SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Beule A) srt2:(2010-2014)"

Sökning: WFRF:(Beule A) > (2010-2014)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Thompson, Alex J., et al. (författare)
  • In vivo measurements of diffuse reflectance and time-resolved autofluorescence emission spectra of basal cell carcinomas
  • 2012
  • Ingår i: Journal of Biophotonics. - : Wiley. - 1864-063X. ; 5:3, s. 240-254
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • We present a clinical investigation of diffuse reflectance and time-resolved autofluorescence spectra of skin cancer with an emphasis on basal cell carcinoma. A total of 25 patients were measured using a compact steady-state diffuse reflectance/fluorescence spectrometer and a fibre-optic-coupled multispectral time-resolved spectrofluorometer. Measurements were performed in vivo prior to surgical excision of the investigated region. Singular value decomposition was used to reduce the dimensionality of steady state diffuse reflectance and fluorescence spectra. Linear discriminant analysis was then applied to the measurements of basal cell carcinomas (BCCs) and used to predict the tissue disease state with a leave-one-out methodology. This approach was able to correctly diagnose 87% of the BCCs. With 445 nm excitation a decrease in the spectrally averaged fluorescence lifetime was observed between normal tissue and BCC lesions with a mean value of 886 ps. Furthermore, the fluorescence lifetime for BCCs was lower than that of the surrounding healthy tissue in all cases and statistical analysis of the data revealed that this decrease was significant (p = 0.002). (C) 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim)
  •  
2.
  • Mortier, P., et al. (författare)
  • A Novel Simulation Strategy for Stent Insertion and Deployment in Curved Coronary Bifurcations : Comparison of Three Drug-Eluting Stents
  • 2010
  • Ingår i: Annals of Biomedical Engineering. - : Springer Science and Business Media LLC. - 0090-6964 .- 1573-9686. ; 38:1, s. 88-99
  • Tidskriftsartikel (refereegranskat)abstract
    • The introduction of drug-eluting stents (DES) has reduced the occurrence of restenosis in coronary arteries. However, restenosis remains a problem in stented coronary bifurcations. This study investigates and compares three different second generation DESs when being implanted in the curved main branch of a coronary bifurcation with the aim of providing better insights into the related changes of the mechanical environment. The 3D bifurcation model is based on patient-specific angiographic data that accurately reproduce the in vivo curvatures of the vessel segments. The layered structure of the arterial wall and its anisotropic mechanical behavior are taken into account by applying a novel algorithm to define the fiber orientations. An innovative simulation strategy considering the insertion of a folded balloon catheter over a guide wire is proposed in order to position the stents within the curved vessel. Straightening occurs after implantation of all stents investigated. The resulting distributions of the wall stresses are strongly dependent on the stent design. Using a parametric modeling approach, two design modifications, which reduce the predicted maximum values of the wall stress, are proposed and analyzed.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy