1.
  •  
2.
  • Sejersten, Maria, et al. (författare)
  • Detection of acute ischemia from the EASI-derived 12-lead electrocardiogram and from the 12-lead electrocardiogram acquired in clinical practice
  • 2007
  • Ingår i: Journal of Electrocardiology. - : Elsevier BV. - 1532-8430 .- 0022-0736. ; 40:2, s. 120-126
  • Tidskriftsartikel (refereegranskat)abstract
    • ST-segment measurements in the standard 12-lead electrocardiogram (ECG) of patients with acute coronary syndromes are crucial for these patients' management. Our objective was to determine whether the 12-lead ECG derived from the 3-lead EASI system can attain a level of diagnostic performance similar to that of the Mason-Likar (ML) 12-lead ECG acquired in clinical practice (CP) by paramedics and emergency department technicians. Using 120-lead body surface potential maps recorded before and during balloon inflation angioplasty from 88 patients (divided into "responders" and "nonresponders"), and electrode placement data from 60 applications of precordial leads in CP, we generated for the "nonischemic" and "ischemic' states of each patient the following lead sets: the ML 12-lead ECG, the EASI-derived 12-lead ECG, and 60 sets of 12-lead CP ECGs. We extracted ST deviations at J + 60 milliseconds, summed them for all 12 leads of each lead set to obtain Sigma ST, and, by using the bootstrap method, determined the mean sensitivity and specificity for recognizing the "ischemic' state at various thresholds of Sigma ST. Results were displayed as receiver operating characteristics, and the area under these curves (AUC) +/- SE was used as the measure of diagnostic performance. AUC SE for all patients were ML ECG, 0.66 +/- 0.03; EASI ECG, 0.64 +/- 0.03; and CP ECG, 0.67 +/- 0.03. Corresponding results for responders only were 0.81 +/- 0.04 for ML ECG, 0.78 +/- 0.04 for EASI ECG, and 0.81 +/- 0.04 for CP ECG. The differences between the AUCs for the different lead sets were not significant (P >.05). Thus, the EASI-derived 12-lead ECG is as good for detecting acute ischemia as is the 12-lead ECG acquired in CP. (c) 2007 Elsevier Inc. All rights reserved.
  •  
3.
  • ter Haar, C. Cato, et al. (författare)
  • Difference vectors to describe dynamics of the ST segment and the ventricular gradient in acute ischemia
  • 2013
  • Ingår i: Journal of Electrocardiology. - : Elsevier BV. - 1532-8430 .- 0022-0736. ; 46:4, s. 302-311
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: The ECG is important in the diagnosis and triage of the acute coronary syndrome (ACS), especially in the hyperacute phase, the "golden hours," during which myocardial salvage possibilities are largest. An important triaging decision to be taken is whether or not a patient requires primary PCI, for which, as mentioned in the guidelines, the presence of an ST elevation (STE) pattern in the ECG is a major criterion. However, preexisting non-zero ST amplitudes (diagnostic, but also non-diagnostic) can obscure or even preclude this diagnosis. Methods: In this study, we investigated the potential diagnostic possibilities of ischemia detection by means of changes in the ST vector, Delta ST, and changes in the VG (QRST integral) vector, Delta VG. We studied the vectorcardiograms (VCGs) synthesized of the ECGs of 84 patients who underwent elective PTCA. Mean +/- SD balloon occlusion times were 260 +/- 76 s. The ECG ischemia diagnosis (ST elevation, STE, or non-ST-elevation, NSTE), magnitudes and orientations of the ST and VG vectors, and the differences Delta ST and Delta VG with the baseline ECG were measured after 3 min of balloon occlusion. Results: Planar angles between the Delta ST and Delta VG vectors were 14.9 +/- 14.0 degrees. Linear regression of Delta VG on Delta ST yielded Delta VG = 324. Delta ST (r = 0.85; P < 0.0001, Delta ST in mV). We adopted Delta ST > 0.05 mV, and the corresponding Delta VG > 16.2 mV.ms as ischemia thresholds. The classical criteria characterized the ECGs of 46/84 (55%) patients after 3 min of occlusion as STE ECGs. Combined application of the Delta ST and Delta VG criteria identified 73/84 (87%) of the patients as ischemic. Conclusion: Differential diagnosis by Delta ST and Delta VG (requiring an earlier made non-ischemic baseline ECG) could dramatically improve ECG guided detection of patients who urgently require catheter intervention. (C) 2013 Elsevier Inc. All rights reserved.
  •  
4.
  • Wang, John J., et al. (författare)
  • Criteria for ECG detection of acute myocardial ischemia : Sensitivity versus specificity
  • 2018
  • Ingår i: Journal of Electrocardiology. - : Elsevier BV. - 0022-0736. ; 51:6, s. 12-17
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Criteria for electrocardiographic detection of acute myocardial ischemia recommended by the Consensus Document of ESC/ACCF/AHA/WHF consist of two parts: The ST elevation myocardial infarction (STEMI) criteria based on ST elevation (ST↑) in 10 pairs of contiguous leads and the other on ST depression (ST↓) in the same 10 contiguous pairs. Our aim was to assess sensitivity (SE) and specificity (SP) of these criteria—and to seek their possible improvements—in three databases of 12‑lead ECGs. Methods: We used (1) STAFF III data of controlled ischemic episodes recorded from 99 patients (pts) during percutaneous coronary intervention (PCI) involving either left anterior descending (LAD) coronary artery, right coronary artery (RCA), or left circumflex (LCx) coronary artery. (2) Data from the University of Glasgow for 58 pts with acute myocardial infarction (AMI) and 58 pts without AMI, as confirmed by MRI. (3) Data from Lund University retrieved from a centralized ECG management system for 100 pts with various pathological ST changes—other than acute coronary occlusion—including ventricular pre-excitation, acute pericarditis, early repolarization syndrome, left ventricular hypertrophy, and left bundle branch block. ST measurements at J-point in ECGs of all 315 pts were obtained automatically on the averaged beat with manual review and the recommended criteria as well as their proposed modifications, were applied. Performance measures included SE, SP, positive predictive value (PPV), and benefit-to-harm ratio (BHR), defined as the ratio of true-positive vs. false-positive detections. Results: We found that the SE of widely-used STEMI criteria can be indeed improved by the additional ST↓ criteria, but at the cost of markedly decreased SP. In contrast, using ST↑ in only 3 additional contiguous pairs of leads (STEMI13) can boost SE without any loss of SP. In the STAFF III database, SE/SP/PPV were 56/98/97% for the STEMI, 79/79/79% for the STEMI with added ST↓ and 67/97/96% for the STEMI13. In the Glasgow database, corresponding SE/SP/PPV were 43/98/96%, 84/90/89%, and 55/98/97%. For the Lund database, SP was 56% for the STEMI, 24% for the STEMI with ST↓, and 56% for the STEMI13. Conclusion: Current recommended criteria for detecting acute myocardial ischemia, involving ST↓, boost SE of widely-used STEMI criteria, at the cost of SP. To keep the SP high, we propose either the adjustment of threshold for the added ST↓ criteria or a selective use of ST↓ only in contiguous leads V2 and V3 plus ST↑ in lead pairs (aVL, –III) and (III, –aVL).
  •  
5.
  • Welinder, Annika, et al. (författare)
  • EASI-Derived vs standard 12-lead electrocardiogram for Selvester QRS score estimations of chronic myocardial infarct size, using cardiac magnetic resonance imaging as gold standard.
  • 2009
  • Ingår i: Journal of Electrocardiology. - : Elsevier BV. - 1532-8430 .- 0022-0736. ; 42, s. 145-151
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: The size of myocardial infarction (MI) is of significance for the prognosis. Selvester scores might be valuable for this estimation. OBJECTIVE: To compare the differences in Selvester scores for chronic MI provided from standard and EASI-derived 12-lead electrocardiograms (ECGs) and to compare these scores to the MI size measured by delayed-enhancement magnetic resonance imaging (DE-MRI). METHODS: Thirty-seven patients were studied. In connection with their DE-MRI scan follow-up after chest pain, body surface potential mapping was performed. Standard and EASI 12-lead ECGs were constructed from the maps. Two investigators manually performed the measurements required for scoring with the Selvester system using quad-plot format of the ECGs. One of the investigators repeated this once for the standard leads. RESULTS: Neither the association nor the agreement between MRI and EASI leads or between MRI and standard leads was very strong. CONCLUSIONS: The Selvester QRS scoring system needs further improvement.
  •  