SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Zadpoor A. A.) "

Sökning: WFRF:(Zadpoor A. A.)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Amin Yavari, S., et al. (författare)
  • Layer by layer coating for bio-functionalization of additively manufactured meta-biomaterials
  • 2020
  • Ingår i: Additive Manufacturing. - : Elsevier BV. - 2214-8604 .- 2214-7810. ; 32
  • Tidskriftsartikel (refereegranskat)abstract
    • Additive manufacturing has facilitated fabrication of complex and patient-specific metallic meta-biomaterials that offer an unprecedented collection of mechanical, mass transport, and biological properties as well as a fully interconnected porous structure. However, applying meta-biomaterials for addressing unmet clinical needs in orthopedic surgery requires additional surface functionalities that should be induced through tailor-made coatings. Here, we developed multi-functional layer-by-layer coatings to simultaneously prevent implant-associated infections and stimulate bone tissue regeneration. We applied multiple layers of gelatin- and chitosan-based coatings containing either bone morphogenetic protein (BMP)-2 or vancomycin on the surface of selective laser melted porous structures made from commercial pure Titanium (CP Ti) and designed using a triply periodic minimal surface (i.e., sheet gyroid). The additive manufacturing process resulted in a porous structure and met the the design values comparatively. X-ray photoelectron spectroscopy spectra confirmed the presence and composition of the coating layers. The release profiles showed a continued release of both vancomycin and BMP-2 for 2–3 weeks. Furthermore, the developed meta-biomaterials exhibited a very strong antibacterial behavior with up to 8 orders of magnitude reduction in both planktonic and implant-adherent bacteria and no signs of biofilm formation. The osteogenic differentiation of mesenchymal stem cells was enhanced, as shown by two-fold increase in the alkaline phosphatase activity and up to four-fold increase in the mineralization of all experimental groups containing BMP-2. Eight-week subcutaneous implantation in vivo showed no signs of a foreign body response, while connective tissue ingrowth was promoted by the layer-by-layer coating. These results unequivocally confirm the superior multi-functional performance of the developed biomaterials.
  •  
2.
  •  
3.
  • Grassi, Lorenzo, et al. (författare)
  • Experimental Validation Of Finite Element Model For Proximal Composite Femur Using Optical Measurements
  • 2013
  • Ingår i: Journal of the Mechanical Behavior of Biomedical Materials. - : Elsevier BV. - 1751-6161. ; 21, s. 86-94
  • Tidskriftsartikel (refereegranskat)abstract
    • Patient-specific finite element models have been used to predict femur strength and fracture risk in individuals. Validation of the adopted finite element modelling procedure against mechanical testing data is a crucial step when aiming for clinical applications. The majority of the works available in literature used data from strain gages to validate the model, thus having up to 15 experimental measurements. Optical techniques, such as Digital Image Correlation, can help to improve the models by providing a continuous field of deformation data over a femoral surface. The main objective of this study was to validate finite element models of six composite femora against strain data from digital image correlation, obtained during fracture tests performed in quasi-axial loading configuration. The finite element models were obtained from CT scans, by means of a semi-automatic segmentation. The principal strains both during the elastic phase and close to the fracture were compared, and showed a correlation coefficient close to 0.9. In the linear region, the slope and intercept were close to zero and unity, while for the case when fracture load was simulated, the slope decreased somewhat. The accuracy of the obtained results is comparable with the state-of-the-art literature, with the significant improvement of having around 50000 data points for each femur. This large number of measurements allows a more comprehensive validation of the predictions by the finite element models, since thousand of points are tracked along the femoral neck and trochanter region, i.e., the sites that are most critical for femur fracture. Moreover, strain measurement biases due to the strain gage reinforcement effect, were avoided. The combined experimental-numerical approach proved to be ready for application to in-vitro tests of human cadaver femurs, thus helping to develop a suitable mechanistic fracture risk criterion.
  •  
4.
  • Grassi, Lorenzo, et al. (författare)
  • Full-field Strain Measurement During Mechanical Testing of the Human Femur at Physiologically Relevant Strain Rates
  • 2014
  • Ingår i: Journal of Biomechanical Engineering. - : ASME International. - 0148-0731 .- 1528-8951. ; 136:11
  • Tidskriftsartikel (refereegranskat)abstract
    • Understanding the mechanical properties of human femora is of great importance for the development of a reliable fracture criterion aimed at assessing fracture risk. Earlier ex vivo studies have been conducted by measuring strains on a limited set of locations using strain gauges. Digital Image Correlation (DIC) could instead be used to reconstruct the full-field strain pattern over the surface of the femur. The objective of this study was to measure the full-field strain response of cadaver femora tested at a physiological strain rate up to fracture in a configuration resembling single stance. The three cadaver femora were cleaned from soft tissues, and a white background paint was applied with a random black speckle pattern over the anterior surface. The mechanical tests were conducted up to fracture at a constant displacement rate of 15 mm/s, and two cameras recorded the event at 3000 frames per second. DIC was performed to retrieve the full-field displacement map, from which strains were derived. A low-pass filter was applied over the measured displacements before the crack opened in order to reduce the noise level. The noise levels were assessed using a dedicated control plate. Conversely, no filtering was applied at the frames close to fracture to get the maximum resolution. The specimens showed a linear behavior of the principal strains with respect to the applied force up to fracture. The strain rate was comparable to the values available in literature from in-vivo measurements during daily activities. The cracks opened and fully propagated in less than 1 ms, and small regions with high values of the major principal strains could be spotted just a few frames before the crack opened. This corroborates the hypothesis of a strain-driven fracture mechanism in human bone. The data represents a comprehensive collection of full-field strains, both at physiological load levels and up to fracture. About 10000 measurements were collected for each bone, providing superior spatial resolution compared to ~15 measurements typically collected using strain gauges. These experimental data collection can be further used for validation of numerical models, and for experimental verification of bone constitutive laws and fracture criteria.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy