SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Graafsma Heinz) "

Sökning: WFRF:(Graafsma Heinz)

  • Resultat 1-50 av 81
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Allahgholi, A., et al. (författare)
  • AGIPD 1.0 : The high-speed high dynamic range readout ASIC for the adaptive gain integrating pixel detector at the European XFEL
  • 2014
  • Ingår i: 2014 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2014. - : Institute of Electrical and Electronics Engineers (IEEE). - 9781479960972
  • Konferensbidrag (refereegranskat)abstract
    • AGIPD is a hybrid pixel X-ray detector developed by a collaboration between Deutsches Elektronen-Synchrotron (DESY), Paul-Scherrer-Institute (PSI), University of Hamburg and the University of Bonn. The detector is designed to comply with the requirements of the European XFEL. The radiation tolerant Application Specific Integrated Circuit (ASIC) is designed with the following highlights: high dynamic range, spanning from single photon sensitivity up to 104 × 12.4 keV photons, achieved by the use of dynamic gain switching, auto-selecting one of 3 gains of the charge sensitive pre-amplifier. To cope with the unique features of the European XFEL source, image data is stored in 352 analogue memory cells per pixel. The selected gain is stored in the same way and depth, encoded as one of 3 voltage levels. These memories are operated in random-access mode at 4.5MHz frame rate. Data is read out on a row-by-row basis via multiplexers to the DAQ system for digitisation during the 99.4ms gap between the bunch trains of the European XFEL. The AGIPD 1.0 ASIC features 64×64 pixels with a pixel area of 200×200 μm2. It is bump-bonded to a 500 μm thick silicon sensor. The principles of the chip architecture were proven in different experiments and the ASIC characterization was performed with a series of development prototypes. The mechanical concept of the detector system was developed in close contact with the XFEL beamline scientists to ensure a seamless integration into the beamline setup and is currently being manufactured. The first single module system was successfully tested at APS1 the high dynamic range allows imaging of the direct synchrotron beam along with single photon sensitivity and burst imaging of 352 subsequent frames synchronized to the source.
  •  
2.
  • Allahgholi, A., et al. (författare)
  • AGIPD, a high dynamic range fast detector for the European XFEL
  • 2015
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 10:1
  • Tidskriftsartikel (refereegranskat)abstract
    • AGIPD-(Adaptive Gain Integrating Pixel Detector) is a hybrid pixel X-ray detector developed by a collaboration between Deutsches Elektronen-Synchrotron (DESY), Paul-Scherrer-Institut (PSI), University of Hamburg and the University of Bonn. The detector is designed to comply with the requirements of the European XFEL. The radiation tolerant Application Specific Integrated Circuit (ASIC) is designed with the following highlights: high dynamic range, spanning from single photon sensitivity up to 10(4) 12.5keV photons, achieved by the use of the dynamic gain switching technique using 3 possible gains of the charge sensitive preamplifier. In order to store the image data, the ASIC incorporates 352 analog memory cells per pixel, allowing also to store 3 voltage levels corresponding to the selected gain. It is operated in random-access mode at 4.5MHz frame rate. The data acquisition is done during the 99.4ms between the bunch trains. The AGIPD has a pixel area of 200 x 200 m m(2) and a 500 m m thick silicon sensor is used. The architecture principles were proven in different experiments and the ASIC characterization was done with a series of development prototypes. The mechanical concept was developed in the close contact with the XFEL beamline scientists and is now being manufactured. A first single module system was successfully tested at APS.
  •  
3.
  • Allahgholi, A., et al. (författare)
  • AGIPD, the electronics for a high speed X-ray imager at the Eu-XFEL
  • 2014
  • Ingår i: Proceedings of Science. - : Proceedings of Science (PoS).
  • Konferensbidrag (refereegranskat)abstract
    • The AGIPD (Adaptive Gain Integrated Pixel Detector) X-ray imaging camera will be operated at the X-ray Free Electron Laser, Eu-XFEL, under construction in Hamburg, Germany. Key parameters are 1 million 200 μm square pixels, single 12.4 keV photon detection and a dynamic range to 10 000/pixel/image. The developed sensors, ASICs, PCB-electronics and FPGA firmware acquire individual images per bunch at 27 000 bunches/s, packed into 10 bunch-trains/s with a bunch separation of 222 ns. Bunch-trains are handled by 352 analogue storage cells within each pixel of the ASIC and written during the 0.6msec train delivery. Therefore AGIPD can store 3520 images/s from the delivered 27 000 bunches/s. Random addressing provides reusability of each cell after an image has been declared as low-quality, so that good images can be selected. Digitization is performed between trains (99.4 msec). In the paper all functional blocks are introduced. The details concentrate on the DAQ-chain PCB-electronics and the slow control. A dense area of 1024 ADC-channels, each with a pickup-noise filtering and sampling of up to 50 MS/s/ADC and a serial output of 700 Mbit/s/ADC. FPGAs operate the ASICs synchronized to the bunch structure and collect the bit streams from 64 ADCs/FPGA. Pre-sorted data is transmitted on 10 GbE links out of the camera head using the time between trains. The control and monitoring of the camera with 600 A current consumption is based on a micro-controller and I2C bus with an addressing architecture allowing many devices and identical modules. The high currents require planned return paths at the system level. First experimental experience with the constructed components will be presented.
  •  
4.
  • Allahgholi, A., et al. (författare)
  • Front end ASIC for AGIPD, a high dynamic range fast detector for the European XFEL
  • 2016
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 11:1
  • Tidskriftsartikel (refereegranskat)abstract
    • The Adaptive Gain Integrating Pixel Detector (AGIPD) is a hybrid pixel X-ray detector for the European-XFEL. One of the detector's important parts is the radiation tolerant front end ASIC fulfilling the European-XFEL requirements: high dynamic range-from sensitivity to single 12.5keV-photons up to 104 photons. It is implemented using the dynamic gain switching technique with three possible gains of the charge sensitive preamplifier. Each pixel can store up to 352 images in memory operated in random-access mode at >= 4.5MHz frame rate. An external vetoing may be applied to overwrite unwanted frames.
  •  
5.
  • Allahgholi, Aschkan, et al. (författare)
  • Megapixels @ Megahertz – The AGIPD high-speed cameras for the European XFEL
  • 2019
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 942
  • Forskningsöversikt (refereegranskat)abstract
    • The European XFEL is an extremely brilliant Free Electron Laser Source with a very demanding pulse structure: trains of 2700 X-ray pulses are repeated at 10Hz. The pulses inside the train are spaced by 220ns and each one contains up to 1012photons of 12.4keV, while being ≤100fs in length. AGIPD, the Adaptive Gain Integrating Pixel Detector, is a hybrid pixel detector developed by DESY, PSI, and the Universities of Bonn and Hamburg to cope with these properties. It is a fast, low noise integrating detector, with single photon sensitivity (for Eγ⪆6keV) and a large dynamic range, up to 104 photons at 12.4keV. This is achieved with a charge sensitive amplifier with 3 adaptively selected gains per pixel. 352 images can be recorded at up to 6.5MHz and stored in the in-pixel analogue memory and read out between pulse trains. The core component of this detector is the AGIPD ASIC, which consists of 64 × 64 pixels of 200µm×200µm. Control of the ASIC's image acquisition and analogue readout is via a command based interface. FPGA based electronic boards, controlling ASIC operation, image digitisation and 10GE data transmission interface AGIPD detectors to DAQ and control systems. An AGIPD 1Mpixel detector has been installed at the SPB1 experimental station in August 2017, while a second one is currently commissioned for the MID 2 endstation. A larger (4Mpixel) AGIPD detector and one to employ Hi-Z sensor material to efficiently register photons up to Eγ≈25keV are currently under construction. 
  •  
6.
  • Allahgholi, A., et al. (författare)
  • The adaptive gain integrating pixel detector
  • 2016
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 11:2
  • Tidskriftsartikel (refereegranskat)abstract
    • The adaptive gain integrating pixel detector (AGIPD) is a development of a collaboration between Deustsches Elektronen-Synchrotron (DESY), the Paul-Scherrer-Institute (PSI), the University of Hamburg and the University of Bonn. The detector is designed to cope with the demanding challenges of the European XFEL. Therefore it comes along with an adaptive gain stage allowing a high dynamic range, spanning from single photon sensitivity to 10(4) x 12.4 keV photons and 352 analogue memory cells per pixel. The aim of this report is to briefly explain the concepts of the AGIPD electronics and mechanics and then present recent experiments demonstrating the functionality of its key features.
  •  
7.
  • Allahgholi, Aschkan, et al. (författare)
  • The Adaptive Gain Integrating Pixel Detector at the European XFEL
  • 2019
  • Ingår i: Journal of Synchrotron Radiation. - 0909-0495 .- 1600-5775. ; 26, s. 74-82
  • Tidskriftsartikel (refereegranskat)abstract
    • The Adaptive Gain Integrating Pixel Detector (AGIPD) is an X-ray imager, custom designed for the European X-ray Free-Electron Laser (XFEL). It is a fast, low-noise integrating detector, with an adaptive gain amplifier per pixel. This has an equivalent noise of less than 1keV when detecting single photons and, when switched into another gain state, a dynamic range of more than 10(4)photons of 12keV. In burst mode the system is able to store 352 images while running at up to 6.5MHz, which is compatible with the 4.5MHz frame rate at the European XFEL. The AGIPD system was installed and commissioned in August 2017, and successfully used for the first experiments at the Single Particles, Clusters and Biomolecules (SPB) experimental station at the European XFEL since September 2017. This paper describes the principal components and performance parameters of the system.
  •  
8.
  • Allahgholi, A., et al. (författare)
  • The AGIPD 1.0 ASIC : Random access high frame rate, high dynamic range X-ray camera readout for the European XFEL
  • 2015
  • Ingår i: 2015 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2015. - : Institute of Electrical and Electronics Engineers (IEEE). - 9781467398626
  • Konferensbidrag (refereegranskat)abstract
    • The European XFEL is an extremely brilliant Free Electron Laser Source with a very demanding pulse structure: trains of 2700 X-Ray pulses are repeated at 10 Hz. The pulses inside the train are spaced by 220 ns and each one contains up to 1012 photons of 12.4 keV, while being ≤ 100 fs in length. AGIPD (Adaptive Gain Integrating Pixel Detector) is a hybrid 1M-pixel detector developed by DESY, PSI, and the Universities of Bonn and Hamburg to cope with these properties. Thus the readout ASIC has to provide not only single photon sensitivity and a dynamic range ≳ 104 photons/pixel in the same image but also a memory for as many images of a pulse train as possible for delayed readout prior to the next train. The AGIPD 1.0 ASIC uses a 130 nm CMOS technology and radiation tolerant techniques to withstand the radiation damage incurred by the high impinging photon flux. Each ASIC contains 64 × 64 pixels of 200μmχ200μm. The circuit of each pixel contains a charge sensitive preamplifier with threefold switchable gain, a discriminator for an adaptive gain selection, and a correlated double sampling (CDS) stage to remove reset and low-frequency noise components. The output of the CDS, as well as the dynamically selected gain is sampled in a capacitor-based analogue memory for 352 samples, which occupies about 80% of a pixels area. For readout each pixel features a charge sensitive buffer. A control circuit with a command based interface provides random access to the memory and controls the row-wise readout of the data via multiplexers to four differential analogue ports. The AGIPD 1.0 full scale ASIC has been received back from the foundry in fall of 2013. Since then it has been extensively characterised also with a sensor as a single chip and in 2 × 8-chip modules for the AGIPD 1 Mpix detector. We present the design of the AGIPD 1.0 ASIC along with supporting results, also from beam tests at PETRA III and APS, and show changes incorporated in the recently taped out AGIPD 1.1 ASIC upgrade.
  •  
9.
  • Aquila, Andrew, et al. (författare)
  • Time-resolved protein nanocrystallography using an X-ray free-electron laser
  • 2012
  • Ingår i: Optics Express. - 1094-4087. ; 20:3, s. 2706-2716
  • Tidskriftsartikel (refereegranskat)abstract
    • We demonstrate the use of an X-ray free electron laser synchronized with an optical pump laser to obtain X-ray diffraction snapshots from the photoactivated states of large membrane protein complexes in the form of nanocrystals flowing in a liquid jet. Light-induced changes of Photosystem I-Ferredoxin co-crystals were observed at time delays of 5 to 10 µs after excitation. The result correlates with the microsecond kinetics of electron transfer from Photosystem I to ferredoxin. The undocking process that follows the electron transfer leads to large rearrangements in the crystals that will terminally lead to the disintegration of the crystals. We describe the experimental setup and obtain the first time-resolved femtosecond serial X-ray crystallography results from an irreversible photo-chemical reaction at the Linac Coherent Light Source. This technique opens the door to time-resolved structural studies of reaction dynamics in biological systems.
  •  
10.
  • Assoufid, Lahsen, et al. (författare)
  • Next-generation materials for future synchrotron and free-electron laser sources
  • 2017
  • Ingår i: MRS bulletin. - : Cambridge University Press. - 0883-7694 .- 1938-1425. ; 42:6, s. 418-423
  • Tidskriftsartikel (refereegranskat)abstract
    • The development of new materials and improvements of existing ones are at the root of the spectacular recent developments of new technologies for synchrotron storage rings and free-electron laser sources. This holds true for all relevant application areas, from electron guns to undulators, x-ray optics, and detectors. As demand grows for more powerful and efficient light sources, efficient optics, and high-speed detectors, an overview of ongoing materials research for these applications is timely. In this article, we focus on the most exciting and demanding areas of materials research and development for synchrotron radiation optics and detectors. Materials issues of components for synchrotron and free-electron laser accelerators are briefly discussed. The articles in this issue expand on these topics.
  •  
11.
  • Battaglia, Marco, et al. (författare)
  • R&D paths of pixel detectors for vertex tracking and radiation imaging
  • 2013
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 716, s. 29-45
  • Forskningsöversikt (refereegranskat)abstract
    • This report reviews current trends in the R&D of semiconductor pixellated sensors for vertex tracking and radiation imaging. It identifies requirements of future HEP experiments at colliders, needed technological breakthroughs and highlights the relation to radiation detection and imaging applications in other fields of science.
  •  
12.
  • Becker, J., et al. (författare)
  • Architecture and design of the AGIPD detector for the European XFEL
  • 2012
  • Konferensbidrag (refereegranskat)abstract
    • AGIPD is a hybrid pixel detector developed by DESY, PSI, the University of Bonn and the University of Hamburg. The detector is targeted for use at the European XFEL, a source with unique properties: a bunch train of 2700 pulses with > 1012 photons of 12 keV each, only 100 fs long and with a 220 ns spacing, is repeated at a 10Hz rate. This puts up very demanding requirements: dynamic range has to cover the detection of single photons and extend up to > 104 photons/pixel in the same image, and as many images, as possible have to be recorded in the pixel to be read out between pulse trains. The high photon flux impinging on the detector also calls for a very radiation hard design of sensor and ASIC. The detector will consist of 16 Sensor modules arranged around a central hole for the direct beam. Each made of a single sensor bump-bonded to 2 × 8 readout chips of 64 × 64 pixels in a grid of 200 μm pitch. Each pixel of these ASICs contains a charge sensitive preamplifier featuring adaptive gain switching, changing sensitivity in three ranges, and a buffer to provide correlated double sampling (in the highest sensitivity mode). Most of the pixel area, albeit, is used for an analogue memory to record 352 frames. It is operated in random-access mode: data containing bad frames can be overwritten and the memory can be used in the most efficient way. The readout between two bunch trains is arranged via 4 ports: Data from pixels of one row is read in parallel and serialised by 4 multiplexers at the end of the pixel columns and driven off-chip as differential signals. The operation of the ASIC is controlled via a three-line serial interface, using a command based protocol. It is also used to configure the chip's operational parameters and internal timings. © 2012 IEEE.
  •  
13.
  • Becker, J., et al. (författare)
  • High speed cameras for X-rays : AGIPD and others
  • 2013
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 8:1, s. Art. no. C01042-
  • Tidskriftsartikel (refereegranskat)abstract
    • Experiments at high pulse rate Free Electron Laser (FEL) facilities require new cameras capable of acquiring 2D images at high rates, handling large signal dynamic ranges and resolving images from individual pulses. The Adaptive Gain Integrated Pixel Detector (AGIPD) will operated with pulse rates and separations of 27000/s and 220 ns, respectively at European XFEL. Si-sensors, ASICs, PCBs, and FPGA logic are developed for a 1 Mega-pixel camera with 200 μm square pixels with per-pulse occupancies 104. Data from 3520 images/s will be transferred with 80 Gbits/s to a DAQ-system. The electronics have been adapted for use in other synchrotron light source detectors. 
  •  
14.
  • Becker, J., et al. (författare)
  • Performance tests of an AGIPD 0.4 assembly at the beamline P10 of PETRA III
  • 2013
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 8:6, s. Art. no. P06007-
  • Tidskriftsartikel (refereegranskat)abstract
    • The Adaptive Gain Integrating Pixel Detector (AGIPD) is a novel detector system, currently under development by a collaboration of DESY, the Paul Scherrer Institute in Switzerland, the University of Hamburg and the University of Bonn, and is primarily designed for use at the European XFEL. To verify key features of this detector, an AGIPD 0.4 test chip assembly was tested at the P10 beamline of the PETRA III synchrotron at DESY. The test chip successfully imaged both the direct synchrotron beam and single 7.05 keV photons at the same time, demonstrating the large dynamic range required for XFEL experiments. X-ray scattering measurements from a test sample agree with standard measurements and show the chip's capability of observing dynamics at the microsecond time scale.
  •  
15.
  • Becker, J., et al. (författare)
  • The detector simulation toolkit HORUS
  • 2012
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 7:10, s. Art. no. C10009-
  • Tidskriftsartikel (refereegranskat)abstract
    • In recent years, X-ray detectors used and developed at synchrotron sources and Free Electron Lasers (FELs) have become increasing powerful and versatile. However, as the capabilities of modern X-ray cameras grew so did their complexity and therefore their response functions are far from trivial. Since understanding the detecting system and its behavior is vital for any physical experiment, the need for dedicated powerful simulation tools arose. The HPAD Output Response fUnction Simulator (HORUS) was originally developed to analyze the performance implications of certain design choices for the Adaptive Gain Integrating Pixel Detector (AGIPD) and over the years grew to a more universal detector simulation toolkit covering the relevant physics in the energy range from below 1 keV to a few hundred keV. HORUS has already been used to study possible improvements of the AGIPD for X-ray Photon Correlation Spectroscopy (XPCS) at the European XFEL and its performance at low beam energies. It is currently being used to study the optimum detector layout for Coherent Diffration Imaging (CDI) at the European XFEL. Simulations of the charge summing mode of the Medipix3 chip have been essential for the improvements of the charge summing mode in the Medipix3 RX chip. HORUS is universal enough to support arbitrary hybrid pixel detector systems (within limitations). To date, the following detector systems are predefined within HORUS: The AGIPD, the Large Pixel Detector (LPD), the Cornell-Stanford Pixel Array Detector (CSPAD), the Mixed-Mode (MMPAD) and KEKPAD, and the Medipix2, Medipix3 and Medipix3 RX chips. © 2012 IOP Publishing Ltd and Sissa Medialab srl.
  •  
16.
  • Becker, J., et al. (författare)
  • The high speed, high dynamic range camera AGIPD
  • 2013
  • Ingår i: IEEE Nuclear Science Symposium Conference Record. - : IEEE conference proceedings. - 9781479905348 ; , s. Art. no. 6829504-
  • Konferensbidrag (refereegranskat)abstract
    • The European X-Ray Free Electron Laser (XFEL) will provide ultra short, highly coherent X-ray pulses which will revolutionize scientific experiments in a variety of disciplines spanning physics, chemistry, materials science, and biology. One of the differences between the European XFEL and other free electron laser sources is the high pulse frequency of 4.5 MHz. The European XFEL will provide pulse trains, consisting of up to 2700 pulses separated by 220 ns (600 μs in total) followed by an idle time of 99.4 ms, resulting in a supercycle of 10 Hz. Dedicated fast 2D detectors are being developed, one of which is the Adaptive Gain Integrating Pixel Detector (AGIPD). AGIPD is based on the hybrid pixel technology. The design goals of the recently produced, radiation hard Application Specific Integrated Circuit (ASIC) with dynamic gain switching amplifiers are (for each pixel) a dynamic range of more than 10 4 12.4 keV photons in the lowest gain, single photon sensitivity in the highest gain, an analog memory capable of storing 352 images, and operation at 4.5 MHz frame rate. A vetoing scheme allows to maximize the number of useful images that are acquired by providing the possibility to overwrite any previously recorded image during the pulse train. The AGIPD will feature a pixel size of (200 μm)2 and a silicon sensor with a thickness of 500 μm. The image data is read out and digitized between pulse trains. © 2013 IEEE.
  •  
17.
  • Bianco, L., et al. (författare)
  • The AGIPD System for the European XFEL
  • 2013
  • Ingår i: ADVANCES IN X-RAY FREE-ELECTRON LASERS II. - : SPIE. - 9780819495808 ; , s. Art. no. UNSP 87780V-
  • Konferensbidrag (refereegranskat)abstract
    • The European XFEL will generate extremely brilliant pulses of X-rays organized in pulse trains consisting of 2700 pulses <100 fs long, with >10(12) photons, and with a 220 ns spacing. The pulse trains are running at a 10Hz repetition rate. The detector to be used under these conditions will have to face several challenges: the dynamic range has to cover the detection of single photons and extend up to >10(4) photons/pixel/pulse in the same image, framing rates of 4.5 MHz (220 ns) are required in order to record one image per pulse, and as many images as possible have to be recorded during the pulse trains. Due to the high flux, the detector will have to withstand a dose up to 1GGy integrated over 3 years. To meet these challenges a consortium, consisting of Deutsches Elektronensynchrotron (DESY), Paul-Scherrer-Institut (PSI), University of Hamburg and University of Bonn, is developing the Adaptive Gain Integrating Pixel Detector (AGIPD). It is a hybrid-pixel detector, featuring a charge integrating amplifier with dynamic gain switching to cope with the extended dynamic range, and an analogue on-pixel memory for image storage at the required 4.5 MHz frame rate. The readout chip consists of 64x64 pixels of (200 mu m)(2), 8x2 of these readout chips are bump-bonded to a monolithic silicon sensor to form the basic module with 512 x 128 pixels. 4 of these modules are stacked to form a quadrant of the 1k x 1k detector system. Each quadrant is independently moveable in order to adjust a central hole, needed for the direct beam to pass through. Special designs are employed for both the sensor and the readout chip to withstand the integrated dose for 3 years.
  •  
18.
  • Chapman, Henry N, et al. (författare)
  • Femtosecond X-ray protein nanocrystallography.
  • 2011
  • Ingår i: Nature. - : Springer Science and Business Media LLC. - 1476-4687 .- 0028-0836. ; 470:7332, s. 73-7
  • Tidskriftsartikel (refereegranskat)abstract
    • X-ray crystallography provides the vast majority of macromolecular structures, but the success of the method relies on growing crystals of sufficient size. In conventional measurements, the necessary increase in X-ray dose to record data from crystals that are too small leads to extensive damage before a diffraction signal can be recorded. It is particularly challenging to obtain large, well-diffracting crystals of membrane proteins, for which fewer than 300 unique structures have been determined despite their importance in all living cells. Here we present a method for structure determination where single-crystal X-ray diffraction 'snapshots' are collected from a fully hydrated stream of nanocrystals using femtosecond pulses from a hard-X-ray free-electron laser, the Linac Coherent Light Source. We prove this concept with nanocrystals of photosystem I, one of the largest membrane protein complexes. More than 3,000,000 diffraction patterns were collected in this study, and a three-dimensional data set was assembled from individual photosystem I nanocrystals (∼200nm to 2μm in size). We mitigate the problem of radiation damage in crystallography by using pulses briefer than the timescale of most damage processes. This offers a new approach to structure determination of macromolecules that do not yield crystals of sufficient size for studies using conventional radiation sources or are particularly sensitive to radiation damage.
  •  
19.
  • Correa, J., et al. (författare)
  • Characterisation of a PERCIVAL monolithic active pixel prototype using synchrotron radiation
  • 2016
  • Ingår i: Journal of Instrumentation. - : IOP. - 1748-0221. ; 11:2
  • Tidskriftsartikel (refereegranskat)abstract
    • PERCIVAL ("Pixelated Energy Resolving CMOS Imager, Versatile And Large") is a monolithic active pixel sensor (MAPS) based on CMOS technology. Is being developed by DESY, RAL/STFC, Elettra, DLS, and PAL to address the various requirements of detectors at synchrotron radiation sources and Free Electron Lasers (FELs) in the soft X-ray regime. These requirements include high frame rates and FELs base-rate compatibility, large dynamic range, single-photon counting capability with low probability of false positives, high quantum efficiency (QE), and (multi-)megapixel arrangements with good spatial resolution. Small-scale back-side-illuminated (BSI) prototype systems are undergoing detailed testing with X-rays and optical photons, in preparation of submission of a larger sensor. A first BSI processed prototype was tested in 2014 and a preliminary result—first detection of 350eV photons with some pixel types of PERCIVAL—reported at this meeting a year ago. Subsequent more detailed analysis revealed a very low QE and pointed to contamination as a possible cause. In the past year, BSI-processed chips on two more wafers were tested and their response to soft X-ray evaluated. We report here the improved charge collection efficiency (CCE) of different PERCIVAL pixel types for 400eV soft X-rays together with Airy patterns, response to a flat field, and noise performance for such a newly BSI-processed prototype sensor.
  •  
20.
  • Correa, J., et al. (författare)
  • On the Charge Collection Efficiency of the PERCIVAL Detector
  • 2016
  • Ingår i: Journal of Instrumentation. - : IOP. - 1748-0221. ; 11:12
  • Tidskriftsartikel (refereegranskat)abstract
    • The PERCIVAL soft X-ray imager is being developed by DESY, RAL, Elettra, DLS, and PAL to address the challenges at high brilliance Light Sources such as new-generation Synchrotrons and Free Electron Lasers. Typical requirements for detector systems at these sources are high frame rates, large dynamic range, single-photon counting capability with low probability of false positives, high quantum efficiency, and (multi)-mega-pixel arrangements. PERCIVAL is a monolithic active pixel sensor, based on CMOS technology. It is designed for the soft X-ray regime and, therefore, it is post-processed in order to achieve high quantum efficiency in its primary energy range (250 eV to 1 keV) . This work will report on the latest experimental results on charge collection efficiency obtained for multiple back-side-illuminated test sensors during two campaigns, at the P04 beam-line at PETRA III, and the CiPo beam-line at Elettra, spanning most of the primary energy range as well as testing the performance for photon-energies below 250 eV . In addition, XPS surface analysis was used to cross-check the obtained results.
  •  
21.
  • Correa, J., et al. (författare)
  • The PERCIVAL detector : first user experiments
  • 2023
  • Ingår i: Journal of Synchrotron Radiation. - 0909-0495 .- 1600-5775. ; 30, s. 242-250
  • Tidskriftsartikel (refereegranskat)abstract
    • The PERCIVAL detector is a CMOS imager designed for the soft X-ray regime at photon sources. Although still in its final development phase, it has recently seen its first user experiments: ptychography at a free-electron laser, holographic imaging at a storage ring and preliminary tests on X-ray photon correlation spectroscopy. The detector performed remarkably well in terms of spatial resolution achievable in the sample plane, owing to its small pixel size, large active area and very large dynamic range; but also in terms of its frame rate, which is significantly faster than traditional CCDs. In particular, it is the combination of these features which makes PERCIVAL an attractive option for soft X-ray science.
  •  
22.
  • Correa, J., et al. (författare)
  • The PERCIVAL soft X-ray Detector
  • 2018
  • Ingår i: 2018 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2018 - Proceedings. - : Institute of Electrical and Electronics Engineers (IEEE). - 9781538684948
  • Konferensbidrag (refereegranskat)abstract
    • The PERCIVAL collaboration to develop a soft X-ray imager able to address the challenges of high brilliance light sources, such as new-generation synchrotrons and Free Electron Lasers, has reached one of its major milestones: a full 2-MegaPixel (P2M) system (uninterrupted 4 × 4 cm2 active area) has already seen its first light.Smaller prototypes of the device, a monolithic active pixel sensor based on CMOS technology, have already been fully characterised, and have demonstrated high frame rate, large dynamic range, and relatively high quantum efficiency.The PERCIVAL modular layout allows for clover-leaf like arrangement of up to four P2M systems. Moreover, it will be post-processed in order to achieve a high quantum efficiency in its primary energy range (250 eV to 1 keV).We will present the P2M system, its status and newest results, bring these in context with achieved prototype performance, and outline future steps. 
  •  
23.
  • Ehn, Sebastian, et al. (författare)
  • X-ray deconvolution microscopy
  • 2016
  • Ingår i: Biomedical Optics Express. - 2156-7085. ; 7:4, s. 1227-1239
  • Tidskriftsartikel (refereegranskat)abstract
    • Recent advances in single-photon-counting detectors are enabling the development of novel approaches to reach micrometer-scale resolution in x-ray imaging. One example of such a technology are the MEDIPIX3RX-based detectors, such as the LAMBDA which can be operated with a small pixel size in combination with real-time on-chip charge-sharing correction. This characteristic results in a close to ideal, box-like point spread function which we made use of in this study. The proposed method is based on raster-scanning the sample with sub-pixel sized steps in front of the detector. Subsequently, a deconvolution algorithm is employed to compensate for blurring introduced by the overlap of pixels with a well defined point spread function during the raster-scanning. The presented approach utilizes standard laboratory x-ray equipment while we report resolutions close to 10 mu m. The achieved resolution is shown to follow the relationship p/n with the pixel-size p of the detector and the number of raster-scanning steps n. (C) 2016 Optical Society of America
  •  
24.
  • Ekeberg, Tomas, et al. (författare)
  • Single-shot diffraction data from the Mimivirus particle using an X-ray free-electron laser
  • 2016
  • Ingår i: Scientific Data. - : Springer Science and Business Media LLC. - 2052-4463. ; 3
  • Tidskriftsartikel (refereegranskat)abstract
    • Free-electron lasers (FEL) hold the potential to revolutionize structural biology by producing X-ray pules short enough to outrun radiation damage, thus allowing imaging of biological samples without the limitation from radiation damage. Thus, a major part of the scientific case for the first FELs was three-dimensional (3D) reconstruction of non-crystalline biological objects. In a recent publication we demonstrated the first 3D reconstruction of a biological object from an X-ray FEL using this technique. The sample was the giant Mimivirus, which is one of the largest known viruses with a diameter of 450 nm. Here we present the dataset used for this successful reconstruction. Data-analysis methods for single-particle imaging at FELs are undergoing heavy development but data collection relies on very limited time available through a highly competitive proposal process. This dataset provides experimental data to the entire community and could boost algorithm development and provide a benchmark dataset for new algorithms.
  •  
25.
  • Ekeberg, Tomas, 1983-, et al. (författare)
  • Three-dimensional structure determination with an X-ray laser
  • Annan publikation (övrigt vetenskapligt/konstnärligt)abstract
    • Three-dimensional structure determination of a non-crystalline virus has been achieved from a set of randomly oriented continuous diffraction patterns captured with an X-ray laser. Intense, ultra-short X-ray pulses intercepted a beam of single mimivirus particles, producing single particle X-ray diffraction patterns that are assembled into a three-dimensional amplitude distribution based on statistical consistency. Phases are directly retrieved from the assembled Fourier distribution to synthesize a three-dimensional image. The resulting electron density reveals a pseudo-icosahedral asymmetric virion structure with a compartmentalized interior, within which the DNA genome occupies only about a fifth of the volume enclosed by the capsid. Additional electron microscopy data indicate the genome has a chromatin-like fiber structure that has not previously been observed in a virus. 
  •  
26.
  • Fröjdh, Christer, et al. (författare)
  • Characterization of a pixellated CdTe detector with single-photon processing readout
  • 2006
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 563:563, s. 128-132
  • Tidskriftsartikel (refereegranskat)abstract
    • A 1mm thick pixellated CdTe detector bonded to the MEDIPIX2 [1] readout chip has been characterized using a monoenergetic microbeam at the ESRF. This is an extension of the tests previously reported in [2]. The results show that a full energy peak can be obtained when a narrow beam is focused in the centre of the pixel. There is also evidence of significant charge diffusion and fluorescence. The results indicate that the charge sharing is the most important problem and will cause loss of the energy information in an imaging application. The second problem is the fluorescence which limits the number of counts in the full energy peak even for hits in the centre of the pixel.
  •  
27.
  • Graafsma, Heinz, et al. (författare)
  • Detector developments for photon science at DESY
  • 2023
  • Ingår i: Frontiers in Physics. - : Frontiers Media SA. - 2296-424X. ; 11
  • Tidskriftsartikel (refereegranskat)abstract
    • The past, current and planned future developments of X-ray imagers in the Photon-Science Detector Group at DESY-Hamburg is presented. the X-ray imagers are custom developed and tailored to the different X-ray sources in Hamburg, including the storage ring PETRA III/IV; the VUV-soft X-ray free electron laser FLASH, and the European Free-Electron Laser. Each source puts different requirements on the X-ray detectors, which is described in detail, together with the technical solutions implemented. 
  •  
28.
  •  
29.
  • Graafsma, Heinz, et al. (författare)
  • PERCIVAL soft X-ray imager
  • 2013
  • Ingår i: IEEE Nuclear Science Symposium Conference Record. - : IEEE conference proceedings. - 9781479905348 ; , s. Art. no. 6829506-
  • Konferensbidrag (refereegranskat)abstract
    • Our goal is to provide the scientific community with a large (10cm × 10cm) pixellated detector featuring a large dynamic range (1-105 photons), good spatial resolution (27μm), good Quantum Efficiency (QE) in the low energy range (250eV-1keV), variable readout speed (up to 120 frames/s), i.e. with characteristics compatible with user needs at today's of low-energy Free Electron Lasers (FEL) and synchrotron sources. © 2013 IEEE.
  •  
30.
  • Greiffenberg, D., et al. (författare)
  • Optimization of the noise performance of the AGIPD prototype chips
  • 2013
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 8:10, s. Art. no. P10022-
  • Tidskriftsartikel (refereegranskat)abstract
    • The charge integrating readout electronics AGIPD (adaptive gain integrating pixel detector) is a hybrid detector system developed for the European XFEL. It features a threefold dynamic gain switching to be able to resolve single photons and to cover a dynamic range of 104·12.4 keV photons. As a result of dynamic gain switching, single photon resolution will be achieved in the high gain stage, while the maximum dynamic range will be reached in the low gain stage. The specification to resolve single photons requires a signal-over-noise ratio of at least 10 for a single incoming photon with an energy of 12.4 keV. When using a silicon sensor, that translates to an equivalent noise charge of less than 343 e-. Several AGIPD prototype chips have been designed and characterized, particularly focusing on the noise performance. During the testing phase, the dominant noise sources were identified and the corresponding circuit blocks were improved in the subsequent ASICs. This paper reports on the procedures to identify the dominating noise sources, the optimization process of the circuit blocks and discusses the effect of the optimization on the noise performance.© 2013 IOP Publishing Ltd and Sissa Medialab srl.
  •  
31.
  • Greiffenberg, D., et al. (författare)
  • Towards AGIPD1.0 : Optimization of the dynamic range and investigation of a pixel input protection
  • 2014
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 9:6, s. Art. no. P06001-
  • Tidskriftsartikel (refereegranskat)abstract
    • AGIPD is a charge integrating, hybrid pixel readout ASIC, which is under development for the European XFEL [1,2]. A dynamic gain switching logic at the output of the preamplifier (preamp) is used to provide single photon resolution as well as covering a dynamic range of at least 104·12.4 keV photons [3,4]. Moreover, at each point of the dynamic range the electronics noise should be lower than the Poisson fluctuations, which is especially challenging at the points of gain switching. This paper reports on the progress of the chip design on the way to the first full-scale chip AGIPD1.0, focusing on the optimization of the dynamic range and the implementation of protection circuits at the preamplifier input to avoid pixel destruction due to high intense spots. © 2014 IOP Publishing Ltd and Sissa Medialab srl.
  •  
32.
  • Hatsui, Takaki, et al. (författare)
  • X-ray imaging detectors for synchrotron and XFEL sources
  • 2015
  • Ingår i: IUCRJ. - 2052-2525. ; 2, s. 371-383
  • Tidskriftsartikel (refereegranskat)abstract
    • Current trends for X-ray imaging detectors based on hybrid and monolithic detector technologies are reviewed. Hybrid detectors with photon-counting pixels have proven to be very powerful tools at synchrotrons. Recent developments continue to improve their performance, especially for higher spatial resolution at higher count rates with higher frame rates. Recent developments for X-ray free-electron laser (XFEL) experiments provide high-frame-rate integrating detectors with both high sensitivity and high peak signal. Similar performance improvements are sought in monolithic detectors. The monolithic approach also offers a lower noise floor, which is required for the detection of soft X-ray photons. The link between technology development and detector performance is described briefly in the context of potential future capabilities for X-ray imaging detectors.
  •  
33.
  • Jo, W., et al. (författare)
  • Nanosecond X-ray photon correlation spectroscopy using pulse time structure of a storage-ring source
  • 2021
  • Ingår i: IUCrJ. - : International Union of Crystallography. - 2052-2525. ; 8, s. 124-130
  • Tidskriftsartikel (refereegranskat)abstract
    • X-ray photon correlation spectroscopy (XPCS) is a routine technique to study slow dynamics in complex systems at storage-ring sources. Achieving nanosecond time resolution with the conventional XPCS technique is, however, still an experimentally challenging task requiring fast detectors and sufficient photon flux. Here, the result of a nanosecond XPCS study of fast colloidal dynamics is shown by employing an adaptive gain integrating pixel detector (AGIPD) operated at frame rates of the intrinsic pulse structure of the storage ring. Correlation functions from single-pulse speckle patterns with the shortest correlation time of 192 ns have been calculated. These studies provide an important step towards routine fast XPCS studies at storage rings. © 2021.
  •  
34.
  • Johansson, Linda C, 1983, et al. (författare)
  • Lipidic phase membrane protein serial femtosecond crystallography.
  • 2012
  • Ingår i: Nature methods. - : Springer Science and Business Media LLC. - 1548-7105 .- 1548-7091. ; 9:3, s. 263-265
  • Tidskriftsartikel (refereegranskat)abstract
    • X-ray free electron laser (X-FEL)-based serial femtosecond crystallography is an emerging method with potential to rapidly advance the challenging field of membrane protein structural biology. Here we recorded interpretable diffraction data from micrometer-sized lipidic sponge phase crystals of the Blastochloris viridis photosynthetic reaction center delivered into an X-FEL beam using a sponge phase micro-jet.
  •  
35.
  • Kassemeyer, Stephan, et al. (författare)
  • Femtosecond free-electron laser x-ray diffraction data sets for algorithm development
  • 2012
  • Ingår i: Optics Express. - 1094-4087. ; 20:4, s. 4149-4158
  • Tidskriftsartikel (refereegranskat)abstract
    • We describe femtosecond X-ray diffraction data sets of viruses and nanoparticles collected at the Linac Coherent Light Source. The data establish the first large benchmark data sets for coherent diffraction methods freely available to the public, to bolster the development of algorithms that are essential for developing this novel approach as a useful imaging technique. Applications are 2D reconstructions, orientation classification and finally 3D imaging by assembling 2D patterns into a 3D diffraction volume.
  •  
36.
  • Khromova, A., et al. (författare)
  • Report on recent results of the PERCIVAL soft X-ray imager
  • 2016
  • Ingår i: Journal of Instrumentation. - : IOP. - 1748-0221. ; 11:November
  • Tidskriftsartikel (refereegranskat)abstract
    • The PERCIVAL (Pixelated Energy Resolving CMOS Imager, Versatile And Large) soft X-ray 2D imaging detector is based on stitched, wafer-scale sensors possessing a thick epi-layer, which together with back-thinning and back-side illumination yields elevated quantum efficiency in the photon energy range of 125–1000 eV. Main application fields of PERCIVAL are foreseen in photon science with FELs and synchrotron radiation. This requires high dynamic range up to 105 ph @ 250 eV paired with single photon sensitivity with high confidence at moderate frame rates in the range of 10–120 Hz. These figures imply the availability of dynamic gain switching on a pixel-by-pixel basis and a highly parallel, low noise analog and digital readout, which has been realized in the PERCIVAL sensor layout. Different aspects of the detector performance have been assessed using prototype sensors with different pixel and ADC types. This work will report on the recent test results performed on the newest chip prototypes with the improved pixel and ADC architecture. For the target frame rates in the 10–120 Hz range an average noise floor of 14e− has been determined, indicating the ability of detecting single photons with energies above 250 eV. Owing to the successfully implemented adaptive 3-stage multiple-gain switching, the integrated charge level exceeds 4 centerdot 106 e− or 57000 X-ray photons at 250 eV per frame at 120 Hz. For all gains the noise level remains below the Poisson limit also in high-flux conditions. Additionally, a short overview over the updates on an oncoming 2 Mpixel (P2M) detector system (expected at the end of 2016) will be reported.
  •  
37.
  • Klačková, I., et al. (författare)
  • Five years operation experience with the AGIPD detectors at the European XFEL
  • 2023
  • Ingår i: Proceedings of SPIE - The International Society for Optical Engineering. - : SPIE - International Society for Optical Engineering. - 9781510662827
  • Konferensbidrag (refereegranskat)abstract
    • The European X-ray Free Electron Laser (EuXFEL) began its user operation five years ago, opening and offering new research possibilities. The facility delivers high brilliance, ultra-short, spatially coherent X-ray pulses with a high repetition rate to six instruments (FXE, SPB/SFX, MID, HED, SCS and SQS) by means of three different beamlines (SASE 1, SASE 2 and SASE 3). One of the first detectors used for early-stage experiments was the Adaptive Gain Integrating Pixel Detector (AGIPD), custom designed to meet the challenging needs of scientific instruments. The AGIPD is a megahertz-rate integrating hybrid megapixel camera with a per-pixel adaptive gain amplification, allowing the integration of up to 104 of 12 keV photons per pixel in its low gain stage. Currently, three scientific instruments, namely SPB/SFX, MID and HED employ the AGIPD systems, the latter mentioned using a prototype, half-megapixel camera with an upgraded version of readout ASICs. The AGIPDs at EuXFEL are successfully used for experimental techniques like serial femtosecond crystallography, MHz single particle imaging, MHz X-ray photon correlation spectroscopy or MHz diffraction of materials under high pressures in a diamond anvil cell. Since September 2017, the AGIPD is continuously used and has become an established detector technology, with further advancements and developments planned. Delivering quality experimental data requires reliable and reproducible detector characterisation and calibration that have to be performed regularly with a continuous improvement of correction methods in close collaboration with scientific instruments. This work summarises five years of experience operating the AGIPD detectors at the EuXFEL scientific instruments. It gives an overview of scientific capabilities and examples of successful studies performed with AGIPD detectors. Moreover, challenges concerning detector calibration and characterisation are presented. 
  •  
38.
  • Koopmann, Rudolf, et al. (författare)
  • In vivo protein crystallization opens new routes in structural biology
  • 2012
  • Ingår i: Nature Methods. - : Springer Science and Business Media LLC. - 1548-7091 .- 1548-7105. ; 9:3, s. 259-262
  • Tidskriftsartikel (refereegranskat)abstract
    • Protein crystallization in cells has been observed several times in nature. However, owing to their small size these crystals have not yet been used for X-ray crystallographic analysis. We prepared nano-sized in vivo–grown crystals of Trypanosoma brucei enzymes and applied the emerging method of free-electron laser-based serial femtosecond crystallography to record interpretable diffraction data. This combined approach will open new opportunities in structural systems biology.
  •  
39.
  • Loh, N. Duane, et al. (författare)
  • Sensing the wavefront of x-ray free-electron lasers using aerosol spheres
  • 2013
  • Ingår i: Optics Express. - 1094-4087. ; 21:10, s. 12385-12394
  • Tidskriftsartikel (refereegranskat)abstract
    • Characterizing intense, focused x-ray free electron laser (FEL) pulses is crucial for their use in diffractive imaging. We describe how the distribution of average phase tilts and intensities on hard x-ray pulses with peak intensities of 1021 W/m(2) can be retrieved from an ensemble of diffraction patterns produced by 70 nm-radius polystyrene spheres, in a manner that mimics wavefront sensors. Besides showing that an adaptive geometric correction may be necessary for diffraction data from randomly injected sample sources, our paper demonstrates the possibility of collecting statistics on structured pulses using only the diffraction patterns they generate and highlights the imperative to study its impact on single-particle diffractive imaging.
  •  
40.
  • Lomb, Lukas, et al. (författare)
  • Radiation damage in protein serial femtosecond crystallography using an x-ray free-electron laser
  • 2011
  • Ingår i: Physical Review B. Condensed Matter and Materials Physics. - 1098-0121 .- 1550-235X. ; 84:21, s. 214111-1-214111-6
  • Tidskriftsartikel (refereegranskat)abstract
    • X-ray free-electron lasers deliver intense femtosecond pulses that promise to yield high resolution diffraction data of nanocrystals before the destruction of the sample by radiation damage. Diffraction intensities of lysozyme nanocrystals collected at the Linac Coherent Light Source using 2 keV photons were used for structure determination by molecular replacement and analyzed for radiation damage as a function of pulse length and fluence. Signatures of radiation damage are observed for pulses as short as 70 fs. Parametric scaling used in conventional crystallography does not account for the observed effects.
  •  
41.
  • Marras, Alessandro, et al. (författare)
  • Characterization of the Percival detector with soft X-rays
  • 2021
  • Ingår i: Journal of Synchrotron Radiation. - 0909-0495 .- 1600-5775. ; 28, s. 131-145
  • Tidskriftsartikel (refereegranskat)abstract
    • In this paper the back-side-illuminated Percival 2-Megapixel (P2M) detector is presented, along with its characterization by means of optical and X-ray photons. For the first time, the response of the system to soft X-rays (250 eV to 1 keV) is presented. The main performance parameters of the first detector are measured, assessing the capabilities in terms of noise, dynamic range and single-photon discrimination capability. Present limitations and coming improvements are discussed.
  •  
42.
  •  
43.
  • Marras, A., et al. (författare)
  • Development of CoRDIA : An Imaging Detector for next-generation Synchrotron Rings and Free Electron Lasers
  • 2022
  • Ingår i: Journal of Physics. - : Institute of Physics (IOP).
  • Konferensbidrag (refereegranskat)abstract
    • An x-ray imager is being developed for use in diffraction-limited synchrotron rings and continuous wave free electron lasers. The imager is named CoRDIA (COntinuous Readout Digitising Imager Array) and aims at achieving continuous operation at a frame rate in excess of 100kHz. Other goals include single-photon sensitivity at 12 keV (or below), a full well in excess of 10k photon/pixel/image, and a 100μm pixel pitch. The detector ASIC will be compatible with multiple sensor materials to cover different energy ranges. Exploratory prototypes of the readout ASIC (basic circuital blocks) have been manufactured in TSMC 65nm technology: they are presently under test. 
  •  
44.
  • Marras, A., et al. (författare)
  • Development of the Continuous Readout Digitising Imager Array detector
  • 2024
  • Ingår i: Journal of Instrumentation. - : IOP Publishing. - 1748-0221. ; 19:3
  • Tidskriftsartikel (refereegranskat)abstract
    • The CoRDIA project aims to develop an X-ray imager capable of continuous operation in excess of 100 kframe/s. The goal is to provide a suitable instrument for Photon Science experiments at diffraction-limited Synchrotron Rings and Free Electron Lasers considering Continuous Wave operation. Several chip prototypes were designed in a 65 nm process: in this paper we will present an overview of the challenges and solutions adopted in the ASIC design. 
  •  
45.
  • Marras, A., et al. (författare)
  • Experimental characterization of the PERCIVAL soft X-ray detector
  • 2016
  • Ingår i: 2015 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2015. - : Institute of Electrical and Electronics Engineers (IEEE). - 9781467398626
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
    • Considerable interest has been manifested for the use of high-brilliance X-ray synchrotron sources and X-ray Free-Electron Lasers for the investigation of samples.
  •  
46.
  • Marras, A., et al. (författare)
  • Front end electronics for European XFEL sensor : The AGIPD project
  • 2013
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 731, s. 79-82
  • Tidskriftsartikel (refereegranskat)abstract
    • The AGIPD (Adaptive Gain Integrating Pixel Detector) is a detector under development, to be used in the European X-ray Free-Electron Laser (XFEL). The constraints imposed by the XFEL source are discussed, and the solutions implemented to cope with them are explained. The present status of the project is reported, along with results achieved in terms of noise, memory depth, and radiation tolerance. © 2013 Elsevier B.V.
  •  
47.
  • Marras, Alessandro, et al. (författare)
  • Percival : A soft x-ray imager for synchrotron rings and free electron lasers
  • 2019
  • Ingår i: AIP Conference Proceedings. - : American Institute of Physics (AIP). - 0094-243X. - 9780735417823
  • Konferensbidrag (refereegranskat)abstract
    • In this paper, we are presenting the Percival detector, a monolithic CMOS Imager for detection of soft x-rays in Synchrotron Rings and Free Electron Lasers. The imager consists in a 2D array of many (2M) small (27um pitch) pixels, without dead or blind zones in the imaging area. The imager achieves low noise and high dynamic range by means of an adaptive-gain in-pixel circuitry, that has been validated on prototypes. The imager features on-chip Analogue-to-Digital conversion to 12+1 bits, and has a readout speed which is compatible with most of Free Electron Laser Facilities. For direct detection of low-energy x-rays, the imager is back-illuminated and post-processed to achieve 100% fill factor. 
  •  
48.
  • Marras, A., et al. (författare)
  • Percival P2M-FSI detector : First test at a Synchrotron Ring beamline with tender x-ray photons
  • 2019
  • Ingår i: 2019 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2019. - : IEEE. - 9781728141640
  • Konferensbidrag (refereegranskat)abstract
    • In this paper, we are presenting the results of the first test of the Percival P2M-FSI detector with tender x-rays photons at a synchrotron beamline. Percival is a monolithic CMOS Imager for detection of x-rays in Synchrotron Rings and Free Electron Lasers: the Front-Side-Illuminated (FSI) version of the detector has been proven able to successfully distinguish tender (2keV) x-ray single photons. 
  •  
49.
  • Marras, A., et al. (författare)
  • Vertically integrated circuits : Example of an application to an x-ray detector
  • 2014
  • Ingår i: 2014 21st IEEE International Conference on Electronics, Circuits and Systems, ICECS 2014. - 9781479942428 ; , s. 243-246
  • Konferensbidrag (refereegranskat)abstract
    • Replacing planar circuits with vertically integrated ones allows to increment circuit functionalities on a given silicon area, while avoiding some of the problems associated with aggressively scaled technology nodes. This is particularly true for applications likely to subject circuits to high doses of ionizing radiation (such of x-ray detectors to be used in synchrotron rings and Free Electron Lasers), since the degradation mechanisms of some of the innovative materials to be used in most recent nodes have not been fully characterized yet. In this paper, an evolution is presented for the readout ASIC of a pixelated x-ray detector to be used for such applications. The readout circuit is distributed in a stack of two vertically interconnected tiers, thus doubling the circuitry resident in each pixel without increasing the pixel pitch (and thus compromising spatial resolution of the detector). A first prototype has been designed and manufactured, using a commercial 130 nm CMOS technology. Design issues are discussed, along with preliminary characterization results. © 2014 IEEE.
  •  
50.
  • Mezza, D., et al. (författare)
  • Calibration methods for charge integrating detectors
  • 2022
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 1024
  • Tidskriftsartikel (refereegranskat)abstract
    • Since the introduction of the extremely intense X-ray free electron lasers, the need for low noise, high dynamic range and potentially fast charge integrating detectors has increased significantly. Among all the problems that research and development groups have to face in the development of such detectors, their calibration represents one of the most challenging and the collaboration between the detector development and user groups is of fundamental importance. The main challenge is to develop a calibration suite that is capable to test the detector over a wide dynamic range, with a high granularity and a very high linearity, together with a certain radiation tolerance and the possibility to well define the timings and the synchronization with the detector. Practical considerations have also to be made like the possibility to calibrate the detector in a reasonable time, the availability of the calibration source at the experimental place and so on. Such a calibration test suite is often not represented by a single source but by several sources that can cover different parts of the dynamic range and that need to be cross calibrated to have a final calibration curve. In this respect an essential part of the calibration is also to develop a mathematical model that allows calibrating the entire dynamic range, taking into account features that are calibration source and/or detector specific. The aim of this contribution is to compare the calibration for the AGIPD detector using several calibration sources such as internal current source, backside pulsing, IR pulsed laser, LED light and mono-energetic protons. The mathematical procedure used to calibrate the different sources will be discussed in great detail showing how to take into account a few shortcomings (like pixel coupling) that are common for many charge integrating detectors. This work has been carried out in the frame of the AGIPD project for the European X-ray Free Electron Laser. 
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-50 av 81
Typ av publikation
tidskriftsartikel (56)
konferensbidrag (17)
forskningsöversikt (4)
bokkapitel (2)
annan publikation (1)
doktorsavhandling (1)
visa fler...
visa färre...
Typ av innehåll
refereegranskat (78)
övrigt vetenskapligt/konstnärligt (3)
Författare/redaktör
Graafsma, Heinz (80)
Marras, A. (40)
Lange, S. (31)
Zimmer, M. (30)
Trunk, U (26)
Hirsemann, H. (24)
visa fler...
Klyuev, A. (23)
Becker, J. (21)
Shi, X. (20)
Greiffenberg, D. (20)
Schmitt, B. (20)
Zhang, J. (19)
Xia, Q. (19)
Mozzanica, A. (19)
Dinapoli, R. (18)
Sheviakov, I. (17)
Schwandt, J. (17)
Goettlicher, P. (16)
Jack, S. (16)
Klanner, R. (15)
Bianco, L. (15)
Allahgholi, A. (14)
Mezza, D. (14)
Rah, S. (14)
Smoljanin, S. (14)
Hirsemann, Helmut (14)
Correa, J. (14)
Barty, Anton (14)
Bajt, Saša (14)
Gumprecht, Lars (14)
Aquila, Andrew (12)
Delfs, A. (12)
Erk, Benjamin (12)
Rudenko, Artem (12)
Rolles, Daniel (12)
Shoeman, Robert L (12)
Foucar, Lutz (12)
Hartmann, Robert (12)
Rudek, Benedikt (12)
Maia, Filipe R. N. C ... (12)
Barthelmess, Miriam (12)
Bostedt, Christoph (12)
Holl, Peter (12)
Kimmel, Nils (12)
Lomb, Lukas (12)
Reich, Christian (12)
Schlichting, Ilme (12)
Schulz, Joachim (12)
Soltau, Heike (12)
Ullrich, Joachim (12)
visa färre...
Lärosäte
Mittuniversitetet (68)
Uppsala universitet (15)
Högskolan i Gävle (6)
Göteborgs universitet (3)
Sveriges Lantbruksuniversitet (3)
Kungliga Tekniska Högskolan (1)
visa fler...
Chalmers tekniska högskola (1)
visa färre...
Språk
Engelska (81)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (47)
Teknik (43)
Medicin och hälsovetenskap (4)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy