SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Ringh Mattias) srt2:(2022)"

Sökning: WFRF:(Ringh Mattias) > (2022)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Berglund, Ellinor, et al. (författare)
  • Wellbeing, emotional response and stress among lay responders dispatched to suspected out-of-hospital cardiac arrests
  • 2022
  • Ingår i: Resuscitation. - : Elsevier Ireland Ltd. - 0300-9572 .- 1873-1570. ; 170, s. 352-360
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Systems for smartphone dispatch of lay responders to perform cardio-pulmonary resuscitation (CPR) and bring automated external defibrillators to out-of-hospital cardiac arrests (OHCAs) are advocated by recent international guidelines and emerging worldwide. Objectives: This study aimed to investigate the emotional responses, posttraumatic stress reactions and levels of wellbeing among smartphone-alerted lay responders dispatched to suspected OHCAs. Methods: Lay responders were stratified by level of exposure: unexposed (Exp-0), tried to reach (Exp-1), and reached the suspected OHCA (Exp-2). Participants rated their emotional responses online, at 90 minutes and at 4–6 weeks after an incident. Level of emotional response was measured in two dimensions of core affect: “alertness” – from deactivation to activation, and “pleasantness” – from unpleasant to pleasant. At 4–6 weeks, WHO wellbeing index and level of posttraumatic stress (PTSD) were also rated. Results: Altogether, 915 (28%) unexposed and 1471 (64%) exposed responders completed the survey. Alertness was elevated in the exposed groups: Exp-0: 6.7 vs. Exp-1: 7.3 and Exp-2: 7.5, (p < 0.001) and pleasantness was highest in the unexposed group: 6.5, vs. Exp-1: 6.3, and Exp-2: 6.1, (p < 0.001). Mean scores for PTSD at follow-up was below clinical cut-off, Exp-0: 9.9, Exp-1: 8.9 and Exp-2: 8.8 (p = 0.065). Wellbeing index showed no differences, Exp-0: 78.0, Exp-1: 78.5 and Exp-2: 79.9 (p = 0.596). Conclusion: Smartphone dispatched lay responders rated the experience as high-energy and mainly positive. No harm to the lay responders was seen. The exposed groups had low posttraumatic stress scores and high-level general wellbeing at follow-up. © 2021
  •  
2.
  • Schierbeck, Sofia, et al. (författare)
  • Automated external defibrillators delivered by drones to patients with suspected out-of-hospital cardiac arrest
  • 2022
  • Ingår i: European Heart Journal. - : Oxford University Press (OUP). - 0195-668X .- 1522-9645. ; , s. 1478-1487
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims Early defibrillation is critical for the chance of survival in out-of-hospital cardiac arrest (OHCA). Drones, used to deliver automated external defibrillators (AEDs), may shorten time to defibrillation, but this has never been evaluated in real-life emergencies. The aim of this study was to investigate the feasibility of AED delivery by drones in real-life cases of OHCA. Methods and results In this prospective clinical trial, three AED-equipped drones were placed within controlled airspace in Sweden, covering approximately 80 000 inhabitants (125 km(2)). Drones were integrated in the emergency medical services for automated deployment in beyond-visual-line-of-sight flights: (i) test flights from 1 June to 30 September 2020 and (ii) consecutive real-life suspected OHCAs. Primary outcome was the proportion of successful AED deliveries when drones were dispatched in cases of suspected OHCA. Among secondary outcomes was the proportion of cases where AED drones arrived prior to ambulance and time benefit vs. ambulance. Totally, 14 cases were eligible for dispatch during the study period in which AED drones took off in 12 alerts to suspected OHCA, with a median distance to location of 3.1 km [interquartile range (IQR) 2.8-3.4). AED delivery was feasible within 9 m (IQR 7.5-10.5) from the location and successful in 11 alerts (92%). AED drones arrived prior to ambulances in 64%, with a median time benefit of 01:52 min (IQR 01:35-04:54) when drone arrived first. In an additional 61 test flights, the AED delivery success rate was 90% (55/61). Conclusion In this pilot study, we have shown that AEDs can be carried by drones to real-life cases of OHCA with a successful AED delivery rate of 92%. There was a time benefit as compared to emergency medical services in cases where the drone arrived first. However, further improvements are needed to increase dispatch rate and time benefits.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy