SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Janal M. N.) "

Sökning: WFRF:(Janal M. N.)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Jimbo, Ryo, et al. (författare)
  • Nano Hydroxyapatite-coated Implants Improve Bone Nanomechanical Properties
  • 2012
  • Ingår i: Journal of Dental Research. - : SAGE Publications. - 0022-0345 .- 1544-0591. ; 91:12, s. 1172-1177
  • Tidskriftsartikel (refereegranskat)abstract
    • Nanostructure modification of dental implants has long been sought as a means to improve osseointegration through enhanced biomimicry of host structures. Several methods have been proposed and demonstrated for creating nanotopographic features; here we describe a nanoscale hydroxyapatite (HA)-coated implant surface and hypothesize that it will hasten osseointegration and improve its quality relative to that of non-coated implants. Twenty threaded titanium alloy implants, half prepared with a stable HA nanoparticle surface and half grit-blasted, acid-etched, and heat-treated (HT), were inserted into rabbit femurs. Pre-operatively, the implants were morphologically and topographically characterized. After 3 weeks of healing, the samples were retrieved for histomorphometry. The nanomechanical properties of the surrounding bone were evaluated by nanoindentation. While both implants revealed similar bone-to-implant contact, the nanoindentation demonstrated that the tissue quality was significantly enhanced around the HA-coated implants, validating the postulated hypothesis.
  •  
2.
  • Jimbo, Ryo, et al. (författare)
  • The impact of a modified cutting flute implant design on osseointegration
  • 2014
  • Ingår i: International Journal of Oral and Maxillofacial Surgery. - : Elsevier. - 0901-5027 .- 1399-0020. ; 43:7, s. 883-888
  • Tidskriftsartikel (refereegranskat)abstract
    • Information concerning the effects of the implant cutting flute design on initial stability and its influence on osseointegration in vivo is limited. This study evaluated the early effects of implants with a specific cutting flute design placed in the sheep mandible. Forty-eight dental implants with two different macrogeometries (24 with a specific cutting flute design Blossom group; 24 with a self-tapping design - DT group) were inserted into the mandibular bodies of six sheep; the maximum insertion torque was recorded. Samples were retrieved and processed for histomorphometric analysis after 3 and 6 weeks. The mean insertion torque was lower for Blossom implants (P < 0.001). No differences in histomorphometric results were observed between the groups. At 3 weeks, P = 0.58 for bone-to-implant contact (BIC) and P = 0.52 for bone area fraction occupied (BAFO); at 6 weeks, P = 0.55 for BIC and P = 0.45 for BAFO. While no histomorphometric differences were observed, ground sections showed different healing patterns between the implants, with better peri-implant bone organization around those with the specific cutting flute design (Blossom group). Implants with the modified cutting flute design had a significantly reduced insertion torque compared to the DT implants with a traditional cutting thread, and resulted in a different healing pattern.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy