)
Typ av innehåll
refereegranskat (55)
övrigt vetenskapligt/konstnärligt (3)
Författare/redaktör
Lindqvist, Per (10)
Bjällmark, Anna (10)
Brodin, Lars-Åke (9)
Larsson, M (7)
Waldenström, Anders (5)
Kazzam, Elsadig (5)
visa fler...
Flachskampf, Frank, ... (5)
Henein, Michael (5)
Winter, Reidar (5)
Lind, B (4)
Lind, Britta (4)
Nowak, Jacek (4)
Sicari, Rosa (4)
Henein, Michael Y. (3)
Nowak, J. (3)
Flachskampf, Frank A ... (3)
Bech-Hanssen, Odd, 1 ... (3)
Mörner, Stellan (3)
Nihoyannopoulos, Pet ... (3)
Winter, R. (3)
Hatle, L. (3)
Evangelista, Arturo (3)
Zamorano, Jose (3)
Mårtensson, Mattias (3)
Waldenstrom, A. (2)
Gustafsson, U (2)
Wikström, Gerhard (2)
Caidahl, Kenneth, 19 ... (2)
Bajraktari, Gani (2)
Alam, M (2)
Samad, BA (2)
Nordlander, R (2)
Guron, Cecilia Walle ... (2)
Brodin, LA (2)
Wikh, R (2)
Brodin, L (2)
Willenheimer, Ronnie (2)
Nygren, M. (2)
Olsson, Mats (2)
Edner, M (2)
Lindqvist, P. (2)
Shahgaldi, Kambiz (2)
Brodin, Lars-Ake (2)
Quintana, M. (2)
Saha, Samir (2)
Ring, M (2)
Fox, Kevin (2)
Klinghammer, Lutz (2)
Daniel, Werner G. (2)
Fraser, Alan (2)
visa färre...
Lärosäte
Karolinska Institutet (16)
Umeå universitet (13)
Kungliga Tekniska Högskolan (13)
Uppsala universitet (11)
Jönköping University (10)
Göteborgs universitet (5)
visa fler...
Linköpings universitet (5)
Lunds universitet (3)
visa färre...
Språk
Engelska (58)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (21)
Teknik (11)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy