SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Gottrup F.) "

Sökning: WFRF:(Gottrup F.)

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Dehlin, Ove, et al. (författare)
  • Monochromatic phototherapy in elderly patients: A new way of treating chronic pressure ulcers?
  • 2003
  • Ingår i: Aging clinical and experimental research. - 1720-8319. ; 15:3, s. 259-263
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and aims: Monochromatic pulsating light may have effects of importance for wound healing, and promising results were obtained in an open study on the healing of pressure ulcers, which motivated the present study. Methods: One hundred and sixty-four in- and outpatients with grade II and III ulcers were treated with monochromatic pulsating light or placebo over the ulcerated area, according to a specific therapeutic program. Results: No significant effects were observed in the total material. In a sub-analysis of grade II ulcers, there was a tendency toward better healing in the monochromatic light group (p=0.06). A significantly larger reduction in pressure ulcer size was noted among patients in the treatment group with low body weight (BMI<20). Conclusions: Monochromatic pulsating light may have effects on pressure ulcer healing, and a new study focusing only on grade II ulcers is under way. (C)2003, Editrice Kurtis
  •  
2.
  •  
3.
  •  
4.
  • Johnson, Louis Banka, et al. (författare)
  • Combination of pre-operative radiotherapy and surgery suppresses local accumulation of collagen and TGF-beta 1 in rats
  • 2006
  • Ingår i: Journal of Surgical Research. - : Elsevier BV. - 1095-8673 .- 0022-4804. ; 133:2, s. 136-142
  • Tidskriftsartikel (refereegranskat)abstract
    • Background. The systemic and local tissue repair responses of radiation in combination with surgery are still unclear. We have studied the effect of fractionated pre-operative radiotherapy with or without subsequent laparotomy on collagen accumulation using a rodent model. Materials and methods. Thirty-two male Sprague-Dawley rats were divided into four groups (eight rats per group): 1) sham radiation and sham laparotomy (control); 2) sham radiation and laparotomy; 3) radiation and sham laparotomy; and 4) radiation followed by laparotomy. Expanded polytetrafluoroethylene (ePTFE) tubes were implanted subcutaneously in the abdominal wall in the radiotherapy field and on the back outside the radiotherapy field day 0. The abdomen (3 cm x 4 cm) was irradiated day 3 (10 Gy) and again day 7 (10 Gy). On day 10, implants were extirpated, laparotomy undertaken in groups 2 and 4 and new ePTFE tubes implanted subcutaneously. The second implants were extirpated on day 20. Implants were analyzed for hydroxyproline, total protein and transforming growth factor-ss 1 (TGF-ss 1) levels. Results. On day 10, hydroxyproline (P < 0.05) and TGF-ss 1 (P < 0.001) were lower in ePTFE tubes in irra-diated compared with non-irradiated rats. On day 20, the abdominal ePTFE hydroxyproline remained low (P < 0.001) in animals subjected to laparotomy and pre-operative irradiation while hydroxyproline levels of rats subjected to irradiation only were similar to controls. The effects of radiation on hydroxyproline were confined to the irradiated abdominal area. There was a positive correlation between hydroxyproline and TGF-ss 1 levels in the abdominal wall implant day 20 (r = 0.53, P < 0.005). Conclusion. A clinically relevant fractionated radiation scheme reduced subcutaneous collagen accumulation pre-operatively and profoundly within the radiation field post-operatively after laparotomy, possibly because of lowered TGF ss 1 levels. (c) 2006 Elsevier Inc. All rights reserved.
  •  
5.
  • Norkus, A, et al. (författare)
  • Use of a hydrocapillary dressing in the management of highly exuding ulcers; a comparative study
  • 2005
  • Ingår i: Journal of Wound Care. - 0969-0700. ; 14:9, s. 129-432
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: To evaluate the safety and performance of Alione Hydrocapillary dressing (Coloplast A/S) in the management of highly exuding chronic venous leg ulcers and compare it with two hydropolymer dressings, Tielle and Tielle Plus (Johnson & Johnson). Method: A comparative clinical trial was conducted on 97 patients with an ankle brachial pressure index ?0.8 and a highly exuding leg ulcer. Ulcer duration was at least four weeks. Treatment continued until healing or for a maximum of 12 months. Results: There was no statistically significant difference in healing time or wound area reduction between the two treatment protocols. The test dressing (Alione Hydrocapillary) had better absorption capacity and was more comfortable for the patients than the comparator dressings (Tielle/Tielle Plus) and adhered less to the wound bed. Also, more patients preferred the test dressing to their previous treatment. Although severe leakage and maceration were observed more frequently in the comparator group compared with the test group, this was not statistically significant. Conclusion: Both treatment protocols were safe and effective in treating highly exuding chronic venous leg ulcers. The test dressing performed as well as or better than the comparator dressings for all study parameters and more patients preferred the test dressing to their previous dressing compared with the comparator dressings.
  •  
6.
  • Palosuo, T, et al. (författare)
  • Latex medical gloves: time for a reappraisal
  • 2011
  • Ingår i: International archives of allergy and immunology. - : S. Karger AG. - 1423-0097 .- 1018-2438. ; 156:3, s. 234-246
  • Tidskriftsartikel (refereegranskat)abstract
    • Many hospitals have implemented policies to restrict or ban the use of devices made of natural rubber latex (NRL) in healthcare as precautionary measures against the perceived risk of NRL allergy. Changes in glove technology, progress in measuring the specific allergenic potential of gloves and a dramatic decrease in the prevalence of NRL allergies after interventions and education prompted us to revisit the basis for justifiable glove selection policies. The published Anglophone literature from 1990 to 2010 was reviewed for original articles and reviews dealing with the barrier and performance properties of NRL and synthetic gloves and the role of glove powder. The review shows that NRL medical gloves, when compared with synthetic gloves, tend to be stronger, more flexible and better accepted by clinicians. The introduction of powder-free gloves has been associated with reductions in protein content and associated allergies. Recently, new methods to quantify clinically relevant NRL allergens have enabled the identification of gloves with low allergenic potential. The use of low-protein, low-allergenic, powder-free gloves is associated with a significant decrease in the prevalence of type I allergic reactions to NRL among healthcare workers. Given the excellent barrier properties and operating characteristics, dramatically reduced incidences of allergic reactions, availability of specific tests for selection of low-allergen gloves, competitive costs and low environmental impact, the use of NRL gloves within the hospital environment warrants reappraisal.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy