SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Hedberg U.) srt2:(1992-1994)"

Sökning: WFRF:(Hedberg U.) > (1992-1994)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Danielsson, B., et al. (författare)
  • Recent investigations on calorimetric biosensors
  • 1992
  • Ingår i: Sensors and Actuators B: Chemical. - 0925-4005. ; 6:1-3, s. 138-142
  • Tidskriftsartikel (refereegranskat)abstract
    • New applications of a flow-calorimetric biosensor system, the enzyme thermistor (ET) are described. The ET measures the reaction heat in a small column containing immobilized biocatalyst as a temperature change of the effluent from the column. Since most biological reactions are exothermic, the ET has a very broad applicability and numerous assays of clinical as well as biotechnological interest have been studied. The procedure is well suited for monitoring and control of biotechnological processes due to its high operational stability. New results from this area are presented as well as developments on an automated thermometric immunoassay (TELISA). Miniaturized ET devices are suitable for portable monitoring of, for instance, blood glucose. Other recent work includes determinations in organic solvents, direct characterization of immobilized biocatalysts and monitoring of bioactivities in solution.
  •  
2.
  • Hedberg, U., et al. (författare)
  • Development of a miniaturized glucose monitor for whole blood measurements
  • 1992
  • Ingår i: Biosensors '92 Proceedings : The Second World Congress on Biosensors - The Second World Congress on Biosensors. - 9781856171618 ; , s. 49-54
  • Konferensbidrag (refereegranskat)abstract
    • The glucose concentration in diluted whole blood has been measured, using a miniaturized thermal biosensor based on the enzyme thermistor principle. The biosensor is a small flow-injection system. A sample volume of 20μ1 is injected into a flow of 50μl/min. The heat produced when the sample passes the enzyme column is measured with a thermistor connected to a Wheatstone bridge. The enzyme column contains glucose oxidase and catalase co-immobilized on a solid support material. Samples of whole blood usually cause problems in flowsystems. The blood cells tend to block the enzyme column and the back pressure increases. We have tested a superporous agarose material as enzyme support material using ten-fold diluted samples of whole human blood. The blood was collected from the finger-tip and diluted with buffer containing an anticoagulant and sodium fluoride. The number of samples possible to inject and the accuracy compared to the Boehringer Mannheim Reflolux have been determined. At least 100 ten-fold diluted blood samples could be injected on a micro-column of superporous agarose. The obtained glucose concentration correlated well with the one obtained with the Boehringer Mannheim Reflolux.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2
Typ av publikation
konferensbidrag (1)
tidskriftsartikel (1)
Typ av innehåll
refereegranskat (2)
Författare/redaktör
Danielsson, B. (2)
Xie, B. (2)
Hedberg, U. (2)
Rank, M. (1)
Turner, A.P.F. (1)
KARUBE, I (1)
visa fler...
Heineman, W. R. (1)
Schmid, R. D. (1)
visa färre...
Lärosäte
Lunds universitet (2)
Språk
Engelska (2)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (2)
År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy