SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "id:"swepub:oai:DiVA.org:hb-6298" "

Sökning: id:"swepub:oai:DiVA.org:hb-6298"

  • Resultat 1-1 av 1
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Buendia, Ruben, 1982, et al. (författare)
  • A Novel Approach for Removing the Hook Effect Artefact from Electrical Bioimpedance Spectroscopy Measurements
  • 2009
  • Ingår i: Journal of Physics: Conference Series. - : Institute of Physics Publishing Ltd.. - 1742-6596.
  • Konferensbidrag (refereegranskat)abstract
    • Very often in Electrical Bioimpedance (EBI) spectroscopy measurements the presence of stray capacitances creates a measurement artefact commonly known as Hook Effect. Such an artefact creates a hook-alike deviation of the EBI data noticeable when representing the measurement on the impedance plane. Such Hook Effect is noticeable at high frequencies but it also causes a data deviation at lower measurement frequencies. In order to perform any accurate analysis of the EBI spectroscopy data, the influence of the Hook Effect must be removed. An established method to compensate the hook effect is the well known Td compensation, which consist on multiplying the obtained spectrum, Zmeas() by a complex exponential in the form of exp[jTd]. Such a method cannot correct entirely the Hook Effect since the hook-alike deviation occurs a broad frequency range in both magnitude and phase of the measured impedance, and by using a real value for Td. First, a real value only modifies the phase of the measured impedance and second, it can only correct the Hook Effect at a single frequency. In addition, the process to select a value for Td by an iterative process with the aim to obtain the best Cole fitting lacks solid scientific grounds. In this work the Td compensation method is revisited and a modified approach for correcting the Hook Effect that includes a novel method for selecting the correcting values is proposed. The initial validation results confirm that the proposed method entirely corrects the Hook Effect at all frequencies.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-1 av 1
Typ av publikation
konferensbidrag (1)
Typ av innehåll
refereegranskat (1)
Författare/redaktör
Seoane, Fernando (1)
Gil-Pita, Roberto (1)
Buendia, Ruben, 1982 (1)
Lärosäte
Chalmers tekniska högskola (1)
Högskolan i Borås (1)
Språk
Engelska (1)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (1)
Teknik (1)
Medicin och hälsovetenskap (1)
År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy