SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "hsv:(TEKNIK OCH TEKNOLOGIER) hsv:(Medicinteknik) hsv:(Medicinsk bildbehandling) "

Sökning: hsv:(TEKNIK OCH TEKNOLOGIER) hsv:(Medicinteknik) hsv:(Medicinsk bildbehandling)

  • Resultat 1-25 av 1733
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Abbaspour, S., et al. (författare)
  • Real-Time and Offline Evaluation of Myoelectric Pattern Recognition for the Decoding of Hand Movements
  • 2021
  • Ingår i: Sensors. - : MDPI AG. - 1424-8220. ; 21:16
  • Tidskriftsartikel (refereegranskat)abstract
    • Pattern recognition algorithms have been widely used to map surface electromyographic signals to target movements as a source for prosthetic control. However, most investigations have been conducted offline by performing the analysis on pre-recorded datasets. While real-time data analysis (i.e., classification when new data becomes available, with limits on latency under 200-300 milliseconds) plays an important role in the control of prosthetics, less knowledge has been gained with respect to real-time performance. Recent literature has underscored the differences between offline classification accuracy, the most common performance metric, and the usability of upper limb prostheses. Therefore, a comparative offline and real-time performance analysis between common algorithms had yet to be performed. In this study, we investigated the offline and real-time performance of nine different classification algorithms, decoding ten individual hand and wrist movements. Surface myoelectric signals were recorded from fifteen able-bodied subjects while performing the ten movements. The offline decoding demonstrated that linear discriminant analysis (LDA) and maximum likelihood estimation (MLE) significantly (p < 0.05) outperformed other classifiers, with an average classification accuracy of above 97%. On the other hand, the real-time investigation revealed that, in addition to the LDA and MLE, multilayer perceptron also outperformed the other algorithms and achieved a classification accuracy and completion rate of above 68% and 69%, respectively.
  •  
2.
  • Lui, Hoi-Shun, et al. (författare)
  • On the matching medium for microwave stroke diagnosis
  • 2019
  • Ingår i: Biomedical Physics and Engineering Express. - : IOP Publishing. - 2057-1976. ; 5:4
  • Tidskriftsartikel (refereegranskat)abstract
    • The choice of matching medium can directly affect the amount of power transmitted into and through human bodies, which impacts on the quality of the reconstructed images in microwave-based medical imaging, and thus the diagnosis accuracies. In this paper, the amount of the transmitted and reflected power of multi-layer planar healthy and hemorrhagic stroke brain models under different choices of matching medium are determined. These multi-layer planar brain tissue models are made up of at least 17 tissue layers with realistic dielectric properties. A layer of blood with different thickness is introduced to model the case of hemorrhagic stroke. Our results show that matching medium with low relative permittivity provides better intrinsic contrast between healthy brain and hemorrhagic brain. Analysis on how the reflection coefficient and transmittance vary under different matching medium are included to provide better insights to the findings.
  •  
3.
  • Khodadad, Davood, 1985-, et al. (författare)
  • Optimized breath detection algorithm in electrical impedance tomography
  • 2018
  • Ingår i: Physiological Measurement. - : IOP Publishing. - 0967-3334 .- 1361-6579. ; 39:9
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: This paper defines a method for optimizing the breath delineation algorithms used in electrical impedance tomography (EIT). In lung EIT the identification of the breath phases is central for generating tidal impedance variation images, subsequent data analysis and clinical evaluation. The optimisation of these algorithms is particularly important in neonatal care since the existing breath detectors developed for adults may give insufficient reliability in neonates due to their very irregular breathing pattern.Approach: Our approach is generic in the sense that it relies on the definition of a gold standard and the associated definition of detector sensitivity and specificity, an optimisation criterion and a set of detector parameters to be investigated. The gold standard has been defined by 11 clinicians with previous experience with EIT and the performance of our approach is described and validated using a neonatal EIT dataset acquired within the EU-funded CRADL project.Main results: Three different algorithms are proposed that improve the breath detector performance by adding conditions on (1) maximum tidal breath rate obtained from zero-crossings of the EIT breathing signal, (2) minimum tidal impedance amplitude and (3) minimum tidal breath rate obtained from time-frequency analysis. As a baseline a zero-crossing algorithm has been used with some default parameters based on the Swisstom EIT device.Significance: Based on the gold standard, the most crucial parameters of the proposed algorithms are optimised by using a simple exhaustive search and a weighted metric defined in connection with the receiver operating characterics. This provides a practical way to achieve any desirable trade-off between the sensitivity and the specificity of the detectors.
  •  
4.
  • Bondesson, Johan, 1991, et al. (författare)
  • Definition of Tubular Anatomic Structures from Arbitrary Stereo Lithographic Surface
  • 2017
  • Ingår i: Initiative Seminar Engineering Health, 8-9 November 2017, Chalmers.
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
    • An accurate description of anatomies and dynamics of vessels is crucial to understand their characteristics and improve surgical techniques, thus it is the basis, in addition to surgeon experience, on which stent design and operation procedures rely. The process of producing this description is user intensive, and recent improvement in image processing of medical3D imaging allows for a more automated workflow. However, there is a need to bridge the gap from a processed geometry to a robust mathematical computational grid. By sequentially segmenting a tubular anatomic structure, here defined by a stereo lithographic (STL) surface, an initial centerline is formed by connecting centroids of orthogonal cross-sectional contours along the length of the structure. Relying on the initial centerline, a set of non-overlapping 2D cross sectional contours are defined along the centerline, a centerline which is updated after the 2D contours are produced. After a second iteration of producing 2D contours and updating the centerline, a full description of the structure is created. Our method for describing vessel geometry shows good coherence to existing method. The main advantages of our method include the possibility of having arbitrary triangulated STL surface input, automated centerline definition, safety against intersecting cross-sectional contours and automatic clean-up of local kinks and wrinkles.
  •  
5.
  • Y Banaem, Hossein, et al. (författare)
  • Brain tumor modeling : glioma growth and interaction with chemotherapy
  • 2011
  • Ingår i: International Conference on Graphic and Image Processing (ICGIP 2011). - : SPIE. ; 8285
  • Konferensbidrag (refereegranskat)abstract
    • In last decade increasingly mathematical models of tumor growths have been studied, particularly on solid tumors which growth mainly caused by cellular proliferation. In this paper we propose a modified model to simulate the growth of gliomas in different stages. Glioma growth is modeled by a reaction-advection-diffusion. We begin with a model of untreated gliomas and continue with models of polyclonal glioma following chemotherapy. From relatively simple assumptions involving homogeneous brain tissue bounded by a few gross anatomical landmarks (ventricles and skull) the models have been expanded to include heterogeneous brain tissue with different motilities of glioma cells in grey and white matter. Tumor growth is characterized by a dangerous change in the control mechanisms, which normally maintain a balance between the rate of proliferation and the rate of apoptosis (controlled cell death). Result shows that this model closes to clinical finding and can simulate brain tumor behavior properly.
  •  
6.
  • Borrelli, P., et al. (författare)
  • Artificial intelligence-aided CT segmentation for body composition analysis: a validation study
  • 2021
  • Ingår i: European Radiology Experimental. - : Springer Science and Business Media LLC. - 2509-9280. ; 5:1
  • Tidskriftsartikel (refereegranskat)abstract
    • BackgroundBody composition is associated with survival outcome in oncological patients, but it is not routinely calculated. Manual segmentation of subcutaneous adipose tissue (SAT) and muscle is time-consuming and therefore limited to a single CT slice. Our goal was to develop an artificial-intelligence (AI)-based method for automated quantification of three-dimensional SAT and muscle volumes from CT images.MethodsEthical approvals from Gothenburg and Lund Universities were obtained. Convolutional neural networks were trained to segment SAT and muscle using manual segmentations on CT images from a training group of 50 patients. The method was applied to a separate test group of 74 cancer patients, who had two CT studies each with a median interval between the studies of 3days. Manual segmentations in a single CT slice were used for comparison. The accuracy was measured as overlap between the automated and manual segmentations.ResultsThe accuracy of the AI method was 0.96 for SAT and 0.94 for muscle. The average differences in volumes were significantly lower than the corresponding differences in areas in a single CT slice: 1.8% versus 5.0% (p <0.001) for SAT and 1.9% versus 3.9% (p < 0.001) for muscle. The 95% confidence intervals for predicted volumes in an individual subject from the corresponding single CT slice areas were in the order of 20%.Conclusions The AI-based tool for quantification of SAT and muscle volumes showed high accuracy and reproducibility and provided a body composition analysis that is more relevant than manual analysis of a single CT slice.
  •  
7.
  • Broman, Mikael, et al. (författare)
  • Recirculation during veno-venous extra-corporeal membrane oxygenation - a simulation study
  • 2015
  • Ingår i: International Journal of Artificial Organs. - : SAGE Publications. - 0391-3988 .- 1724-6040. ; 38:1, s. 23-30
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: Veno-venous ECMO is indicated in reversible life-threatening respiratory failure without life-threatening circulatory failure. Recirculation of oxygenated blood in the ECMO circuit decreases efficiency of patient oxygen delivery but is difficult to measure. We seek to identify and quantify some of the factors responsible for recirculation in a simulation model and compare with clinical data. Methods: A closed-loop real-time simulation model of the cardiovascular system has been developed. ECMO is simulated with a fixed flow pump 0 to 5 l/min with various cannulation sites -1) right atrium to inferior vena cava, 2) inferior vena cava to right atrium, and 3) superior+ inferior vena cava to right atrium. Simulations are compared to data from a retrospective cohort of 11 consecutive adult veno-venous ECMO patients in our department. Results: Recirculation increases with increasing ECMO-flow, decreases with increasing cardiac output, and is highly dependent on choice of cannulation sites. A more peripheral drainage site decreases recirculation substantially. Conclusions: Simulations suggest that recirculation is a significant clinical problem in veno-venous ECMO in agreement with clinical data. Due to the difficulties in measuring recirculation and interpretation of the venous oxygen saturation in the ECMO drainage blood, flow settings and cannula positioning should rather be optimized with help of arterial oxygenation parameters. Simulation may be useful in quantification and understanding of recirculation in VV-ECMO.
  •  
8.
  • Cervin, Ida, et al. (författare)
  • Improving the creation and reporting of structured findings during digital pathology review
  • 2016
  • Ingår i: Journal of Pathology Informatics. - : Medknow Publications. - 2229-5089 .- 2153-3539. ; 7:1, s. 32-32
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Today, pathology reporting consists of many separate tasks, carried out by multiple people. Common tasks include dictation during case review, transcription, verification of the transcription, report distribution, and report the key findings to follow-up registries. Introduction of digital workstations makes it possible to remove some of these tasks and simplify others. This study describes the work presented at the Nordic Symposium on Digital Pathology 2015, in Linköping, Sweden. Methods: We explored the possibility to have a digital tool that simplifies image review by assisting note-taking, and with minimal extra effort, populates a structured report. Thus, our prototype sees reporting as an activity interleaved with image review rather than a separate final step. We created an interface to collect, sort, and display findings for the most common reporting needs, such as tumor size, grading, and scoring. Results: The interface was designed to reduce the need to retain partial findings in the head or on paper, while at the same time be structured enough to support automatic extraction of key findings for follow-up registry reporting. The final prototype was evaluated with two pathologists, diagnosing complicated partial mastectomy cases. The pathologists experienced that the prototype aided them during the review and that it created a better overall workflow. Conclusions: These results show that it is feasible to simplify the reporting tasks in a way that is not distracting, while at the same time being able to automatically extract the key findings. This simplification is possible due to the realization that the structured format needed for automatic extraction of data can be used to offload the pathologists' working memory during the diagnostic review.
  •  
9.
  • Grönlund, Christer, et al. (författare)
  • Imaging two-dimensional mechanical waves of skeletal muscle contraction
  • 2013
  • Ingår i: Ultrasound in Medicine and Biology. - : Elsevier BV. - 0301-5629 .- 1879-291X. ; 39:2, s. 360-369
  • Tidskriftsartikel (refereegranskat)abstract
    • Skeletal muscle contraction is related to rapid mechanical shortening and thickening. Recently, specialized ultrasound systems have been applied to demonstrate and quantify transient tissue velocities and one-dimensional (1-D) propagation of mechanical waves during muscle contraction. Such waves could potentially provide novel information on musculoskeletal characteristics, function and disorders. In this work, we demonstrate two-dimensional (2-D) mechanical wave imaging following the skeletal muscle contraction. B-mode image acquisition during multiple consecutive electrostimulations, speckle-tracking and a time-stamp sorting protocol were used to obtain 1.4 kHz frame rate 2-D tissue velocity imaging of the biceps brachii muscle contraction. The results present novel information on tissue velocity profiles and mechanical wave propagation. In particular, counter-propagating compressional and shear waves in the longitudinal direction were observed in the contracting tissue (speed 2.8-4.4 m/s) and a compressional wave in the transverse direction of the non-contracting muscle tissue (1.2-1.9 m/s). In conclusion, analysing transient 2-D tissue velocity allows simultaneous assessment of both active and passive muscle tissue properties. (E-mail: christer.gronlund@vll.se) (C) 2013 World Federation for Ultrasound in Medicine & Biology.
  •  
10.
  • Mendrik, AM, et al. (författare)
  • MRBrainS Challenge: Online Evaluation Framework for Brain Image Segmentation in 3T MRI Scans
  • 2015
  • Ingår i: Computational Intelligence and Neuroscience. - : Hindawi Publishing Corporation. - 1687-5265 .- 1687-5273. ; 2015
  • Tidskriftsartikel (refereegranskat)abstract
    • Many methods have been proposed for tissue segmentation in brain MRI scans. The multitude of methods proposed complicates the choice of one method above others. We have therefore established the MRBrainS online evaluation framework for evaluating (semi)automatic algorithms that segment gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF) on 3T brain MRI scans of elderly subjects (65–80 y). Participants apply their algorithms to the provided data, after which their results are evaluated and ranked. Full manual segmentations of GM, WM, and CSF are available for all scans and used as the reference standard. Five datasets are provided for training and fifteen for testing. The evaluated methods are ranked based on their overall performance to segment GM, WM, and CSF and evaluated using three evaluation metrics (Dice, H95, and AVD) and the results are published on the MRBrainS13 website. We present the results of eleven segmentation algorithms that participated in the MRBrainS13 challenge workshop at MICCAI, where the framework was launched, and three commonly used freeware packages: FreeSurfer, FSL, and SPM. The MRBrainS evaluation framework provides an objective and direct comparison of all evaluated algorithms and can aid in selecting the best performing method for the segmentation goal at hand.
  •  
11.
  • Nilsson, Daniel, et al. (författare)
  • Patient-specific brain arteries molded as a flexible phantom model using 3D printed water-soluble resin
  • 2022
  • Ingår i: Scientific Reports. - : Nature Publishing Group. - 2045-2322. ; 12
  • Tidskriftsartikel (refereegranskat)abstract
    • Visualizing medical images from patients as physical 3D models (phantom models) have many roles in the medical field, from education to preclinical preparation and clinical research. However, current phantom models are generally generic, expensive, and time-consuming to fabricate. Thus, there is a need for a cost- and time-efficient pipeline from medical imaging to patient-specific phantom models. In this work, we present a method for creating complex 3D sacrificial molds using an off-the-shelf water-soluble resin and a low-cost desktop 3D printer. This enables us to recreate parts of the cerebral arterial tree as a full-scale phantom model (10×6×410×6×4 cm) in transparent silicone rubber (polydimethylsiloxane, PDMS) from computed tomography angiography images (CTA). We analyzed the model with magnetic resonance imaging (MRI) and compared it with the patient data. The results show good agreement and smooth surfaces for the arteries. We also evaluate our method by looking at its capability to reproduce 1 mm channels and sharp corners. We found that round shapes are well reproduced, whereas sharp features show some divergence. Our method can fabricate a patient-specific phantom model with less than 2 h of total labor time and at a low fabrication cost.
  •  
12.
  • Sabernaeemi, Amir, et al. (författare)
  • Influence of stent-induced vessel deformation on hemodynamic feature of bloodstream inside ICA aneurysms
  • 2023
  • Ingår i: Biomechanics and Modeling in Mechanobiology. - : Springer Science and Business Media LLC. - 1617-7959 .- 1617-7940. ; 22:4, s. 1193-1207
  • Tidskriftsartikel (refereegranskat)abstract
    • One of the effective treatment options for intracranial aneurysms is stent-assisted coiling. Though, previous works have demonstrated that stent usage would result in the deformation of the local vasculature. The effect of simple stent on the blood hemodynamics is still uncertain. In this work, hemodynamic features of the blood stream on four different ICA aneurysm with/without interventional are investigated. To estimate the relative impacts of vessel deformation, four distinctive ICA aneurysm is simulated by the one-way FSI technique. Four hemodynamic factors of aneurysm blood velocity, wall pressure and WSS are compared in the peak systolic stage to disclose the impact of defamation by the stent in two conditions. The stent usage would decrease almost all of the mentioned parameters, except for OSI. Stenting reduces neck inflow rate, while the effect of interventional was not consistent among the aneurysms. The deformation of an aneurysm has a strong influence on the hemodynamics of an aneurysm. This outcome is ignored by most of the preceding investigations, which focused on the pre-interventional state for studying the relationship between hemodynamics and stents. Present results show that the application of stent without coiling would improve most hemodynamic factors, especially when the deformation of the aneurysm is high enough.
  •  
13.
  • Tampu, Iulian Emil, et al. (författare)
  • Deep-learning for thyroid microstructure segmentation in 2D OCT images
  • 2021
  • Ingår i: Optical Coherence Tomography and Coherence Domain Optical Methods in Biomedicine XXV. - : SPIE - International Society for Optical Engineering.
  • Konferensbidrag (refereegranskat)abstract
    • Optical coherence tomography (OCT) can provide exquisite details of tissue microstructure without traditional tissue sectioning, with potential diagnostic and intraoperative applications in a variety of clinical areas. In thyroid surgery, OCT could provide information to reduce the risk of damaging normal tissue. Thyroid tissue's follicular structure alters in case of various pathologies including the non-malignant ones which can be imaged using OCT. The success of deep learning for medical image analysis encourages its application on OCT thyroid images for quantitative analysis of tissue microstructure. To investigate the potential of a deep learning approach to segment the follicular structure in OCT images, a 2D U-Net was trained on b-scan OCT images acquired from ex vivo adult human thyroid samples a effected by a range of pathologies. Results on a pool of 104 annotated images showed a mean Dice score of 0.74±0.19 and 0.92±0.09 when segmenting the follicular structure and the surrounding tissue on the test dataset (n=10 images). This study shows that a deep learning approach for tissue microstructure segmentation in OCT images is possible. The achieved performance without requiring manual intervention encourages the application of a deep-learning method for real-time analysis of OCT data.
  •  
14.
  • Yousefi, Hossein, et al. (författare)
  • An optimised linear mechanical model for estimating brain shift caused by meningioma tumours
  • 2013
  • Ingår i: International Journal of Biomedical Science and Engineering. - : Science Publishing Group. - 2376-7227 .- 2376-7235. ; 1:1, s. 1-9
  • Tidskriftsartikel (refereegranskat)abstract
    • Estimation of brain deformation plays an important role in computer-aided therapy and image-guided neurosurgery systems. Tumour growth can cause brain deformation and change stress distribution in the brain. Biomechanical models exist that use a finite element method to estimate brain shift caused by tumour growth. Such models can be categorised as linear and non-linear models, both of which assume finite deformation of the brain after tumour growth. Linear models are easy to implement and fast enough to for applications such as IGS where the time is a great of concern. However their accuracy highly dependent on the parameters of the models in this paper, we proposed an optimisation approach to improve a naive linear model to achieve more precise estimation of brain displacements caused by tumour growth. The optimisation process has improved the accuracy of the model by adapting the brain model parameters according to different tomour sizes.We used patient-based tetrahedron finite element mesh with proper material properties for brain tissue and appropriate boundary conditions in the tumour region. Anatomical landmarks were determined by an expert and were divided into two different sets for evaluation and optimisation. Tetrahedral finite element meshes were used and the model parameters were optimised by minimising the mean square distance between the predicted locations of the anatomical landmarks derived from Brain Atlas images and their actual locations on the tumour images. Our results demonstrate great improvement in the accuracy of an optimised linear mechanical model that achieved an accuracy rate of approximately 92%.
  •  
15.
  • Fredén Jansson, Karl-Johan, 1988 (författare)
  • The Balanced Electromagnetic Separation Transducer for Bone Conduction Audiometry and Hearing Rehabilitation
  • 2017
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Hearing via air conduction (AC) and bone conduction (BC) are attributed to bethe natural ways of conducting sound to the cochlea. With AC hearing, air pressurevariations are transmitted to the cochlea via the ear canal, whereas with BChearing, sound vibrations are transmitted through the skull bone to the cochlea.Patients with a hearing loss in the cochlea or auditory nerve are commonly rehabilitatedwith conventional AC hearing aids in the ear canal, but also using cochlearimplants. If the pathway for AC sound to reach the cochlea is obstructed, patientscan often benet from bone conduction devices (BCDs). In order to determinethe type and degree of hearing loss, the BC hearing thresholds are measured usinga bone conduction vibrator, and then analyzed together with the AC hearingthresholds for the diagnosis and to suggest an appropriate rehabilitation alternative.The motor unit in conventional BCDs and bone vibrators are known togenerate high amount of distortion at low frequencies where the Balanced ElectromagneticSeparation Transducer (BEST) principle may oer a new era in BChearing rehabilitation and audiometry.This thesis combines two BC hearing related topics, where the rst topic is anevaluation of a new audiometric bone vibrator, Radioear B81, which is assumedto oer more accurate BC hearing threshold measurements. The second topic isrelated to a new type of active transcutaneous BCD, called the Bone ConductionImplant (BCI), which leaves the skin intact by using a wireless solution thatdoes not require a permanent skin penetration. Even though the applications aredierent, both devices use the BEST principle as motor unit in their design.The audiometric bone vibrator Radioear B81 was found to have an improvedperformance at low frequencies where it can produce higher output levels with lessharmonic distortion than the conventional Radioear B71. In a clinical study of therst six patients, the BCI was found as ecient as already commercially availableBCDs, and with the advantage of not needing a skin penetration. In a technicalevaluation of the BCI, it was shown to be a mechanically robust design and totolerate magnetic resonance imaging at 1.5 Tesla.
  •  
16.
  • Grishenkov, Dmitry, 1983-, et al. (författare)
  • In search of the optimal ultrasound heart perfusion imaging platform
  • 2015
  • Ingår i: Journal of ultrasound in medicine. - : Wiley. - 0278-4297 .- 1550-9613. ; 34:9, s. 1599-1605
  • Tidskriftsartikel (refereegranskat)abstract
    • ObjectiveQuantification of the myocardial perfusion by contrast echocardiography (CEC) remains a challenge. Existing imaging phantoms used to evaluate the performance of ultrasound scanners do not comply with perfusion basics in the myocardium, where perfusion and motion are inherently coupled.MethodsTo contribute towards an improvement, we developed a CEC perfusion imaging platform based on isolated rat heart coupled to the ultrasound scanner. Perfusion was assessed using three different types of contrast agent: dextran-based Promiten®, phospholipid-shelled SonoVue®, and polymer-shelled MB-pH5-RT. The myocardial video-intensity was monitored over time from contrast administration to peak and two characteristic constants were calculated using exponential fit (A representing capillary volume and b representing inflow velocity).ResultsAcquired experimental evidence demonstrates that the application of all three types of contrast agent allow ultrasonic estimation of myocardial perfusion in the isolated rat heart. Video-intensity maps show that an increase in contrast concentration increases the late plateau values, A, mimicking increased capillary volume. Estimated values of the flow, proportional to Axb, increase when the pressure of the perfusate column increases from 80 to 110 cm of water. This finding is in agreement with the true values of the coronary flow increase measured by the flowmeter attached to the aortic cannula.ConclusionsThe described CEC perfusion imaging platform holds promise for standardized evaluation and optimization of ultrasound contrast perfusion imaging where real time inflow curves at low acoustic power semi-quantitatively reflect coronary flow.
  •  
17.
  • Isaksson-Daun, Johan (författare)
  • A Sound Approach Toward a Mobility Aid for Blind and Low-Vision Individuals
  • 2023
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Reduced independent mobility of blind and low-vision individuals (BLVIs) cause considerable societal cost, burden on relatives, and reduced quality of life for the individuals, including increased anxiety, depression symptoms, need of assistance, risk of falls, and mortality. Despite the numerous electronic travel aids proposed since at least the 1940’s, along with ever-advancing technology, the mobility issues persist. A substantial reason for this is likely several and severe shortcomings of the field, both in regards to aid design and evaluation.In this work, these shortcomings are addressed with a generic design model called Desire of Use (DoU), which describes the desire of a given user to use an aid for a given activity. It is then applied on mobility of BLVIs (DoU-MoB), to systematically illuminate and structure possibly all related aspects that such an aid needs to aptly deal with, in order for it to become an adequate aid for the objective. These aspects can then both guide user-centered design as well as choice of test methods and measures.One such measure is then demonstrated in the Desire of Use Questionnaire for Mobility of Blind and Low-Vision Individuals (DoUQ-MoB), an aid-agnostic and comprehensive patient-reported outcome measure. The question construction originates from the DoU-MoB to ensure an encompassing focus on mobility of BLVIs, something that has been missing in the field. Since it is aid-agnostic it facilitates aid comparison, which it also actively promotes. To support the reliability of the DoUQ-MoB, it utilizes the best known practices of questionnaire design and has been validated once with eight orientation and mobility professionals, and six BLVIs. Based on this, the questionnaire has also been revised once.To allow for relevant and reproducible methodology, another tool presented herein is a portable virtual reality (VR) system called the Parrot-VR. It uses a hybrid control scheme of absolute rotation by tracking the user’s head in reality, affording intuitive turning; and relative movement where simple button presses on a controller moves the virtual avatar forward and backward, allowing for large-scale traversal while not walking physically. VR provides excellent reproducibility, making various aggregate movement analysis feasible, while it is also inherently safe. Meanwhile, the portability of the system facilitates testing near the participants, substantially increasing the number of potential blind and low-vision recruits for user tests.The thesis also gives a short account on the state of long-term testing in the field; it being short is mainly due to that there is not much to report. It then provides an initial investigation into possible outcome measures for such tests by taking instruments in use by Swedish orientation and mobility professionals as a starting point. Two of these are also piloted in an initial single-session trial with 19 BLVIs, and could plausibly be used for long-term tests after further evaluation.Finally, a discussion is presented regarding the Audomni project — the development of a primary mobility aid for BLVIs. Audomni is a visuo-auditory sensory supplementation device, which aims to take visual information and translate it to sound. A wide field-of-view, 3D-depth camera records the environment, which is then transformed to audio through the sonification algorithms of Audomni, and finally presented in a pair of open-ear headphones that do not block out environmental sounds. The design of Audomni leverages the DoU-MoB to ensure user-centric development and evaluation, in the aim of reaching an aid with such form and function that it grants the users better mobility, while the users still want to use it.Audomni has been evaluated with user tests twice, once in pilot tests with two BLVIs, and once in VR with a heterogenous set of 19 BLVIs, utilizing the Parrot-VR and the DoUQ-MoB. 76 % of responders (13 / 17) answered that it was very or extremely likely that they would want use Audomni along with their current aid. This might be the first result in the field demonstrating a majority of blind and low-vision participants reporting that they actually want to use a new electronic travel aid. This shows promise that eventual long-term tests will demonstrate an increased mobility of blind and low-vision users — the overarching project aim. Such results would ultimately mean that Audomni can become an aid that alleviates societal cost, reduces burden on relatives, and improves users’ quality of life and independence.
  •  
18.
  • Khodadad, Davood, 1985-, et al. (författare)
  • The Value of Phase Angle in Electrical Impedance Tomography Breath Detection
  • 2018
  • Ingår i: 2018 Progress in Electromagnetics Research Symposium (PIERS-Toyama). - : Electromagnetics Academy. - 9784885523168 - 9781538654552 ; , s. 1040-1043
  • Konferensbidrag (refereegranskat)abstract
    • The objective of this paper is to report our investigation demonstrating that the phase angle information of complex impedance could be a simple indicator of a breath cycle in chest Electrical Impedance Tomography (EIT). The study used clinical neonatal EIT data. The results show that measurement of the phase angle from complex EIT data can be used as a complementary information for improving the conventional breath detection algorithms.
  •  
19.
  • Kothapalli, Veera Venkata Satya Naray, 1985-, et al. (författare)
  • Unique pumping-out fracturing mechanism of a polymer-shelled contrast agent : An acoustic characterization and optical visualization
  • 2014
  • Ingår i: IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control. - 0885-3010 .- 1525-8955. ; 62:3, s. 451-462
  • Tidskriftsartikel (refereegranskat)abstract
    • This work describes the fracturing mechanism of air-filled microbubbles (MBs) encapsulated by a cross-linked poly(vinyl alcohol) (PVA) shell. The radial oscillation and fracturing events following the ultrasound exposure were visualized with an ultrahigh-speed camera, and backscattered timedomain signals were acquired with the acoustic setup specific for harmonic detection. No evidence of gas emerging from defects in the shell with the arrival of the first insonation burst was found. In optical recordings, more than one shell defect was noted, and the gas core was drained without any sign of air extrusion when several consecutive bursts of 1 MPa amplitude were applied. In acoustic tests, the backscattered peak-to-peak voltage gradually reached its maximum and exponentially decreased when the PVA-based MB suspension was exposed to approximately 20 consecutive bursts arriving at pulse repetition frequencies of 100 and 500 Hz. Taking into account that the PVA shell is porous and possibly contains large air pockets between the cross-linked PVA chains, the aforementioned acoustic behavior might be attributed to pumping gas from these pockets in combination with gas release from the core through shell defects. We refer to this fracturing mechanism as pumping-out behavior, and this behavior could have potential use for the local delivery of therapeutic gases, such as nitric oxide.
  •  
20.
  •  
21.
  • Azar, Jimmy, et al. (författare)
  • Automated Classification of Glandular Tissue by Statistical Proximity Sampling
  • 2015
  • Ingår i: International Journal of Biomedical Imaging. - : Hindawi Limited. - 1687-4188 .- 1687-4196.
  • Tidskriftsartikel (refereegranskat)abstract
    • Due to the complexity of biological tissue and variations in staining procedures, features that are based on the explicit extraction of properties from subglandular structures in tissue images may have difficulty generalizing well over an unrestricted set of images and staining variations. We circumvent this problem by an implicit representation that is both robust and highly descriptive, especially when combined with a multiple instance learning approach to image classification. The new feature method is able to describe tissue architecture based on glandular structure. It is based on statistically representing the relative distribution of tissue components around lumen regions, while preserving spatial and quantitative information, as a basis for diagnosing and analyzing different areas within an image. We demonstrate the efficacy of the method in extracting discriminative features for obtaining high classification rates for tubular formation in both healthy and cancerous tissue, which is an important component in Gleason and tubule-based Elston grading. The proposed method may be used for glandular classification, also in other tissue types, in addition to general applicability as a region-based feature descriptor in image analysis where the image represents a bag with a certain label (or grade) and the region-based feature vectors represent instances.
  •  
22.
  • Ge, Chenjie, 1991, et al. (författare)
  • 3D Multi-Scale Convolutional Networks for Glioma Grading Using MR Images
  • 2018
  • Ingår i: Proceedings - International Conference on Image Processing, ICIP. - 1522-4880. - 9781479970612 ; , s. 141-145
  • Konferensbidrag (refereegranskat)abstract
    • This paper addresses issues of grading brain tumor, glioma, from Magnetic Resonance Images (MRIs). Although feature pyramid is shown to be useful to extract multi-scale features for object recognition, it is rarely explored in MRI images for glioma classification/grading. For glioma grading, existing deep learning methods often use convolutional neural networks (CNNs) to extract single-scale features without considering that the scales of brain tumor features vary depending on structure/shape, size, tissue smoothness, and locations. In this paper, we propose to incorporate the multi-scale feature learning into a deep convolutional network architecture, which extracts multi-scale semantic as well as fine features for glioma tumor grading. The main contributions of the paper are: (a) propose a novel 3D multi-scale convolutional network architecture for the dedicated task of glioma grading; (b) propose a novel feature fusion scheme that further refines multi-scale features generated from multi-scale convolutional layers; (c) propose a saliency-aware strategy to enhance tumor regions of MRIs. Experiments were conducted on an open dataset for classifying high/low grade gliomas. Performance on the test set using the proposed scheme has shown good results (with accuracy of 89.47%).
  •  
23.
  • Ge, Chenjie, 1991, et al. (författare)
  • Multiscale Deep Convolutional Networks for Characterization and Detection of Alzheimer's Disease using MR Images
  • 2019
  • Ingår i: Proceedings - International Conference on Image Processing, ICIP. - 1522-4880. ; 2019-September, s. 789-793
  • Konferensbidrag (refereegranskat)abstract
    • This paper addresses the issues of Alzheimer's disease (AD) characterization and detection from Magnetic Resonance Images (MRIs). Many existing AD detection methods use single-scale feature learning from brain scans. In this paper, we propose a multiscale deep learning architecture for learning AD features. The main contributions of the paper include: (a) propose a novel 3D multiscale CNN architecture for the dedicated task of AD detection; (b) propose a feature fusion and enhancement strategy for multiscale features; (c) empirical study on the impact of several settings, including two dataset partitioning approaches, and the use of multiscale and feature enhancement. Experiments were conducted on an open ADNI dataset (1198 brain scans from 337 subjects), test results have shown the effectiveness of the proposed method with test accuracy of 93.53%, 87.24% (best, average) on subject separated dataset, and 99.44%, 98.80% (best, average) on random brain scan-partitioned dataset. Comparison with eight existing methods has provided further support to the proposed method.
  •  
24.
  • Grönlund, Christer, 1975-, et al. (författare)
  • Significant beat-to-beat variability of E/e’ irrespective of respiration
  • 2013
  • Ingår i: International cardiovascular forum. - : Barcaray Publishing. - 2409-3424 .- 2410-2636. ; 1:2, s. 88-89
  • Tidskriftsartikel (refereegranskat)abstract
    • The E/e’ ratio is commonly used in Doppler echocardiographic examinations to estimate the pulmonary capillary wedge pressure. The rationale of using this ratio is to combine left ventricular (LV) filling (E) and relaxation (e’) velocities to indirectly assess left atrial pressure. However, the accuracy of this index has recently been questioned, particularly in patients with controlled heart failure. Likewise, the potential beat-to-beat variability of such measurements remains undetermined. The cardiovascular system is subject to several oscillations with the potential of influencing LV function and its intra-cavitary pressures, hence measurements of its filling and relaxation velocities. The aim of this pilot study was to assess the beat-to-beat variability of the E/e’ ratio in one minute long examination in healthy subjects, and patients with various severity of amyloid heart disease. The results show that despite critical application of the standard echocardiographic recording recommendations, E/e’ beat-to-beat variability was 36 % (22 to 50%) in healthy subjects and 17 % (11-26%) in patients, and where the most severe amyloid heart disease had the least variability. Thus, clinical use of a single or few cardiac beats might not necessarily reflect an accurate ratio between the two velocities, and hence casts doubt over their diagnostic value.
  •  
25.
  • Hagberg, Eva, et al. (författare)
  • Semi-supervised learning with natural language processing for right ventricle classification in echocardiography—a scalable approach
  • 2022
  • Ingår i: Computers in Biology and Medicine. - : Elsevier BV. - 0010-4825 .- 1879-0534. ; 143
  • Tidskriftsartikel (refereegranskat)abstract
    • We created a deep learning model, trained on text classified by natural language processing (NLP), to assess right ventricular (RV) size and function from echocardiographic images. We included 12,684 examinations with corresponding written reports for text classification. After manual annotation of 1489 reports, we trained an NLP model to classify the remaining 10,651 reports. A view classifier was developed to select the 4-chamber or RV-focused view from an echocardiographic examination (n = 539). The final models were two image classification models trained on the predicted labels from the combined manual annotation and NLP models and the corresponding echocardiographic view to assess RV function (training set n = 11,008) and size (training set n = 9951. The text classifier identified impaired RV function with 99% sensitivity and 98% specificity and RV enlargement with 98% sensitivity and 98% specificity. The view classification model identified the 4-chamber view with 92% accuracy and the RV-focused view with 73% accuracy. The image classification models identified impaired RV function with 93% sensitivity and 72% specificity and an enlarged RV with 80% sensitivity and 85% specificity; agreement with the written reports was substantial (both κ = 0.65). Our findings show that models for automatic image assessment can be trained to classify RV size and function by using model-annotated data from written echocardiography reports. This pipeline for auto-annotation of the echocardiographic images, using a NLP model with medical reports as input, can be used to train an image-assessment model without manual annotation of images and enables fast and inexpensive expansion of the training dataset when needed. © 2022
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-25 av 1733
Typ av publikation
tidskriftsartikel (881)
konferensbidrag (631)
doktorsavhandling (85)
annan publikation (46)
bokkapitel (30)
forskningsöversikt (19)
visa fler...
rapport (16)
licentiatavhandling (12)
patent (10)
proceedings (redaktörskap) (2)
samlingsverk (redaktörskap) (1)
visa färre...
Typ av innehåll
refereegranskat (1356)
övrigt vetenskapligt/konstnärligt (366)
populärvet., debatt m.m. (9)
Författare/redaktör
Lindblad, Joakim (68)
Sladoje, Nataša (62)
Borga, Magnus (51)
Bengtsson, Ewert (45)
Wang, Chunliang, 198 ... (43)
Strand, Robin, 1978- (42)
visa fler...
Enqvist, Olof, 1981 (37)
Moreno, Rodrigo, 197 ... (37)
Smedby, Örjan, Profe ... (36)
Mehnert, Andrew, 196 ... (35)
Knutsson, Hans (34)
Sintorn, Ida-Maria (32)
Smedby, Örjan (31)
Romu, Thobias (31)
Frimmel, Hans (30)
Malmberg, Filip (29)
Helms, Gunther (28)
Wählby, Carolina (28)
Eklund, Anders, 1981 ... (26)
Dahlqvist Leinhard, ... (26)
Yu, Jun, 1962- (26)
Trägårdh, Elin (25)
Ulen, Johannes (25)
Kahl, Fredrik, 1972 (25)
Persson, Mats, 1987- (25)
Båth, Magnus, 1974 (23)
Smedby, Örjan, 1956- (22)
Dahlqvist Leinhard, ... (21)
Kullberg, Joel (21)
Wählby, Carolina, pr ... (21)
Nyström, Ingela (21)
Strand, Robin (20)
Edenbrandt, Lars, 19 ... (20)
Bjällmark, Anna (20)
Andersson, Mats (19)
Ebbers, Tino (19)
Gu, Irene Yu-Hua, 19 ... (18)
Larsson, Matilda (18)
Forsberg, Daniel (18)
Cinthio, Magnus (17)
Gustafsson, Agnetha, ... (17)
Månsson, Lars Gunnar ... (17)
Ahlström, Håkan (16)
Persson, Anders (16)
Ahlström, Håkan, 195 ... (15)
Kullberg, Joel, 1979 ... (14)
Grönlund, Christer (14)
Alvén, Jennifer, 198 ... (14)
Wang, Chunliang (14)
Dyverfeldt, Petter (14)
visa färre...
Lärosäte
Uppsala universitet (448)
Linköpings universitet (412)
Kungliga Tekniska Högskolan (295)
Lunds universitet (258)
Chalmers tekniska högskola (252)
Umeå universitet (128)
visa fler...
Göteborgs universitet (120)
Karolinska Institutet (93)
Sveriges Lantbruksuniversitet (34)
Örebro universitet (27)
Jönköping University (24)
Luleå tekniska universitet (22)
Linnéuniversitetet (19)
Blekinge Tekniska Högskola (14)
Högskolan i Halmstad (12)
Stockholms universitet (11)
RISE (10)
Mittuniversitetet (5)
Högskolan Dalarna (4)
Högskolan Väst (3)
Malmö universitet (3)
Högskolan i Gävle (2)
Mälardalens universitet (2)
Högskolan i Borås (1)
Karlstads universitet (1)
visa färre...
Språk
Engelska (1712)
Svenska (21)
Forskningsämne (UKÄ/SCB)
Teknik (1733)
Medicin och hälsovetenskap (525)
Naturvetenskap (430)
Samhällsvetenskap (9)
Lantbruksvetenskap (6)
Humaniora (3)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy