  • Asplund, Sara, 1976, et al. (författare)
  • Extended analysis of the effect of learning with feedback on the detectability of pulmonary nodules in chest tomosynthesis
  • 2011
  • Ingår i: Progress in Biomedical Optics and Imaging - Proceedings of SPIE. - : SPIE. - 1605-7422. ; 7966
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • In chest tomosynthesis, low-dose projections collected over a limited angular range are used for reconstruction of section images of the chest, resulting in a reduction of disturbing anatomy at a moderate increase in radiation dose compared to chest radiography. In a previous study, we investigated the effects of learning with feedback on the detection of pulmonary nodules in chest tomosynthesis. Six observers with varying degrees of experience of chest tomosynthesis analyzed tomosynthesis cases for presence of pulmonary nodules. The cases were analyzed before and after learning with feedback. Multidetector computed tomography (MDCT) was used as reference. The differences in performance between the two readings were calculated using the jackknife alternative free-response receiver operating characteristics (JAFROC-2) as primary measure of detectability. Significant differences between the readings were found only for observers inexperienced in chest tomosynthesis. The purpose of the present study was to extend the statistical analysis of the results of the previous study, including JAFROC-1 analysis and FROC curves in the analysis. The results are consistent with the results of the previous study and, furthermore, JAFROC-1 gave lower p-values than JAFROC-2 for the observers who improved their performance after learning with feedback. © 2011 SPIE.
  •  
3.
  •  
4.
  • Asplund, Sara, 1976, et al. (författare)
  • Learning aspects and potential pitfalls regarding detection of pulmonary nodules in chest tomosynthesis and proposed related quality criteria.
  • 2011
  • Ingår i: Acta radiologica. - : SAGE Publications. - 1600-0455 .- 0284-1851. ; 52:5, s. 503-512
  • Tidskriftsartikel (refereegranskat)abstract
    • Background In chest tomosynthesis, low-dose projections collected over a limited angular range are used for reconstruction of an arbitrary number of section images of the chest, resulting in a moderately increased radiation dose compared to chest radiography. Purpose To investigate the effects of learning with feedback on the detection of pulmonary nodules for observers with varying experience of chest tomosynthesis, to identify pitfalls regarding detection of pulmonary nodules, and present suggestions for how to avoid them, and to adapt the European quality criteria for chest radiography and computed tomography (CT) to chest tomosynthesis. Material and Methods Six observers analyzed tomosynthesis cases for presence of nodules in a jackknife alternative free-response receiver-operating characteristics (JAFROC) study. CT was used as reference. The same tomosynthesis cases were analyzed before and after learning with feedback, which included a collective learning session. The difference in performance between the two readings was calculated using the JAFROC figure of merit as principal measure of detectability. Results Significant improvement in performance after learning with feedback was found only for observers inexperienced in tomosynthesis. At the collective learning session, localization of pleural and subpleural nodules or structures was identified as the main difficulty in analyzing tomosynthesis images. Conclusion The results indicate that inexperienced observers can reach a high level of performance regarding nodule detection in tomosynthesis after learning with feedback and that the main problem with chest tomosynthesis is related to the limited depth resolution.
  •  
5.
  •  
6.
  •  
7.
  • Johnsson, Åse (Allansdotter), 1966, et al. (författare)
  • A phantom study of nodule size evaluation with chest tomosynthesis and computed tomography.
  • 2010
  • Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 1742-3406 .- 0144-8420. ; 139:1-3, s. 140-143
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of the present study was to investigate nodule size measurements with chest tomosynthesis (TS) and computed tomography (CT). A 26-mm thick phantom, composed of a Polylite block with embedded spheres of different materials and sizes (4-20 mm), was scanned by both CT and TS. Six observers without prior knowledge of the true diameters of the spheres independently measured the diameter of the spheres on the CT and TS images. Four observers were allowed to change the window settings and two of the observers used predetermined fixed viewing conditions. The mean relative errors for all observers and all measured spheres compared with the known diameter of the spheres were 1.4 % (standard deviation, SD: 5.4 %) on CT images and -1.1 % (SD: 5.0 %) on TS images. With regard to the four observers where the window settings were at the discretion of the observer, the mean relative errors were 1.4 % (SD: 6.4 %) on CT images and -1.7 % (SD: 5.7 %) on TS images. Regarding the two observers using identical viewing conditions the mean relative error was 1.5 % (SD: 2.8 %) on CT images and 0.2 % (SD: 2.6 %) on TS images. In conclusion, the study suggests that nodule size measurements on chest TS might be an alternative to measurements on CT.
  •  
8.
  • Johnsson, Åse (Allansdotter), 1966, et al. (författare)
  • Overview of two years of clinical experience of chest tomosynthesis at Sahlgrenska University Hospital.
  • 2010
  • Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 1742-3406 .- 0144-8420. ; 139:1-3, s. 124-129
  • Tidskriftsartikel (refereegranskat)abstract
    • Since December 2006, approximately 3800 clinical chest tomosynthesis examinations have been performed at our department at Sahlgrenska University Hospital. A subset of the examinations has been included in studies of the detectability of pulmonary nodules, using computed tomography (CT) as the gold standard. Visibility studies, in which chest tomosynthesis and CT have been compared side-by side, have been used to determine the depiction potential of chest tomosynthesis. Comparisons with conventional chest radiography have been made. In the clinical setting, chest tomosynthesis has mostly been used as an additional examination. The most frequent indication for chest tomosynthesis has been suspicion of a nodule or tumour. In visibility studies, tomosynthesis has depicted over 90 % of the nodules seen on the CT scan. The corresponding figure for chest radiography has been <30 %. In the detection studies, the lesion-level sensitivity has been approximately 60 % for tomosynthesis and 20 % for chest radiography. In one of the detection studies, an analysis of all false-positive nodules was performed. This analysis showed that all findings had morphological correlates on the CT examinations. The majority of the false-positive nodules were localised in the immediate subpleural region. In conclusion, chest tomosynthesis is an improved chest radiography method, which can be used to optimise the use of CT resources, thereby reducing the radiation dose to the patient population. However, there are some limitations with chest tomosynthesis. For example, patients undergoing tomosynthesis have to be able to stand still and hold their breath firmly for 10 s. Also, chest tomosynthesis has a limited depth resolution, which may explain why pathology in the subpleural region is more difficult to interpret and artefacts from medical devices may occur.
  •  
9.
  • Johnsson, Åse (Allansdotter), 1966, et al. (författare)
  • Pulmonary nodule size evaluation with chest tomosynthesis.
  • 2012
  • Ingår i: Radiology. - : Radiological Society of North America (RSNA). - 1527-1315 .- 0033-8419. ; 265:1, s. 273-82
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To evaluate intra- and interobserver variability, as well as agreement for nodule size measurements on chest tomosynthesis and computed tomographic (CT) images. Materials and Methods: The Regional Ethical Review Board approved this study, and all participants gave written informed consent. Thirty-six segmented nodules in 20 patients were included in the study. Eight observers measured the left-to-right, inferior-to-superior, and longest nodule diameters on chest tomosynthesis and CT images. Intra- and interobserver repeatability, as well as agreement between measurements on chest tomosynthesis and CT images, were assessed as recommended by Bland and Altman. Results: The difference between the mean manual and the segmented diameter was -2.2 and -2.3 mm for left-to-right and -2.6 and -2.2 mm for the inferior-to-superior diameter for measurements on chest tomosynthesis and CT images, respectively. Intraobserver 95% limits of agreement (LOA) for the longest diameter ranged from a lower limit of -1.1 mm and an upper limit of 1.0 mm to -1.8 and 1.8 mm for chest tomosynthesis and from -0.6 and 0.9 mm to -3.1 and 2.2 mm for axial CT. Interobserver 95% LOA ranged from -1.3 and 1.5 mm to -2.0 and 2.1 mm for chest tomosynthesis and from -1.8 and 1.1 mm to -2.2 and 3.1 mm for axial CT. The 95% LOA concerning the mean of the observers' measurements of the longest diameter at chest tomosynthesis and axial CT were ±2.1 mm (mean measurement error, 0 mm). For the different observers, the 95% LOA between the modalities ranged from -2.2 and 1.6 mm to -3.2 and 2.8 mm. Conclusion: Measurements on chest tomosynthesis and CT images are comparable, because there is no evident bias between the modalities and the repeatability is similar. The LOA between measurements for the two modalities raise concern if measurements from chest tomosynthesis and CT were to be used interchangeably. © RSNA, 2012 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.12111459/-/DC1.
  •  