1. |
- Strigård, Karin, 1958-, et al.
(författare)
-
Intrastomal 3D ultrasound : an inter- and intra-observer evaluation
- 2013
-
Ingår i: International Journal of Colorectal Disease. - : Springer-Verlag New York. - 0179-1958 .- 1432-1262. ; 28:1, s. 43-47
-
Tidskriftsartikel (refereegranskat)abstract
- The aim of this study was to determine intra- and interobserver reliability in 3D intrastomal ultrasound imaging of parastomal hernia and protrusion. A total of 40 patients were investigated. Two or three physicians evaluated the images twice, 1 month apart. Inter-observer agreement was 72 % with a kappa value 0.59. For the last 10 patients there was an agreement of 80 % with a kappa value of 0.70. Intraobserver agreement was 80 % for one observer and 95 % for the other. The learning curve levelled out at around 30 patients. Considering the learning curve of 30 patients, 3D intrastomal ultrasound is a reliable investigation method. 3D intrastomal ultrasonography has the potential to be the investigation of choice to differentiate between a bulge, a hernia, or a protrusion.
|
|