SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Vaida M) "

Sökning: WFRF:(Vaida M)

  • Resultat 1-10 av 12
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Kanai, M, et al. (författare)
  • 2023
  • swepub:Mat__t
  •  
2.
  •  
3.
  •  
4.
  •  
5.
  • Felde, Vivian A., et al. (författare)
  • Compositional turnover and variation in Eemian pollen sequences in Europe
  • 2020
  • Ingår i: Vegetation History and Archaeobotany. - : Springer Science and Business Media LLC. - 0939-6314 .- 1617-6278. ; 29:1, s. 101-109
  • Tidskriftsartikel (refereegranskat)abstract
    • The Eemian interglacial represents a natural experiment on how past vegetation with negligible human impact responded to amplified temperature changes compared to the Holocene. Here, we assemble 47 carefully selected Eemian pollen sequences from Europe to explore geographical patterns of (1) total compositional turnover and total variation for each sequence and (2) stratigraphical turnover between samples within each sequence using detrended canonical correspondence analysis, multivariate regression trees, and principal curves. Our synthesis shows that turnover and variation are highest in central Europe (47-55 degrees N), low in southern Europe (south of 45 degrees N), and lowest in the north (above 60 degrees N). These results provide a basis for developing hypotheses about causes of vegetation change during the Eemian and their possible drivers.
  •  
6.
  •  
7.
  • Anderson, Albert M, et al. (författare)
  • Cerebrospinal fluid CXCL10 is associated with the presence of low level CSF HIV during suppressive antiretroviral therapy.
  • 2021
  • Ingår i: Journal of neuroimmunology. - : Elsevier BV. - 1872-8421 .- 0165-5728. ; 353
  • Tidskriftsartikel (refereegranskat)abstract
    • Surrogate markers of HIV central nervous system (CNS) persistence are needed because direct HIV measurements from the CNS require specialized protocols and are not always detectable or quantifiable. We analyzed paired plasma and CSF samples from people with HIV (PWH) on suppressive therapy (ART) with a validated HIV single copy RNA assay. Two potential markers of CNS persistence were measured (CXCL10 and sCD30). We then examined associations with CSF HIV RNA positivity in univariable and multivariable analyses. Among 66 individuals, 18.2% had detectable CSF HIV. Individuals who had detectable HIV in CSF had higher CSF CXCL10 concentrations (median 514pg/ml versus median 317pg/ml, p=0.019), but did not have significantly different CSF sCD30 concentrations (median 7.5ng/ml versus median 7.6ng/ml, p=0.78). In the multiple logistic analysis, both higher CSF CXCL10 (p=0.038) and plasma HIV detectability (p=0.035) were significantly associated with detectable CSF HIV. Both sCD30 and CXCL10 correlated positively with NfL and NSE, two neuronal markers. This study demonstrates that CSF CXCL10 concentrations reflect low level HIV CNS persistence despite virologic suppression on ART. Given that it is readily detectable and quantifiable, this chemokine may be a promising biomarker to evaluate HIV eradication therapies that target the CNS.
  •  
8.
  • Pallon, Jan, et al. (författare)
  • An off-axis STIM procedure for precise mass determination and imaging
  • 2004
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms. - : Elsevier BV. - 0168-583X. ; 219-20, s. 988-993
  • Tidskriftsartikel (refereegranskat)abstract
    • For the precise determination of the local mass density in thin samples analysed at the Lund Nuclear Microprobe, a modified version of off-axis STIM is described. An on-axis/off-axis geometry is used where a thin C-foil, placed behind the sample scatters protons into the particle detector. The advantage of this geometry compared to the off-axis case where particles are directly scattered from the sample into the particle detector is that the energy-loss spectrum acquired is less degraded. A spectral resolution comparable to on-axis STIM is achieved at a beam current high enough to allow for a simultaneous PIXE analysis (50-100 pA). (C) 2004 Elsevier B.V. All rights reserved.
  •  
9.
  • Pearce, Elena A., et al. (författare)
  • Substantial light woodland and open vegetation characterized the temperate forest biome before Homo sapiens
  • 2023
  • Ingår i: Science Advances. - 2375-2548. ; 9:45
  • Tidskriftsartikel (refereegranskat)abstract
    • The extent of vegetation openness in past European landscapes is widely debated. In particular, the temperate forest biome has traditionally been defined as dense, closed-canopy forest; however, some argue that large herbivores maintained greater openness or even wood-pasture conditions. Here, we address this question for the Last Interglacial period (129,000–116,000 years ago), before Homo sapiens–linked megafauna declines and anthropogenic landscape transformation. We applied the vegetation reconstruction method REVEALS to 96 Last Interglacial pollen records. We found that light woodland and open vegetation represented, on average, more than 50% cover during this period. The degree of openness was highly variable and only partially linked to climatic factors, indicating the importance of natural disturbance regimes. Our results show that the temperate forest biome was historically heterogeneous rather than uniformly dense, which is consistent with the dependency of much of contemporary European biodiversity on open vegetation and light woodland.
  •  
10.
  • Rossi, P, et al. (författare)
  • Performance of an alpha-IPEM
  • 2006
  • Ingår i: Ion Beam Analysis - Proceedings of the Seventeenth International Conference on Ion Beam Analysis (Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms). - : Elsevier BV. - 0168-583X. ; 249, s. 242-245
  • Konferensbidrag (refereegranskat)abstract
    • The ion photon emission microscope, or IPEM, is the first device that allows scientists to microscopically study the effects of single ions in air on semiconductors, microchips and even biological cells without having to focus the beam. Reported here is a prototype, the size of a conventional optical microscope, developed at Sandia. The alpha-IPEM, that employs alpha particles from a radioactive source, represents the first example of IBA imaging without an accelerator. The IPEM resolution is currently limited to similar to 10 mu m, but we also report a gridded-phosphor approach that could improve this resolution to that of the optical microscope, or similar to 1 mu m. Finally, we propose that a simple adaptation of the alpha-IPEM could be the only way to maintain the high utility of radiation effects microscopy into the future.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 12

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy