SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Sanchez Benito) srt2:(2007-2009)"

Sökning: WFRF:(Sanchez Benito) > (2007-2009)

  • Resultat 1-10 av 14
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Barrios, Carlos Angulo, et al. (författare)
  • Demonstration of slot-waveguide structures on silicon nitride / silicon oxide platform
  • 2007
  • Ingår i: Optics Express. - 1094-4087. ; 15:11, s. 6846-6856
  • Tidskriftsartikel (refereegranskat)abstract
    • We report on the first demonstration of guiding light in vertical slot-waveguides on silicon nitride/silicon oxide material system. Integrated ring resonators and Fabry-Perot cavities have been fabricated and characterized in order to determine optical features of the slot-waveguides. Group index behavior evidences guiding and confinement in the low-index slot region at O-band (1260-1370nm) telecommunication wavelengths. Propagation losses of < 20 dB/cm have been measured for the transverse-electric mode of the slot-waveguides.
  •  
2.
  •  
3.
  • Barrios, Carlos Angulo, et al. (författare)
  • Label-free optical biosensing with slot-waveguides
  • 2008
  • Ingår i: Optics Letters. - 0146-9592 .- 1539-4794. ; 33:7, s. 708-710
  • Tidskriftsartikel (refereegranskat)abstract
    • We demonstrate label-free molecule detection by using an integrated biosensor based on a Si3N4/SiO2 Slot-waveguide microring resonator. Bovine serum albumin (BSA) and anti-BSA molecular binding events on the sensor surface are monitored through the measurement of resonant wavelength shifts with varying biomolecule concentrations. The biosensor exhibited sensitivities of 1.8 and 3.2 nm/(ng/mm(2)) for the detection of anti-BSA and BSA, respectively. The estimated detection limits are 28 and 16 pg/mm(2) for anti-BSA and BSA, respectively, limited by wavelength resolution.
  •  
4.
  • Barrios, Carlos Angulo, et al. (författare)
  • Slot-waveguide biochemical sensor
  • 2007
  • Ingår i: Optics Letters. - 0146-9592 .- 1539-4794. ; 32:21, s. 3080-3082
  • Tidskriftsartikel (refereegranskat)abstract
    • We report an experimental demonstration of an integrated biochemical sensor based on a slot-waveguidemicroring resonator. The microresonator is fabricated on a Si3N4-SiO2 platform and operates at a wavelength of 1.3 mu m. The transmission spectrum of the sensor is measured with different ambient refractive indices ranging from n = 1. 33 to 1.42. A linear shift of the resonant wavelength with increasing ambient refractive index of 212 nm/refractive index units (RIU) is observed. The sensor detects a minimal refractive index variation of 2 X 10(-4) RIU.
  •  
5.
  • Barrios, Carlos A., et al. (författare)
  • Slot-waveguide biochemical sensor (vol 32, pg 2080, 2007)
  • 2008
  • Ingår i: Optics Letters. - : OPTICAL SOC AMER. - 0146-9592 .- 1539-4794. ; 33:21, s. 2554-2555
  • Tidskriftsartikel (refereegranskat)abstract
    • The group index, instead of the effective index, is used to analyze the performance of a Si(3)N(4)-SiO(2) slot-waveguide microring refractive index sensor [Opt. Lett. 32, 3080 (2007)]. Assuming that the slot is fully filled with liquid, excellent agreement is found between experimental results and calculations.
  •  
6.
  •  
7.
  •  
8.
  •  
9.
  •  
10.
  • Kazmierczak, Andrzej, et al. (författare)
  • High quality optical microring resonators in Si3N 4/SiO2
  • 2008
  • Ingår i: Proceedings of the 14th European Conference on Integrated Optics - ECIO'08 Eindhoven. - 9789038613178 ; , s. 313-316
  • Konferensbidrag (refereegranskat)abstract
    • We have experimentally demonstrated high Q-factors strip waveguide resonators using the Si3N4/SiO2 material platform at the wavelength of 1.31μm. The analyzed filters demonstrate high quality factors reaching 133,000. The dependence on resonator radii and coupling gap is also discussed.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 14

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy