SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Figueiredo João Paulo) "

Sökning: WFRF:(Figueiredo João Paulo)

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Rainford, Louise, et al. (författare)
  • Education and training in radiation protection in Europe : an analysis from the EURAMED rocc-n-roll project
  • 2022
  • Ingår i: Insights into Imaging. - : Springer. - 1869-4101. ; 13:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: A Strengths, weaknesses, opportunities and threats analysis was performed to understand the status quo of education and training in radiation protection (RP) and to develop a coordinated European approach to RP training needs based on stakeholder consensus and existing activities in the field. Fourteen team members represented six European professional societies, one European voluntary organisation, two international healthcare organisations and five professions, namely: Medical Physicists; Nuclear Medicine Physicians; Radiologists; Radiation Oncologists and Radiographers. Four subgroups analysed the "Strengths", "Weaknesses", "Opportunities" and "Threats" related to E&T in RP developed under previous European Union (EU) programmes and on the Guidelines on Radiation Protection Education and Training of Medical Professionals in the EU.Results: Consensus agreement identified four themes for strengths and opportunities, namely: (1) existing structures and training recommendations; (2) RP training needs assessment and education & training (E&T) model(s) development; (3) E&T dissemination, harmonisation, and accreditation; (4) financial supports. Weaknesses and Threats analysis identified two themes: (1) awareness and prioritisation at a national/global level and (2) awareness and prioritisation by healthcare professional groups and researchers.Conclusions: A lack of effective implementation of RP principles in daily practice was identified. EuRnR strategic planning needs to consider processes at European, national and local levels. Success is dependent upon efficient governance structures and expert leadership. Financial support is required to allow the stakeholder professional agencies to have sufficient resources to achieve a pan European radiation protection training network which is sustainable and accredited across multiple national domains.
  •  
3.
  • Santos, Joana, et al. (författare)
  • Education and training in radiation protection in Europe : results from the EURAMED Rocc-n-Roll project survey
  • 2023
  • Ingår i: Insights into Imaging. - : Springer. - 1869-4101. ; 14:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To analyse the existing radiation protection (RP) education and training (E&T) capabilities in the European Union and identify associated needs, problems and challenges.Method: An online survey was disseminated via the EURAMED Rocc-n-Roll consortium network and prominent medical societies in the field of radiological research. The survey sections analyse the RP E&T during undergraduate, residency/internship and continuous professional development; RP E&T problems and legal implementation. Differences were analysed by European geographic regions, profession, years of professional experience and main area of practice/research.Results: The majority of the 550 respondents indicated that RP topics are part of undergraduate curricula in all courses for their profession and country (55%); however, hands-on practical training is not included according to 30% of the respondents. The lack of E&T, practical aspects in current E&T, and mandatory continuing E&T were considered the major problems. The legal requirement that obtained higher implementation score was the inclusion of the practical aspects of medical radiological procedures on education (86%), and lower score was obtained for the inclusion of RP E&T on medical and dental school curriculums (61%).Conclusions: A heterogeneity in RP E&T during undergraduate, residency/internship and continuous professional development is evident across Europe. Differences were noted per area of practice/research, profession, and European geographic region. A large variation in RP E&T problem rating was also obtained.
  •  
4.
  • Ferreira, Marisa Borges, et al. (författare)
  • Relationships between neuropsychological and antisaccade measures in multiple sclerosis patients
  • 2018
  • Ingår i: PeerJ. - : PeerJ, Inc. - 2167-8359. ; 6, s. 1-18
  • Tidskriftsartikel (refereegranskat)abstract
    • BackgroundThe Stroop test is frequently used to assess deficits in inhibitory control in people with multiple sclerosis (MS). This test has limitations and antisaccade eye movements, that also measure inhibitory control, may be an alternative to Stroop.ObjectivesThe aim of this study was twofold: (i) to investigate if the performance in the antisaccade task is altered in patients with MS and (ii) to investigate the correlation between performances in neuropsychological tests, the Stroop test and the antisaccade task.MethodsWe measured antisaccades (AS) parameters with an infrared eye tracker (SMIRED 250 Hz) using a standard AS paradigm. A total of 38 subjects diagnosed with MS and 38 age and gender matched controls participated in this study. Neuropsychological measures were obtained from the MS group.ResultsPatients with MS have higher error rates and prolonged latency than controls in the antisaccade task. There was a consistent association between the Stroop performance and AS latency. Stroop performance but not AS latency was associated with other neuropsychological measures in which the MS group showed deficits.ConclusionsOur findings suggest that AS may be a selective and independent measure to investigate inhibitory control in patients with MS. More studies are necessary to confirm our results and to describe brain correlates associated with impaired performance in the antisaccade task in people diagnosed with MS.
  •  
5.
  • Macedo, António Filipe, et al. (författare)
  • Anti-saccades in early stages of multiple sclerosis
  • 2015
  • Ingår i: Investigative Ophthalmology and Visual Science. - 0146-0404 .- 1552-5783. ; 56:7
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: Eye movements disability is common finding in multiple sclerosis (MS) but the exact stage at which changes are visible is not clear. The aim of study was to assess if anti-saccade (AS) planning and execution are altered at early stages of the disease.Methods: A total of 48 participants with MS selected by a neurologist (JJC) at Hospital de Braga and 52 controls participated in this study. Inclusion criteria: relapsing-remitting course, EDSS≤3, 1 month or more without MS crisis, and normal or corrected visual acuity. Exclusion criteria (MS and Control): cognitive impairment, traumatic brain injury or stroke. The mean age in the MS group was 37y and 33y in the control group. Eye movements were monitored using a binocular infrared eyetracker running at 250Hz(RED250, SMI Gmb Germany), precision <0.4deg, stimuli were presented in a 22 monitor (Dell P2210). Code for running the experiment and data analysis was written using the Matlab (Mathworks Inc). Participants were seated in a room dim light at 74cm from the monitor and head movements were minimized by a headband. The task was to fixate, after a variable period between steady fixation and the stimulus of 1250ms or 1600ms, participants looked as quickly as possible for the opposite direction where the target (a 30x30mm cross) was presented (anti-saccade movement). Each subject performed 40 trails.Results: The main results were the proportion of the directional errors (wherein the participant voluntarily looked for the wrong side), and latencies for: i) anti-saccades, ii) pro-saccades (movement in the same direction of the stimulus) and iii) correction (reaction time that the participant takes from the error fixation until to start the movement). The mean number of errors was 28%(SD=19) in MS group and 16%(SD=11) in the control group, mean difference 12%, t(74)=3.83, p<.001. Anti-saccades latency was 330msec (SD=61) in the MS group and 294ms(SD=59) in the control group, mean difference 36ms, F(1,98)=10.99, p<.05. The mean of the correction latency value was 178ms(SD=111) in the MS group and 129ms(SD=107) in the control group with a mean difference of 49ms, F(1,98)=6, p<.05. No statistically significant differences were found in accuracy and pro-saccade latency between groups.Conclusions: This study shows that anti-saccades latency and errors are increased at early stages of multiple sclerosis. Anti-saccades might be a sensitive tool to assess functional status in people with this condition.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy