  • Bluth, T., et al. (författare)
  • Protective intraoperative ventilation with higher versus lower levels of positive end-expiratory pressure in obese patients (PROBESE) : study protocol for a randomized controlled trial
  • 2017
  • Ingår i: Trials. - : Springer Science and Business Media LLC. - 1745-6215. ; 18
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Postoperative pulmonary complications (PPCs) increase the morbidity and mortality of surgery in obese patients. High levels of positive end-expiratory pressure (PEEP) with lung recruitment maneuvers may improve intraoperative respiratory function, but they can also compromise hemodynamics, and the effects on PPCs are uncertain. We hypothesized that intraoperative mechanical ventilation using high PEEP with periodic recruitment maneuvers, as compared with low PEEP without recruitment maneuvers, prevents PPCs in obese patients.Methods/design: The PRotective Ventilation with Higher versus Lower PEEP during General Anesthesia for Surgery in OBESE Patients (PROBESE) study is a multicenter, two-arm, international randomized controlled trial. In total, 2013 obese patients with body mass index >= 35 kg/m(2) scheduled for at least 2 h of surgery under general anesthesia and at intermediate to high risk for PPCs will be included. Patients are ventilated intraoperatively with a low tidal volume of 7 ml/kg (predicted body weight) and randomly assigned to PEEP of 12 cmH(2)O with lung recruitment maneuvers (high PEEP) or PEEP of 4 cmH(2)O without recruitment maneuvers (low PEEP). The occurrence of PPCs will be recorded as collapsed composite of single adverse pulmonary events and represents the primary endpoint.Discussion: To our knowledge, the PROBESE trial is the first multicenter, international randomized controlled trial to compare the effects of two different levels of intraoperative PEEP during protective low tidal volume ventilation on PPCs in obese patients. The results of the PROBESE trial will support anesthesiologists in their decision to choose a certain PEEP level during general anesthesia for surgery in obese patients in an attempt to prevent PPCs.
  •  
10.
  •  
11.
  •  
12.
  •  
13.
  • Bluth, Thomas, et al. (författare)
  • Effect of Intraoperative High Positive End-Expiratory Pressure (PEEP) With Recruitment Maneuvers vs Low PEEP on Postoperative Pulmonary Complications in Obese Patients : A Randomized Clinical Trial.
  • 2019
  • Ingår i: Journal of the American Medical Association (JAMA). - : American Medical Association (AMA). - 0098-7484 .- 1538-3598. ; 321:23, s. 2292-2305
  • Tidskriftsartikel (refereegranskat)abstract
    • Importance: An intraoperative higher level of positive end-expiratory positive pressure (PEEP) with alveolar recruitment maneuvers improves respiratory function in obese patients undergoing surgery, but the effect on clinical outcomes is uncertain.Objective: To determine whether a higher level of PEEP with alveolar recruitment maneuvers decreases postoperative pulmonary complications in obese patients undergoing surgery compared with a lower level of PEEP.Design, Setting, and Participants: Randomized clinical trial of 2013 adults with body mass indices of 35 or greater and substantial risk for postoperative pulmonary complications who were undergoing noncardiac, nonneurological surgery under general anesthesia. The trial was conducted at 77 sites in 23 countries from July 2014-February 2018; final follow-up: May 2018.Interventions: Patients were randomized to the high level of PEEP group (n = 989), consisting of a PEEP level of 12 cm H2O with alveolar recruitment maneuvers (a stepwise increase of tidal volume and eventually PEEP) or to the low level of PEEP group (n = 987), consisting of a PEEP level of 4 cm H2O. All patients received volume-controlled ventilation with a tidal volume of 7 mL/kg of predicted body weight.Main Outcomes and Measures: The primary outcome was a composite of pulmonary complications within the first 5 postoperative days, including respiratory failure, acute respiratory distress syndrome, bronchospasm, new pulmonary infiltrates, pulmonary infection, aspiration pneumonitis, pleural effusion, atelectasis, cardiopulmonary edema, and pneumothorax. Among the 9 prespecified secondary outcomes, 3 were intraoperative complications, including hypoxemia (oxygen desaturation with Spo2 ≤92% for >1 minute).Results: Among 2013 adults who were randomized, 1976 (98.2%) completed the trial (mean age, 48.8 years; 1381 [69.9%] women; 1778 [90.1%] underwent abdominal operations). In the intention-to-treat analysis, the primary outcome occurred in 211 of 989 patients (21.3%) in the high level of PEEP group compared with 233 of 987 patients (23.6%) in the low level of PEEP group (difference, -2.3% [95% CI, -5.9% to 1.4%]; risk ratio, 0.93 [95% CI, 0.83 to 1.04]; P = .23). Among the 9 prespecified secondary outcomes, 6 were not significantly different between the high and low level of PEEP groups, and 3 were significantly different, including fewer patients with hypoxemia (5.0% in the high level of PEEP group vs 13.6% in the low level of PEEP group; difference, -8.6% [95% CI, -11.1% to 6.1%]; P < .001).Conclusions and Relevance: Among obese patients undergoing surgery under general anesthesia, an intraoperative mechanical ventilation strategy with a higher level of PEEP and alveolar recruitment maneuvers, compared with a strategy with a lower level of PEEP, did not reduce postoperative pulmonary complications.Trial Registration: ClinicalTrials.gov Identifier: NCT02148692.
  •  
14.
  • Huijben, Jilske A., et al. (författare)
  • Development of a quality indicator set to measure and improve quality of ICU care for patients with traumatic brain injury
  • 2019
  • Ingår i: Critical Care. - : BioMed Central. - 1364-8535 .- 1466-609X. ; 23
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: We aimed to develop a set of quality indicators for patients with traumatic brain injury (TBI) in intensive care units (ICUs) across Europe and to explore barriers and facilitators for implementation of these quality indicators.Methods: A preliminary list of 66 quality indicators was developed, based on current guidelines, existing practice variation, and clinical expertise in TBI management at the ICU. Eight TBI experts of the Advisory Committee preselected the quality indicators during a first Delphi round. A larger Europe-wide expert panel was recruited for the next two Delphi rounds. Quality indicator definitions were evaluated on four criteria: validity (better performance on the indicator reflects better processes of care and leads to better patient outcome), feasibility (data are available or easy to obtain), discriminability (variability in clinical practice), and actionability (professionals can act based on the indicator). Experts scored indicators on a 5-point Likert scale delivered by an electronic survey tool.Results. The expert panel consisted of 50 experts from 18 countries across Europe, mostly intensivists (N=24, 48%) and neurosurgeons (N=7, 14%). Experts agreed on a final set of 42 indicators to assess quality of ICU care: 17 structure indicators, 16 process indicators, and 9 outcome indicators. Experts are motivated to implement this finally proposed set (N=49, 98%) and indicated routine measurement in registries (N=41, 82%), benchmarking (N=42, 84%), and quality improvement programs (N=41, 82%) as future steps. Administrative burden was indicated as the most important barrier for implementation of the indicator set (N=48, 98%).Conclusions: This Delphi consensus study gives insight in which quality indicators have the potential to improve quality of TBI care at European ICUs. The proposed quality indicator set is recommended to be used across Europe for registry purposes to gain insight in current ICU practices and outcomes of patients with TBI. This indicator set may become an important tool to support benchmarking and quality improvement programs for patients with TBI in the future.
  •  