  • Ekqvist, Susanne, et al. (författare)
  • Does gold concentration in the blood influence the result of patch testing to gold?
  • 2009
  • Ingår i: British Journal of Dermatology. - : Oxford University Press (OUP). - 1365-2133 .- 0007-0963. ; 160:5, s. 1016-1021
  • Tidskriftsartikel (refereegranskat)abstract
    • We have recently found a correlation between contact allergy to gold sodium thiosulphate (GSTS) and gold concentration in the blood (B-Au) in a stented population: the higher the B-Au, the stronger the patch-test reaction. To further investigate the correlation between B-Au and patch-test reactivity to gold. In this provocation control cross-over trial of 24 patients with dermatitis with a known contact allergy to gold, the patients were randomized into two groups where one was topically provoked to gold (15 mg GSTS) and one to the control. All patients were simultaneously patch tested with GSTS in 10 aqueous dilutions (1.1 mg GSTS). Patch-test readings were performed and blood was drawn. After 6 weeks, the experiment was repeated and the group that had previously been provoked with gold was now provoked with the control and vice versa. B-Au was higher after gold provocation whereas no treatment effect was discerned for minimal eliciting concentration (MEC) or summarized test score (STS). Instead, significant differences in period effect were observed implying higher B-Au and STS and lower MEC on test occasion II. The most likely explanation is the increased B-Au and/or booster effect from test occasion I. There was a correlation between B-Au and MEC: the higher the B-Au, the lower the MEC. The correlation between B-Au and MEC indicates that the B-Au is of importance for the skin reactivity to gold.
  •  
2.
  • Netterlid, Eva, et al. (författare)
  • There is an association between contact allergy to aluminium and persistent subcutaneous nodules in children undergoing hyposensitization therapy.
  • 2009
  • Ingår i: Contact Dermatitis. - : Wiley. - 0105-1873 .- 1600-0536. ; 60:1, s. 41-49
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: The development of persistent itchy nodules at the injection site following hyposensitization therapy with aluminium-precipitated antigen extract has been described in several reports. Occasionally, contact allergy to aluminium has been reported in individuals with such nodules. OBJECTIVES: To investigate if hyposensitization therapy can induce contact allergy to aluminium and examine if there is any association between persistent subcutaneous nodules and aluminium allergy. PATIENTS/METHODS: Sixty-one children with allergic asthma and/or allergic rhinitis participated in the study of whom 37 had had hyposensitization therapy. The study consisted of a non-clinical part based on a questionnaire and a clinical part with a physical examination, self-assessment of itching, and patch testing. To secure an unbiased evaluation of possible reactions, the investigators were blinded. RESULTS: Contact allergy to aluminium was found in eight participants, all in the exposed group (8/37 versus 0/24, P = 0.02). Examination showed nodules on the upper arms in 13 participants, all in the group exposed to hyposensitization therapy. Nodules were over-represented in patients with contact allergy to aluminium. CONCLUSIONS: There was a statistically significant association between contact allergy to aluminium and persistent subcutaneous nodules in children who had had hyposensitization therapy.
  •  
3.
  • Svedman, Cecilia, et al. (författare)
  • A correlation found between contact allergy to stent material and restenosis of the coronary arteries.
  • 2009
  • Ingår i: Contact Dermatitis. - : Wiley. - 0105-1873 .- 1600-0536. ; 60:3, s. 158-164
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Metallic implants, stents, are increasingly being used especially in patients with stenosis of the cardiac vessels. Ten to thirty per cent of the patients suffer from restenosis regardless of aetiology. We have shown increased frequency of contact allergy to stent metals in stented patients. OBJECTIVES: To we evaluate whether contact allergy to stent material is a risk factor for restenosis. METHODS: Patients with stainless steel stents, with or without gold plating, were epicutaneously tested and answered a questionnaire. The restenosis rate was evaluated. RESULTS: We found a correlation between contact allergy to gold, gold stent, and restenosis (OR 2.3, CI 1.0-5.1, P = 0.04). The risk for restenosis was threefold increased when the patient was gold allergic and stented with a gold-plated stent. An increased degree of chest pain in gold-allergic patients stented with gold-plated stent was found. CONCLUSIONS: We found a correlation between contact allergy to gold, gold-stent, and restenosis. It may be of importance to consider contact allergy when developing new materials for stenting.
  •  