SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Levick Christina) "

Sökning: WFRF:(Levick Christina)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Selvaraj, Emmanuel Anandraj, et al. (författare)
  • Diagnostic accuracy of elastography and magnetic resonance imaging in patients with NAFLD : a systematic review and meta-analysis
  • 2021
  • Ingår i: Journal of Hepatology. - : Elsevier. - 0168-8278 .- 1600-0641. ; 75:4, s. 770-785
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND AND AIMS: Vibration-controlled transient elastography (VCTE), point shear wave elastography (pSWE), two-dimensional shear wave elastography (2DSWE), magnetic resonance elastography (MRE), and magnetic resonance imaging (MRI) are proposed as non-invasive tests for patients with non-alcoholic fatty liver disease (NAFLD). This study evaluated their diagnostic accuracy for liver fibrosis and non-alcoholic steatohepatitis (NASH).METHODS: PubMED/MEDLINE, EMBASE and the Cochrane Library were searched for studies examining the diagnostic accuracy of these index tests against histology as the reference standard, in adult patients with NAFLD. Two authors independently screened and assessed methodological quality of studies and extracted data. Summary estimates of sensitivity, specificity and area under the curve (sAUC) were calculated for fibrosis stages and NASH, using a random effects bivariate logit-normal model.RESULTS: We included 82 studies (14,609 patients). Meta-analysis for diagnosing fibrosis stages was possible in 53 VCTE, 11 MRE, 12 pSWE and four 2DSWE studies, and for diagnosing NASH in four MRE studies. sAUC for diagnosis of significant fibrosis were: 0.83 for VCTE, 0.91 for MRE, 0.86 for pSWE and 0.75 for 2DSWE. sAUC for diagnosis of advanced fibrosis were: 0.85 for VCTE, 0.92 for MRE, 0.89 for pSWE and 0.72 for 2DSWE. sAUC for diagnosis of cirrhosis were: 0.89 for VCTE, 0.90 for MRE, 0.90 for pSWE and 0.88 for 2DSWE. MRE had sAUC of 0.83 for diagnosis of NASH. Three (4%) studies reported intention-to-diagnose analyses and 15 (18%) studies reported diagnostic accuracy against pre-specified cut-offs.CONCLUSIONS: When elastography index tests are acquired successfully, they have acceptable diagnostic accuracy for advanced fibrosis and cirrhosis. The potential clinical impact of these index tests cannot be assessed fully as intention-to-diagnose analyses and validation of pre-specified thresholds are lacking.LAY SUMMARY: Non-invasive tests that measure liver stiffness or use magnetic resonance imaging (MRI) have been suggested as alternatives to liver biopsy in assessing the severity of liver scarring (fibrosis) and fatty inflammation (steatohepatitis) in patients with non-alcoholic fatty liver disease (NAFLD). In this study, we summarise the results of previously published studies on how accurately these non-invasive tests can diagnose liver fibrosis and inflammation, using liver biopsy as the reference. We found that some techniques that measure liver stiffness had a good performance for the diagnosis of severe liver scarring.
  •  
2.
  • Vali, Yasaman, et al. (författare)
  • Enhanced liver fibrosis test for the non-invasive diagnosis of fibrosis in patients with NAFLD : A systematic review and meta-analysis
  • 2020
  • Ingår i: Journal of Hepatology. - : Elsevier. - 0168-8278 .- 1600-0641. ; 73:2, s. 252-262
  • Forskningsöversikt (refereegranskat)abstract
    • BACKGROUND AND AIMS: The Enhanced Liver Fibrosis (ELF) test is a non-invasive biomarker, suggested as an appropriate test for advanced liver fibrosis in non-alcoholic fatty liver disease (NAFLD). This systematic review aimed to provide summary estimates of the accuracy of this test against biopsy.METHODS: In this systematic review, we searched MEDLINE, Embase, Web of Science and the Cochrane Library, for studies included NAFLD patients and undertook both liver biopsy as the reference standard and the ELF test. Two authors independently screened the references, extracted the data and assessed the quality of included studies. Due to the variation in reported thresholds, we used a multiple thresholds random effects model for meta-analysis (diagmeta R-package).RESULTS: The meta-analysis of 11 studies reporting advanced fibrosis and five studies reporting significant fibrosis showed sensitivity of >0.90 of the ELF test for excluding fibrosis at threshold of 7.7. However, as a diagnostic test at high thresholds, the test showed specificity and positive predictive value >0.80, only in very high-prevalence settings (>50%). Desiring specificity of 0.90 for advanced and significant fibrosis resulted in thresholds of 10.18 (sensitivity: 0.57) and 9.86 (sensitivity: 0.55), respectively.CONCLUSION: The ELF test showed high sensitivity but limited specificity to exclude advanced and significant fibrosis at low cutoffs. The diagnostic performance of the test at higher thresholds was found to be more limited in low prevalence settings. We conclude that clinicians should carefully consider the likely disease prevalence in their practice setting and adopt suitable test thresholds to achieve the desired test performance.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy