SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Dance A) "

Sökning: WFRF:(Dance A)

  • Resultat 1-9 av 9
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Kanai, M, et al. (författare)
  • 2023
  • swepub:Mat__t
  •  
2.
  • Niemi, MEK, et al. (författare)
  • 2021
  • swepub:Mat__t
  •  
3.
  • Dance, Sarah L., et al. (författare)
  • Improvements in Forecasting Intense Rainfall : Results from the FRANC (Forecasting Rainfall Exploiting New Data Assimilation Techniques and Novel Observations of Convection) Project
  • 2019
  • Ingår i: Atmosphere. - : MDPI. - 2073-4433. ; 10:3
  • Forskningsöversikt (refereegranskat)abstract
    • The FRANC project (Forecasting Rainfall exploiting new data Assimilation techniques and Novel observations of Convection) has researched improvements in numerical weather prediction of convective rainfall via the reduction of initial condition uncertainty. This article provides an overview of the project's achievements. We highlight new radar techniques: correcting for attenuation of the radar return; correction for beams that are over 90% blocked by trees or towers close to the radar; and direct assimilation of radar reflectivity and refractivity. We discuss the treatment of uncertainty in data assimilation: new methods for estimation of observation uncertainties with novel applications to Doppler radar winds, Atmospheric Motion Vectors, and satellite radiances; a new algorithm for implementation of spatially-correlated observation error statistics in operational data assimilation; and innovative treatment of moist processes in the background error covariance model. We present results indicating a link between the spatial predictability of convection and convective regimes, with potential to allow improved forecast interpretation. The research was carried out as a partnership between University researchers and the Met Office (UK). We discuss the benefits of this approach and the impact of our research, which has helped to improve operational forecasts for convective rainfall events.
  •  
4.
  • Dance, D, et al. (författare)
  • Breast dosimetry using high-resolution voxel phantoms
  • 2005
  • Ingår i: Radiation Protection Dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 114:1-3, s. 359-363
  • Tidskriftsartikel (refereegranskat)abstract
    • A computer model of X-ray mammography has been developed, which uses quasi-realistic high-resolution voxel phantoms to simulate the breast. The phantoms have 400 μm voxels and simulate the three-dimensional distributions of adipose and fibroglandular tissues, Cooper's ligaments, ducts and skin and allow the estimation of dose to individual tissues. Calculations of the incident air kerma to mean glandular dose conversion factor, g, were made using a Mo/Mo spectrum at 28 kV for eight phantoms in the thickness range 40-80 mm and of varying glandularity. The values differed from standard tabulations used for breast dosimetry by up to 43%, because of the different spatial distribution of glandular tissue within the breast. To study this further, additional voxel phantoms were constructed, which gave variations of between 9 and 59% compared with standard values. For accurate breast dosimetry, it is therefore very important to take the distribution of glandular tissues into account. © The Author 2005. Published by Oxford University Press. All rights reserved.
  •  
5.
  •  
6.
  • Hunt, R, et al. (författare)
  • Calculation of the properties of digital mammograms using a computer simulation
  • 2005
  • Ingår i: Radiation Protection Dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 114:1-3, s. 395-398
  • Tidskriftsartikel (refereegranskat)abstract
    • A Mote Carlo computer model of mammography has been developed to study and optimise the performance of digital mammographic systems. The program uses high-resolution voxel phantoms to model the breast, which simulate the adipose and fibroglandular tissues, Cooper's ligaments, ducts and skin in three dimensions. The model calculates the dose to each tissue, and also the quantities such as energy imparted to image pixels, noise per image pixel and scatter-to-primary (S/P) ratios. It allows studies of the dependence of image properties on breast structure and on position within the image. The program has been calibrated by calculating and measuring the pixel values and noise for a digital mammographic system. The thicknesses of two components of this system were unknown, and were adjusted to obtain a good agreement between measurement and calculation. The utility of the program is demonstrated with the calculations of the variation of the S/P ratio with and without a grid, and of the image contrast across the image of a 50-mm-thick breast phantom. © The Author 2005. Published by Oxford University Press. All rights reserved.
  •  
7.
  • Sandborg, Michael, 1961-, et al. (författare)
  • Demonstration of correlations between clinical and physical image quality measures in chest and lumbar spine screen-film radiography
  • 2001
  • Ingår i: British Journal of Radiology. - : British Institute of Radiology. - 0007-1285 .- 1748-880X. ; 74:882, s. 520-528
  • Tidskriftsartikel (refereegranskat)abstract
    • The ability to predict clinical image quality from physical measures is useful for optimization in diagnostic radiology. In this work, clinical and physical assessments of image quality are compared and correlations between the two are derived. Clinical assessment has been made by a group of expert radiologists who evaluated fulfilment of the European image criteria for chest and lumbar spine radiography using two scoring methods: image criteria score (ICS) and visual grading analysis score (VGAS). Physical image quality measures were calculated using a Monte Carlo simulation model of the complete imaging system. This model includes a voxelized male anatomy and was used to calculate contrast and signal-to-noise ratio of various important anatomical details and measures of dynamic range. Correlations between the physical image quality measures on the one hand and the ICS and VGAS on the other were sought. 16 chest and 4 lumbar spine imaging system configurations were compared in frontal projection. A statistically significant correlation with clinical image quality was found in chest posteroanterior radiography for the contrast of blood vessels in the retrocardiac area and a measure of useful dynamic range. In lumbar spine anteroposterior radiography, a similar significant correlation with clinical image quality was found between the contrast and signal-to-noise ratio of the trabecular structures in the L1-L5 vertebrae. The significant correlation shows that clinical image quality can, at least in some cases, be predicted from appropriate measures of physical image quality.
  •  
8.
  • Tingberg, Anders, et al. (författare)
  • Influence of the characteristic curve on the clinical image quality of lumbar spine and chest radiographs.
  • 2004
  • Ingår i: The British journal of radiology. - : British Institute of Radiology. - 0007-1285 .- 1748-880X. ; 77:915, s. 204-15
  • Tidskriftsartikel (refereegranskat)abstract
    • The "European Guidelines on Quality Criteria for Diagnostic Radiographic Images" do not address the choice of the film characteristic (H&D) curve, which is an important parameter for the description of a radiographic screen-film system. The image contrast of clinical lumbar spine and chest radiographs was altered by digital image processing techniques, simulating images with different H&D curves, both steeper and flatter than the original. The manipulated images were printed on film for evaluation. Seven experienced radiologists evaluated the clinical image quality by analysing the fulfilment of the European Image Criteria (ICS) and by visual grading analysis (VGA) of in total 224 lumbar spine and 360 chest images. A parallel study of the effect of the H&D curve has also been made using a theoretical model. The contrast (DeltaOD) of relevant anatomical details was calculated, using a Monte Carlo simulation-model of the complete imaging system including a 3D voxel phantom of a patient. Correlations between the calculated contrast and the radiologists' assessment by VGA were sought. The results of the radiologists' assessment show that the quality in selected regions of lumbar spine and chest images can be significantly improved by the use of films with a steeper H&D curve compared with the standard latitude film. Significant (p<0.05) correlations were found between the VGA results and the calculations of the contrast of transverse processes and trabecular details in the lumbar spine vertebrae, and with the contrast of blood vessels in the retrocardiac area of the chest.
  •  
9.
  • Ullman, Gustaf, et al. (författare)
  • Towards optimization in digital chest radiography using Monte Carlo modelling
  • 2006
  • Ingår i: Physics in medicine and biology. - : IOP Publishing. - 0031-9155 .- 1361-6560. ; 51:11, s. 2729-2743
  • Tidskriftsartikel (refereegranskat)abstract
    • A Monte Carlo based computer model of the x-ray imaging system was used to investigate how various image quality parameters of interest in chest PA radiography and the effective dose E vary with tube voltage (90–150 kV), additional copper filtration (0–0.5 mm), anti-scatter method (grid ratios 8–16 and air gap lengths 20–40 cm) and patient thickness (20–28 cm) in a computed radiography (CR) system. Calculated quantities were normalized to a fixed value of air kerma (5.0 µGy) at the automatic exposure control chambers. Soft-tissue nodules were positioned at different locations in the anatomy and calcifications in the apical region. The signal-to-noise ratio, SNR, of the nodules and the nodule contrast relative to the contrast of bone (C/CB) as well as relative to the dynamic range in the image (Crel) were used as image quality measures. In all anatomical regions, except in the densest regions in the thickest patients, the air gap technique provides higher SNR and contrast ratios than the grid technique and at a lower effective dose E. Choice of tube voltage depends on whether quantum noise (SNR) or the contrast ratios are most relevant for the diagnostic task. SNR increases with decreasing tube voltage while C/CB increases with increasing tube voltage.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-9 av 9

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy