SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Madorno Matias) "

Sökning: WFRF:(Madorno Matias)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Gogniat, Emiliano, et al. (författare)
  • Dead space analysis at different levels of positive end-expiratory pressure in acute respiratory distress syndrome patients
  • 2018
  • Ingår i: Journal of critical care. - : W B SAUNDERS CO-ELSEVIER INC. - 0883-9441 .- 1557-8615. ; 45, s. 231-238
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To analyze the effects of positive end-expiratory pressure (PEEP) on Bohr's dead space (VDBohr/VT) in patients with acute respiratory distress syndrome (ARDS).Material and methods: Fourteen ARDS patients under lung protective ventilation settingswere submitted to 4 different levels of PEEP (0, 6, 10, 16 cmH(2)O). Respiratory mechanics, hemodynamics and volumetric capnography were recorded at each protocol step.Results: Two groups of patients responded differently to PEEP when comparing baseline with 16-PEEP: those in which driving pressure increased > 15% (Delta P.(15%), n = 7, p = .016) and those in which the change was <= 15% (Delta P-<= 15%, n = 7, p = .700). VDBohr/VT was higher in Delta P-<= 15% than in Delta P-<= 15% patients at baseline ventilation [0.58 (0.49-0.60) vs 0.46 (0.43-0.46) p = .018], at 0-PEEP [0.50 (0.47-0.54) vs 0.41 (0.40-0.43) p = .012], at 6-PEEP [0.55 (0.49-0.57) vs 0.44 (0.42-0.45) p = .008], at 10-PEEP [0.59 (0.51-0.59) vs 0.45 (0.44-0.46) p = .006] and at 16-PEEP [0.61 (0.56-0.65) vs 0.47 (0.45-0.48) p =. 001]. We found a good correlation between Delta P and VDBohr/VT only in the Delta P.(15%) group (r = 0.74, p < .001).Conclusions: Increases in PEEP result in higher VDBohr/VT only when associated with an increase in driving pressure.
  •  
2.
  • Tusman, Gerardo, et al. (författare)
  • Multimodal non-invasive monitoring to apply an open lung approach strategy in morbidly obese patients during bariatric surgery
  • 2020
  • Ingår i: Journal of clinical monitoring and computing. - : SPRINGER HEIDELBERG. - 1387-1307 .- 1573-2614. ; 34:5, s. 1015-1024
  • Tidskriftsartikel (refereegranskat)abstract
    • To evaluate the use of non-invasive variables for monitoring an open-lung approach (OLA) strategy in bariatric surgery. Twelve morbidly obese patients undergoing bariatric surgery received a baseline protective ventilation with 8 cmH(2)O of positive-end expiratory pressure (PEEP). Then, the OLA strategy was applied consisting in lung recruitment followed by a decremental PEEP trial, from 20 to 8 cmH(2)O, in steps of 2 cmH(2)O to find the lung's closing pressure. Baseline ventilation was then resumed setting open lung PEEP (OL-PEEP) at 2 cmH(2)O above this pressure. The multimodal non-invasive variables used for monitoring OLA consisted in pulse oximetry (SpO(2)), respiratory compliance (Crs), end-expiratory lung volume measured by a capnodynamic method (EELVCO2), and esophageal manometry. OL-PEEP was detected at 15.9 +/- 1.7 cmH(2)O corresponding to a positive end-expiratory transpulmonary pressure (P-L,P-ee) of 0.9 +/- 1.1 cmH(2)O. ROC analysis showed that SpO(2) was more accurate (AUC 0.92, IC95% 0.87-0.97) than Crs (AUC 0.76, IC95% 0.87-0.97) and EELVCO2 (AUC 0.73, IC95% 0.64-0.82) to detect the lung's closing pressure according to the change of P-L,P-ee from positive to negative values. Compared to baseline ventilation with 8 cmH(2)O of PEEP, OLA increased EELVCO2 (1309 +/- 517 vs. 2177 +/- 679 mL) and decreased driving pressure (18.3 +/- 2.2 vs. 10.1 +/- 1.7 cmH(2)O), estimated shunt (17.7 +/- 3.4 vs. 4.2 +/- 1.4%), lung strain (0.39 +/- 0.07 vs. 0.22 +/- 0.06) and lung elastance (28.4 +/- 5.8 vs. 15.3 +/- 4.3 cmH(2)O/L), respectively; all p < 0.0001. The OLA strategy can be monitored using noninvasive variables during bariatric surgery. This strategy decreased lung strain, elastance and driving pressure compared with standard protective ventilatory settings. Clinical trial number NTC03694665.
  •  
3.
  • Tusman, Gerardo, et al. (författare)
  • Photoplethysmographic characterization of vascular tone mediated changes in arterial pressure : an observational study
  • 2019
  • Ingår i: Journal of clinical monitoring and computing. - : SPRINGER HEIDELBERG. - 1387-1307 .- 1573-2614. ; 33:5, s. 815-824
  • Tidskriftsartikel (refereegranskat)abstract
    • To determine whether a classification based on the contour of the photoplethysmography signal (PPGc) can detect changes in systolic arterial blood pressure (SAP) and vascular tone. Episodes of normotension (SAP 90-140 mmHg), hypertension (SAP > 140 mmHg) and hypotension (SAP < 90 mmHg) were analyzed in 15 cardiac surgery patients. SAP and two surrogates of the vascular tone, systemic vascular resistance (SVR) and vascular compliance (Cvasc = stroke volume/pulse pressure) were compared with PPGc. Changes in PPG amplitude (foot-to-peak distance) and dicrotic notch position were used to define 6 classes taking class III as a normal vascular tone with a notch placed between 20 and 50% of the PPG amplitude. Class I-to-II represented vasoconstriction with notch placed > 50% in a small PPG, while class IV-to-VI described vasodilation with a notch placed < 20% in a tall PPG wave. 190 datasets were analyzed including 61 episodes of hypertension [SAP = 159 (151-170) mmHg (median 1st-3rd quartiles)], 84 of normotension, SAP = 124 (113-131) mmHg and 45 of hypotension SAP = 85(80-87) mmHg. SAP were well correlated with SVR (r = 0.78, p < 0.0001) and Cvasc (r = 0.84, p < 0.0001). The PPG-based classification correlated well with SAP (r = - 0.90, p < 0.0001), SVR (r = - 0.72, p < 0.0001) and Cvasc (r = 0.82, p < 0.0001). The PPGc misclassified 7 out of the 190 episodes, presenting good accuracy (98.4% and 97.8%), sensitivity (100% and 94.9%) and specificity (97.9% and 99.2%) for detecting episodes of hypotension and hypertension, respectively. Changes in arterial pressure and vascular tone were closely related to the proposed classification based on PPG waveform. Clinical Trial Registration NTC02854852.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy