SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Selleng K) "

Search: WFRF:(Selleng K)

  • Result 1-6 of 6
Sort/group result
   
EnumerationReferenceCoverFind
1.
  •  
2.
  •  
3.
  •  
4.
  • Greinacher, A, et al. (author)
  • Heparin-induced thrombocytopenia : a prospective study on the incidence, platelet-activating capacity and clinical significance of antiplatelet factor 4/heparin antibodies of the IgG, IgM, and IgA classes.
  • 2007
  • In: Journal of Thrombosis and Haemostasis. - : Elsevier BV. - 1538-7933 .- 1538-7836. ; 5:8, s. 1666-73
  • Journal article (peer-reviewed)abstract
    • INTRODUCTION: Platelet-activating antiplatelet factor 4/heparin (anti-PF4/heparin) antibodies are the major cause of heparin-induced thrombocytopenia (HIT). However, the relative utility of functional (platelet activation) vs. antigen [enzyme-immunoassay (EIA)] assays, and the significance of assay discrepancies remain unresolved. METHODS: Consecutive patient sera (n = 1650) referred for diagnostic HIT testing were screened prospectively by both the heparin-induced platelet activation (HIPA) test and anti-PF4/heparin EIA - including individual classes (IgG, IgA, IgM) - with clinical correlations studied. Platelet microparticle and annexin-V-binding properties of the sera were also investigated. RESULTS: Only 205 (12.4%) sera tested positive in either the HIPA and/or EIA: 95 (46.3%) were positive in both, 109 (53.1%) were only EIA-positive, and, notably, only one serum was HIPA-positive/EIA-negative. Of 185 EIA-positive sera, only 17.6% had detectable IgM and/or IgA without detectable IgG. Among sera positive for EIA IgG, optical density values were higher when the sera were HIPA-positive (1.117 vs. 0.768; P < 0.0001), with widely overlapping values. Two HIPA-positive but EIA-IgG-negative sera became HIPA-negative following IgG depletion, suggesting platelet-activating antibodies against non-PF4-dependent antigens. Clinical correlations showed that HIPA-negative/EIA-positive patients did not develop thrombosis and had reasons other than HIT to explain thrombocytopenia. IgM/A antibodies did not increase microparticle penetration, but increased annexin-V binding. CONCLUSIONS: The anti-PF4/heparin EIA has high ( approximately 99%) sensitivity for HIT. However, only about half of EIA-positive patients are likely to have HIT. Anti-PF4/heparin antibodies of IgM/A class and non-PF4-dependent antigens have only a minor role in HIT.
  •  
5.
  • Greinacher, A, et al. (author)
  • Heparin-induced thrombocytopenia : towards standardization of platelet factor 4/heparin antigen tests.
  • 2010
  • In: Journal of Thrombosis and Haemostasis. - : Elsevier BV. - 1538-7933 .- 1538-7836. ; 8:9, s. 2025-31
  • Journal article (peer-reviewed)abstract
    • BACKGROUND: Laboratory confirmation of heparin-induced thrombocytopenia (HIT) is based on detection of heparin-dependent platelet-activating antibodies. Platelet factor 4 (PF4)/heparin enzyme-immunoassays (EIA) are a widely available surrogate for platelet-activating antibodies. OBJECTIVE: Defining the optical density (OD) reactivity profiles of a PF4/heparin EIA in reference subject and patient populations and the correlation of the EIA results (expressed in OD units) with the prevalence of platelet-activating antibodies. PATIENTS/METHODS: Using quantile regression we determined the 97.5th percentile of PF4/heparin-immunoglobulin G (IgG) EIA reactivities in non-heparin-treated individuals [blood donors (n = 935)] and patients before heparin therapy (n = 1207). In patients with suspected HIT, we compared the correlation of EIA-IgG reactivities (Greifswald laboratory; n = 2821) and the heparin-induced platelet activation assay (HIPA) with the correlation of reactivities of another EIA-IgG (McMaster laboratory; n = 1956) with the serotonin-release assay (SRA). RESULTS: PF4/heparin-IgG EIA OD reactivities had a lower OD 97.5th percentile in blood donors compared with patient groups before heparin treatment (P < 0.001). The percentage of sera testing positive in the functional assays strongly correlated with PF4/heparin-IgG EIA OD reactivities in both laboratories with very similar results (correlation coefficient > 0.9) when normalized OD ranges (maximum OD divided by 10) were used instead of absolute OD values. CONCLUSIONS: Results of PF4/heparin-IgG EIA should not be reported as only positive or negative as there is no single acceptable cut-off value. Instead, reporting PF4/heparin-IgG EIA OD results in ranges allows for risk-stratified prediction for presence of platelet-activating antibodies. Use of normalized OD ranges permits a standardized approach for inter-laboratory comparisons.
  •  
6.
  • Weimann, G, et al. (author)
  • Glucosamine sulfate does not crossreact with the antibodies of patients with heparin-induced thrombocytopenia.
  • 2001
  • In: European Journal of Haematology. - 0902-4441 .- 1600-0609. ; 66:3, s. 195-9
  • Journal article (peer-reviewed)abstract
    • OBJECTIVE: To assess the crossreactivity of glucosamine sulfate, used for treatment of degenerative joint disease with antibodies induced in heparin-induced thrombocytopenia (HIT). BACKGROUND: HIT is a severe adverse effect of heparin therapy induced by an immunological mechanism. The antibodies in HIT are induced by a complex of heparin and, in most cases, platelet factor 4. Hereby generation of the antigen is not strictly dependent on heparin. Heparin can be substituted by a variety of polysulfated carbohydrates. In vitro and in vivo crossreactivity of HIT antibodies has been demonstrated for a chemically polysulfated chondroitin-like substance (Arteparon, Luitpoldwerke, Munich, Germany), formerly used for chondroprotection. Another drug widely used in the treatment of degenerative joint disease is glucosamine sulfate. Glucosamine is a building block of glycosaminoglycans, of which heparin is the clinically most important. Many patients with degenerative joint disease use glucosamine sulfate. This group is also at the highest risk to develop HIT following joint replacement surgery. METHODS: We examined the interactions of glucosamine sulfate (DONA 200-S, Opfermann, Wiehl, Germany) with platelets and antibodies of patients with HIT in and without the presence of heparin. Sera of 5 HIT patients and platelets of 4 healthy donors were used. The binding of HIT antibodies to PF4/glucosamine sulfate complexes was assessed by an ELISA. RESULTS: HIT antibodies did not activate platelets in the presence of glucosamine sulfate in a serotonin-release assay. Preincubation with glucosamine sulfate did not inhibit platelet activation by HIT antibodies in the presence of heparin (0.2 IU/ml). Antibodies bonded to PF4/heparin but not to PF4/glucosamine sulfate complexes. CONCLUSIONS: In contrast to sulfated glycosaminoglycans, there is no evidence for an immunological crossreactivity of HIT antibodies between heparin and glucosamine sulfate.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-6 of 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view