1.
  • Gustafsson, Johan, et al. (author)
  • Feasibility and limitations of quantitative SPECT for 223Ra
  • 2020
  • In: Physics in Medicine and Biology. - : IOP Publishing. - 0031-9155 .- 1361-6560. ; 65:8
  • Journal article (peer-reviewed)abstract
    • The aim of this paper is to investigate the feasibility and limitations of activity-concentration estimation for 223Ra using SPECT. Phantom measurements are performed using spheres (volumes 5.5 mL to 26.4 mL, concentrations 1.6 kBq mL-1 to 4.5 kBq mL-1). Furthermore, SPECT projections are simulated using the SIMIND Monte Carlo program for two geometries, one similar to the physical phantom and the other being an anthropomorphic phantom with added lesions (volumes 34 mL to 100 mL, concentrations 0.5 kBq mL-1 to 4 kBq mL-1). Medium-energy and high-energy collimators, 60 projections with 55 s per projection and a 20% energy window at 82 keV are employed. For the Monte Carlo simulated images, Poisson-distributed noise is added in ten noise realizations. Reconstruction is performed (OS-EM, 40 iterations, 6 subsets) employing compensation for attenuation, scatter, and collimator-detector response. The estimated concentrations in the anthropomorphic phantom are also corrected using recovery coefficients. Errors for the largest sphere in the physical phantom range from -25% to -34% for the medium-energy collimator and larger deviations for smaller spheres. Corresponding results for the high-energy collimator are -15% to -31%. The corresponding Monte Carlo simulations show standard deviations of a few percentage points. For the anthropomorphic phantom, before application of recovery coefficients the bias ranges from -16% to -46% (medium-energy collimator) and -10% to -28% (high-energy collimator), with standard deviations of 2% to 14% and 1% to 16%. After the application of recovery coefficients, the biases range from -3% to -35% (medium energy collimator) and from 0% to -18%. The errors decrease with increasing concentrations. Activity-concentration estimation of 223Ra with SPECT is feasible, but problems with repeatability need to be further studied.
  •  
2.
  • Mínguez Gabiña, Pablo, et al. (author)
  • Activity recovery for differently shaped objects in quantitative SPECT
  • 2023
  • In: Physics in Medicine and Biology. - 0031-9155. ; 68:12
  • Journal article (peer-reviewed)abstract
    • Objective. The aim was to theoretically and experimentally investigate recovery in SPECT images with objects of different shapes. Furthermore, the accuracy of volume estimation by thresholding was studied for those shapes. Approach. Nine spheres, nine oblate spheroids, and nine prolate spheroids phantom inserts were used, of which the six smaller spheres were part of the NEMA IEC body phantom and the rest of the inserts were 3D-printed. The inserts were filled with 99mTc and 177Lu. When filled with 99mTc, SPECT images were acquired in a Siemens Symbia Intevo Bold gamma camera and when filled with 177Lu in a General Electric NM/CT 870 DR gamma camera. The signal rate per activity (SRPA) was determined for all inserts and represented as a function of the volume-to-surface ratio and of the volume-equivalent radius using VOIs defined according to the sphere dimensions and VOIs defined using thresholding. Experimental values were compared with theoretical curves obtained analytically (spheres) or numerically (spheroids), starting from the convolution of a source distribution with a point-spread function. Validation of the activity estimation strategy was performed using four 3D-printed ellipsoids. Lastly, the threshold values necessary to determine the volume of each insert were obtained. Main results. Results showed that SRPA values for the oblate spheroids diverted from the other inserts, when SRPA were represented as a function of the volume-equivalent radius. However, SRPA values for all inserts followed a similar behaviour when represented as a function of the volume-to-surface ratio. Results for ellipsoids were in agreement with those results. For the three types of inserts the volume could be accurately estimated using a threshold method for volumes larger than 25 ml. Significance. Determination of SRPA independently of lesion or organ shape should decrease uncertainties in estimated activities and thereby, in the long term, be beneficial to patient care.
  •  
3.
  • MINGUEZ GABINA, PABLO, et al. (author)
  • Whole-remnant and maximum-voxel SPECT/CT dosimetry in 131I-NaI treatments of differentiated thyroid cancer
  • 2016
  • In: Medical Physics. - : Wiley. - 0094-2405. ; 43:10, s. 5279-5287
  • Journal article (peer-reviewed)abstract
    • Purpose: To investigate the possible differences between SPECT/CT based whole-remnant and maximum-voxel dosimetry in patients receiving radio-iodine ablation treatment of differentiated thyroid cancer (DTC). Methods: Eighteen DTC patients were administered 1.11 GBq of 131I-NaI after near-total thyroidectomy and rhTSH stimulation. Two patients had two remnants, so in total dosimetry was performed for 20 sites. Three SPECT/CT scans were performed for each patient at 1, 2, and 3-7 days after administration. The activity, the remnant mass, and the maximum-voxel activity were determined from these images and from a recovery-coefficient curve derived from experimental phantom measurements. The cumulated activity was estimated using trapezoidal-exponential integration. Finally, the absorbed dose was calculated using S-values for unit-density spheres in whole-remnant dosimetry and S-values for voxels in maximum-voxel dosimetry. Results: The mean absorbed dose obtained from whole-remnant dosimetry was 40 Gy (range 2-176 Gy) and from maximum-voxel dosimetry 34 Gy (range 2-145 Gy). For any given patient, the activity concentrations for each of the three time-points were approximately the same for the two methods. The effective half-lives varied (R = 0.865), mainly due to discrepancies in estimation of the longer effective half-lives. On average, absorbed doses obtained from whole-remnant dosimetry were 1.2±0.2 (1 SD) higher than for maximum-voxel dosimetry, mainly due to differences in the S-values. The method-related differences were however small in comparison to the wide range of absorbed doses obtained in patients. Conclusions: Simple and consistent procedures for SPECT/CT based whole-volume and maximumvoxel dosimetry have been described, both based on experimentally determined recovery coefficients. Generally the results from the two approaches are consistent, although there is a small, systematic difference in the absorbed dose due to differences in the S-values, and some variability due to differences in the estimated effective half-lives, especially when the effective half-life is long. Irrespective of the method used, the patient absorbed doses obtained span over two orders of magnitude.
  •  
4.
  • Mínguez, Pablo, et al. (author)
  • Analysis of activity uptake, effective half-life and time-integrated activity for low- and high-risk papillary thyroid cancer patients treated with 1.11 GBq and 3.7 GBq of 131I-NaI respectively
  • 2019
  • In: Physica Medica. - : Elsevier BV. - 1120-1797. ; 65, s. 143-149
  • Journal article (peer-reviewed)abstract
    • Purpose: To analyse the activity uptakes, effective half-lives and time-integrated activities, of relevance for remnant dosimetry, for patients treated for papillary thyroid cancer (PTC) with a different amount of activity of 131I-NaI. Methods: Fifty patients were included. Of those, 18 patients had low-risk PTC and were treated with 1.11 GBq of 131I-NaI (Group 1), and 32 patients had high-risk PTC and were treated with 3.7 GBq (Group 2). Radioiodine was administered after total thyroidectomy and rhTSH stimulation. Two SPECT/CT scans were performed for each patient to determine the remnant activities and effective half-lives. Results: Significantly higher values (p < 0.05) were obtained for Group 1 for the remnant activity at 7 d (medians 1.4 MBq vs 0.27 MBq), the remnant activity per administered activity at 2 d (0.35% vs 0.09%) and at 7 d (0.13% vs 0.007%), and the effective half-life (93 h vs 40 h). Likewise, the time-integrated activity coefficient was significantly higher for Group 1. The time-integrated activity did not differ significantly between the two groups (p > 0.05). Conclusions: We found a significant difference in the remnant activity per administered activity, the rate of washout from thyroid remnants, and the time-integrated activity coefficient between low-risk PTC patients treated with 1.11 GBq and high-risk PTC patients treated with 3.7 GBq. On the contrary, there was no such difference in the time-integrated activity. If remnant masses were also not statistically different (reasonable assumption for this monocentric study) no difference in time-integrated activity would imply no difference in remnant absorbed dose, of relevance for treatment efficacy and the risks of stochastic effects.
  •  