SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Sinclair Donald A) "

Sökning: WFRF:(Sinclair Donald A)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Benjamin, Daniel J., et al. (författare)
  • Redefine statistical significance
  • 2018
  • Ingår i: Nature Human Behaviour. - : Nature Research (part of Springer Nature). - 2397-3374. ; 2:1, s. 6-10
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)
  •  
2.
  • Barrington, Sally F, et al. (författare)
  • PET-CT for staging and early response : results from the Response-Adapted Therapy in Advanced Hodgkin Lymphoma study.
  • 2016
  • Ingår i: Blood. - : American Society of Hematology. - 0006-4971 .- 1528-0020. ; 127:12, s. 1531-1538
  • Tidskriftsartikel (refereegranskat)abstract
    • International guidelines recommend that positron emission tomography-computed tomography (PET-CT) should replace CT in Hodgkin lymphoma (HL). The aims of this study were to compare PET-CT with CT for staging and measure agreement between expert and local readers, using a 5-point scale (Deauville criteria), to adapt treatment in a clinical trial: Response-Adapted Therapy in Advanced Hodgkin Lymphoma (RATHL). Patients were staged using clinical assessment, CT, and bone marrow biopsy (RATHL stage). PET-CT was performed at baseline (PET0) and after 2 chemotherapy cycles (PET2) in a response-adapted design. PET-CT was reported centrally by experts at 5 national core laboratories. Local readers optionally scored PET2 scans. The RATHL and PET-CT stages were compared. Agreement among experts and between expert and local readers was measured. RATHL and PET0 stage were concordant in 938 (80%) patients. PET-CT upstaged 159 (14%) and downstaged 74 (6%) patients. Upstaging by extranodal disease in bone marrow (92), lung (11), or multiple sites (12) on PET-CT accounted for most discrepancies. Follow-up of discrepant findings confirmed the PET characterization of lesions in the vast majority. Five patients were upstaged by marrow biopsy and 7 by contrast-enhanced CT in the bowel and/or liver or spleen. PET2 agreement among experts (140 scans) with a κ (95% confidence interval) of 0.84 (0.76-0.91) was very good and between experts and local readers (300 scans) at 0.77 (0.68-0.86) was good. These results confirm PET-CT as the modern standard for staging HL and that response assessment using Deauville criteria is robust, enabling translation of RATHL results into clinical practice.
  •  
3.
  • Davis, Tamara M., et al. (författare)
  • The Effect of Peculiar Velocities on Supernova Cosmology
  • 2011
  • Ingår i: Astrophysical Journal. - 0004-637X .- 1538-4357. ; 741, s. 67-
  • Tidskriftsartikel (refereegranskat)abstract
    • We analyze the effect that peculiar velocities have on the cosmological inferences we make using luminosity distance indicators, such as Type Ia supernovae. In particular we study the corrections required to account for (1) our own motion, (2) correlations in galaxy motions, and (3) a possible local under- or overdensity. For all of these effects we present a case study showing the impact on the cosmology derived by the Sloan Digital Sky Survey-II Supernova Survey (SDSS-II SN Survey). Correcting supernova (SN) redshifts for the cosmic microwave background (CMB) dipole slightly overcorrects nearby SNe that share some of our local motion. We show that while neglecting the CMB dipole would cause a shift in the derived equation of state of Δw ~ 0.04 (at fixed Ω m ), the additional local-motion correction is currently negligible (Δw <~ 0.01). We then demonstrate a covariance-matrix approach to statistically account for correlated peculiar velocities. This down-weights nearby SNe and effectively acts as a graduated version of the usual sharp low-redshift cut. Neglecting coherent velocities in the current sample causes a systematic shift of Δw ~ 0.02. This will therefore have to be considered carefully when future surveys aim for percent-level accuracy and we recommend our statistical approach to down-weighting peculiar velocities as a more robust option than a sharp low-redshift cut.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy