SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Suzuki Marcelo) "

Search: WFRF:(Suzuki Marcelo)

  • Result 1-10 of 13
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • 2017
  • swepub:Mat__t
  •  
2.
  • Abazajian, Kevork, et al. (author)
  • CMB-S4 : Forecasting Constraints on Primordial Gravitational Waves
  • 2022
  • In: Astrophysical Journal. - : American Astronomical Society. - 0004-637X .- 1538-4357. ; 926:1
  • Journal article (peer-reviewed)abstract
    • CMB-S4—the next-generation ground-based cosmic microwave background (CMB) experiment—is set to significantly advance the sensitivity of CMB measurements and enhance our understanding of the origin and evolution of the universe. Among the science cases pursued with CMB-S4, the quest for detecting primordial gravitational waves is a central driver of the experimental design. This work details the development of a forecasting framework that includes a power-spectrum-based semianalytic projection tool, targeted explicitly toward optimizing constraints on the tensor-to-scalar ratio, r, in the presence of Galactic foregrounds and gravitational lensing of the CMB. This framework is unique in its direct use of information from the achieved performance of current Stage 2–3 CMB experiments to robustly forecast the science reach of upcoming CMB-polarization endeavors. The methodology allows for rapid iteration over experimental configurations and offers a flexible way to optimize the design of future experiments, given a desired scientific goal. To form a closed-loop process, we couple this semianalytic tool with map-based validation studies, which allow for the injection of additional complexity and verification of our forecasts with several independent analysis methods. We document multiple rounds of forecasts for CMB-S4 using this process and the resulting establishment of the current reference design of the primordial gravitational-wave component of the Stage-4 experiment, optimized to achieve our science goals of detecting primordial gravitational waves for r > 0.003 at greater than 5σ, or in the absence of a detection, of reaching an upper limit of r < 0.001 at 95% CL.
  •  
3.
  • Ade, Peter, et al. (author)
  • The Simons Observatory : science goals and forecasts
  • 2019
  • In: Journal of Cosmology and Astroparticle Physics. - : IOP Publishing. - 1475-7516. ; :2
  • Journal article (peer-reviewed)abstract
    • The Simons Observatory (SO) is a new cosmic microwave background experiment being built on Cerro Toco in Chile, due to begin observations in the early 2020s. We describe the scientific goals of the experiment, motivate the design, and forecast its performance. SO will measure the temperature and polarization anisotropy of the cosmic microwave background in six frequency bands centered at: 27, 39, 93, 145, 225 and 280 GHz. The initial con figuration of SO will have three small-aperture 0.5-m telescopes and one large-aperture 6-m telescope, with a total of 60,000 cryogenic bolometers. Our key science goals are to characterize the primordial perturbations, measure the number of relativistic species and the mass of neutrinos, test for deviations from a cosmological constant, improve our understanding of galaxy evolution, and constrain the duration of reionization. The small aperture telescopes will target the largest angular scales observable from Chile, mapping approximate to 10% of the sky to a white noise level of 2 mu K-arcmin in combined 93 and 145 GHz bands, to measure the primordial tensor-to-scalar ratio, r, at a target level of sigma(r) = 0.003. The large aperture telescope will map approximate to 40% of the sky at arcminute angular resolution to an expected white noise level of 6 mu K-arcmin in combined 93 and 145 GHz bands, overlapping with the majority of the Large Synoptic Survey Telescope sky region and partially with the Dark Energy Spectroscopic Instrument. With up to an order of magnitude lower polarization noise than maps from the Planck satellite, the high-resolution sky maps will constrain cosmological parameters derived from the damping tail, gravitational lensing of the microwave background, the primordial bispectrum, and the thermal and kinematic Sunyaev-Zel'dovich effects, and will aid in delensing the large-angle polarization signal to measure the tensor-to-scalar ratio. The survey will also provide a legacy catalog of 16,000 galaxy clusters and more than 20,000 extragalactic sources.
  •  
4.
  • Bonfante, Estevam Augusto, et al. (author)
  • Biomechanical testing of microblasted, acid-etched/microblasted, anodized, and discrete crystalline deposition surfaces : an experimental study in beagle dogs
  • 2013
  • In: International Journal of Oral & Maxillofacial Implants. - : Quintessence. - 0882-2786 .- 1942-4434. ; 28:1, s. 136-142
  • Journal article (peer-reviewed)abstract
    • PURPOSE: Modifications in implant surface topography and chemistry may alter the early bone response at different levels. This study characterized four implant surfaces and evaluated the biomechanical fixation and histologic response at early implantation times in a canine radius model. MATERIALS AND METHODS: External-hexagon Branemark-type implants were used with four experimental surfaces: microblasted (MI), acid-etched and microblasted (AAM), anodized (A), and discrete crystalline deposition (DCD). Surface topography was assessed by scanning electron microscopy, interferometry, and x-ray photoelectron spectroscopy. The implants were placed in the central region of the radii of eight beagle dogs and remained in vivo for 10 or 30 days. The implants were torqued to interface failure, and a general linear statistical model with torque as the dependent variable and implant surface and time in vivo as independent variables was used. RESULTS: All surfaces presented were textured, and different surface chemistries were observed. No significant differences between implant surfaces were observed for torque at 10 days. However, at 30 days, the AAM surface presented significantly higher torque values compared to the DCD and A surfaces. Significantly higher torque values were observed at 30 days compared to 10 days (P < .001). CONCLUSIONS: Significantly different biomechanical fixation dependent on surface preparation was observed after 30 days, and all surfaces were biocompatible and osteoconductive.
  •  
5.
  • Coelho, Paulo G, et al. (author)
  • Effect of Si addition on Ca- and P-impregnated implant surfaces with nanometer-scale roughness: an experimental study in dogs.
  • 2012
  • In: Clinical oral implants research. - : Wiley. - 1600-0501 .- 0905-7161.
  • Journal article (peer-reviewed)abstract
    • Objectives: To investigate the effect of Si addition on a nanometer-scale roughness Ca and P implant surfaces in a canine tibia model by biomechanical and histomorphometric evaluations. Material and methods: The implant surfaces comprised a resorbable media CaP microblasted (control) and a CaP resorbable media+silica-boost microblasted (experimental) surfaces. Surfaces were characterized by scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), and optical interferometry (IFM) down to the nanometric level. The animal model involved the bilateral placement of control (n=24) and experimental surface (n=24) implants along the proximal tibiae of six dogs, remaining in vivo for 2 or 4 weeks. After euthanization, half of the specimens were torqued-to-interface failure, and the other half was subjected to histomorphologic and bone-to-implant contact (BIC) evaluation. Torque and BIC statistical evaluation was performed by the Friedman test at 95% level of significance, and comparisons between groups was performed by the Dunn test. Results: IFM and SEM observations depicted comparable roughness parameters for both implant surfaces on the micrometer and nanometer scales. XPS analysis revealed similar chemical composition, except for the addition of Si on the experimental group. Torque-to-interface failure and BIC mean values showed no significant differences (P=0.25 and 0.51, respectively) at both 2- and 4-week evaluation points for experimental and control groups. Early bone healing histomorphologic events were similar between groups. Conclusions: The experimental surface resulted in not significantly different biomechanical fixation and BIC relative to control. Both surfaces were biocompatible and osseoconductive. To cite this article: Coelho PG, Granato R, Marin C, Jimbo R, Lin S, Witek L, Suzuki M, Bonfante EA. Effect of Si addition on Ca- and P-impregnated implant surfaces with nanometer-scale roughness: an experimental study in dogs. Clin. Oral Impl. Res. xx, 2011; 000-000. doi: 10.1111/j.1600-0501.2010.02150.x.
  •  
6.
  • Coelho, Paulo G., et al. (author)
  • Osseointegration of Plateau Root Form Implants : Unique Healing Pathway Leading to Haversian-Like Long-Term Morphology
  • 2015
  • In: Engineering Mineralized and Load Bearing Tissue. - Cham : Springer. - 9783319223452 - 9783319223445 ; , s. 111-128
  • Book chapter (other academic/artistic)abstract
    • Endosteal dental implants have been utilized as anchors for dental and orthopedic rehabilitations for decades with one of the highest treatment success rates in medicine. Such success is due to the phenomenon of osseointegration where after the implant surgical placement, bone healing results into an intimate contact between bone and implant surface. While osseointegration is an established phenomenon, the route which osseointegration occurs around endosteal implants is related to various implant design factors including surgical instrumentation and implant macro, micro, and nanometer scale geometry. In an implant system where void spaces (healing chambers) are present between the implant and bone immediately after placement, its inherent bone healing pathway results in unique opportunities to accelerate the osseointegration phenomenon at the short-term and its maintenance on the long-term through a haversian-like bone morphology and mechanical properties.
  •  
7.
  • Gil, Luiz F., et al. (author)
  • Progressive plateau root form dental implant osseointegration : a human retrieval study
  • 2015
  • In: Journal of Biomedical Materials Research. Part B - Applied biomaterials. - : John Wiley & Sons. - 1552-4973 .- 1552-4981. ; 103:6, s. 1328-1332
  • Journal article (peer-reviewed)abstract
    • Although preclinical and sparse human histology retrieval studies have shown that the interface between implant and bone is constantly remodeling, no human retrieval database has been developed to determine the effect of functional loading time and other clinical/implant design variables on osseointegration. The present study tested the hypothesis that bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO) increase over functional loading time around dental implants. Due to prosthetic retreatment reasons, 93 human implant retrievals from the same manufacturer (Bicon LLC, Boston, MA, USA) were obtained over a period of approximately 15 years. The retrieved implants were under functional loading from 120 days to approximate to 18 years and were histomorphologic/metrically evaluated. BIC/BAFO were assessed as a function of multiple independent variables: implant surface type, diameter, length, jaw (maxilla/mandible), region (anterior/posterior), and time of functional loading. The results showed that both BIC and BAFO increased over time independently of implant design/clinical variables, supporting the postulated hypothesis. (c) 2014 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 103B: 1328-1332, 2015.
  •  
8.
  • Giro, Gabriela, et al. (author)
  • The effect of simplifying dental implant drilling sequence on osseointegration : an experimental study in dogs
  • 2013
  • In: International Journal of Biomaterials. - : Hindawi Publishing Corporation. - 1687-8787 .- 1687-8795. ; 2013
  • Journal article (peer-reviewed)abstract
    • Objectives. To test the hypothesis that there would be no differences in osseointegration by reducing the number of drills for site preparation relative to conventional drilling sequence. Methods. Seventy-two implants were bilaterally placed in the tibia of 18 beagle dogs and remained for 1, 3, and 5 weeks. Thirty-six implants were 3.75 mm in diameter and the other 36 were 4.2 mm. Half of the implants of each diameter were placed under a simplified technique (pilot drill + final diameter drill) and the other half were placed under conventional drilling where multiple drills of increasing diameter were utilized. After euthanisation, the bone-implant samples were processed and referred to histological analysis. Bone-to-implant contact (BIC) and bone-area-fraction occupancy (BAFO) were assessed. Statistical analyses were performed by GLM ANOVA at 95% level of significance considering implant diameter, time in vivo, and drilling procedure as independent variables and BIC and BAFO as the dependent variables. Results. Both techniques led to implant integration. No differences in BIC and BAFO were observed between drilling procedures as time elapsed in vivo. Conclusions. The simplified drilling protocol presented comparable osseointegration outcomes to the conventional protocol, which proved the initial hypothesis.
  •  
9.
  • Jimbo, Ryo, et al. (author)
  • Bone Morphometric Evaluation around Immediately Placed Implants Covered with Porcine-Derived Pericardium Membrane : An Experimental Study in Dogs
  • 2012
  • In: International Journal of Biomaterials. - : Hindawi Publishing Corporation. - 1687-8787 .- 1687-8795. ; 2012
  • Journal article (peer-reviewed)abstract
    • Objective. To investigate whether porcine-derived bioresorbable pericardium membrane coverage enhances the osseointegration around implants placed in fresh extraction sockets. Study Design. Twenty-four commercially available endosseous implants were placed in the fresh extraction sockets of the mandibular first molar of mature beagles (n = 6). On one side, implants and osteotomy sites were covered with porcine-derived bioresorbable pericardium membranes, whereas on the other side, no membranes were used. After 6 weeks, samples were retrieved and were histologically processed for histomorphometric analysis. Results. The histological observation showed that bone loss and soft tissue migration in the coronal region of the implant were evident for the control group, whereas bone fill was evident up to the neck of the implant for the membrane-covered group. Bone-to-implant contact was significantly higher for the membrane-covered group compared to the control group, 75% and 45% (P < 0.02), respectively. Conclusion. The experimental membranes proved to regenerate bone around implants placed in fresh extraction sockets without soft tissue intrusion.
  •  
10.
  • Jimbo, Ryo, et al. (author)
  • Simplified drilling technique does not decrease dental implant osseointegration : a preliminary report
  • 2013
  • In: Journal of Periodontology. - : American Academy of Periodontology. - 0022-3492 .- 1943-3670. ; 84:11, s. 1599-1605
  • Journal article (peer-reviewed)abstract
    • Background: To date, some experimental studies have addressed the effect of bone drilling technique and sequence on dental implant osseointegration. In the present study, the authors hypothesize that there would be no differences in osseointegration when reducing the number of drills for osteotomy compared to the conventional drilling protocols. Methods: Seventy-two implants (diameters 3.75 mm and 4.2 mm; n = 36 for each diameter) were bilaterally placed in the tibia of 18 beagles for 1, 3, and 5 weeks. Half of the implants of each diameter were placed using a simplified drilling procedure (pilot and final drill), and the other half were placed using a conventional drilling procedure (all drills in sequence). The retrieved samples were subjected to histologic and histomorphometric evaluation. Results: Histology showed that new bone formed around the implant, and inflammation or bone resorption was not evident for both groups. Histomorphometrically, the simplified group presented significantly higher bone-to-implant contact and bone area fraction occupancy compared to the conventional group after 1 week; however, no differences were detected at 3 and 5 weeks. Conclusion: Bone responses to the implant with the simplified protocol can be comparable to the conventional protocol.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-10 of 13

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view