SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Zander J) srt2:(1995-1999)"

Sökning: WFRF:(Zander J) > (1995-1999)

  • Resultat 1-8 av 8
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  •  
4.
  •  
5.
  •  
6.
  • Lindblad, K, et al. (författare)
  • Two commonly expanded CAG/CTG repeat loci : involvement in affectivedisorders?
  • 1998
  • Ingår i: Molecular Psychiatry. - : Springer Science and Business Media LLC. - 1359-4184 .- 1476-5578. ; 3:5, s. 405-410
  • Tidskriftsartikel (refereegranskat)abstract
    • An association between bipolar affective disorder and CAG/CTG trinucleotide repeat expansions (TRE) has previously been detected using the repeat expansion detection (RED) method. Here we report that 89% of RED products (CAG/CTG repeats) > 120 nt (n = 202) detected in affective disorder patients as well as unaffected family members and controls correlate with expansions at two repeat loci, ERDA1 on chromosome 17q21.3 and CTG18.1 on 18q21.1. In a set of patients and controls in which we had previously found a significant difference in RED size distribution, the frequency of expansions at the CTG18.1 locus was 13% in bipolar patients (n = 60) and 5% in controls (n = 114) (P < 0.07) with a significantly different size distribution (P < 0.03). A second set of patients were ascertained from 14 affective disorder families showing anticipation. Twelve of the families had members with RED products > 120 nt. The RED product distribution was significantly different (P < 0.0007) between affected (n = 53) and unaffected (n = 123) offspring. Using PCR, a higher frequency (P < 0.04) of CTG18.1 expansions as well as a different (P < 0.02) repeat size distribution was seen between affected and unaffected offspring. In addition, a negative correlation between RED product size and the age-of-onset could be seen in affected offspring (rs = -0.3, P = 0.05, n = 43). This effect was due to an earlier onset in individuals with long CTG18.1 expansions. No difference in ERDA1 expansion frequency was seen either between bipolar patients (35%, n = 60) and matched controls (29%, n = 114), or between affected and unaffected offspring in the families. We conclude that expanded alleles at the CTG18.1 locus confers an odds ratio of 2.6-2.8 and may thus act as a vulnerability factor for affective disorder, while the ERDA1 locus seems unrelated to disease.
  •  
7.
  •  
8.
  • Zander, C, et al. (författare)
  • Multivariate analysis of factors influencing repeat expansion detection
  • 1998
  • Ingår i: Genome research. - : Cold Spring Harbor Laboratory. - 1088-9051 .- 1549-5469. ; 8:10, s. 1085-1094
  • Tidskriftsartikel (refereegranskat)abstract
    • Repeat expansion detection (RED) is a powerful tool for detection of expanded repeat sequences in the genome. In RED, DNA serves as a template for a repeat-specific oligonucleotide. A thermostable ligase is used to ligate oligonucleotides that have annealed at adjacent positions, creating multimers in a thermal cycling procedure. The products are visualized after gel electrophoresis, transfered to a membrane and subsequently hybridized. Multiple linear regression (MLR) and partial least square (PLS) techniques were used to reveal the most influential factors in the amplification reaction and to identify possible interacting factors. Ligation temperature proved to be the most important factor in the reaction: Temperatures far below the melting point of the oligonucleotide increased the yield considerably. Higher cycle number resulted in a continuous rise in intensity, indicating that the ligase remained active even after 700 cycles or 12 hr of cycling. In addition, the concentration of ligase was found to be important. Using optimal parameters, a 5.5- and 3.2-fold increase in the yield of 180- and 360-nucleotide products respectively was obtained. The improved sensitivity makes the method more robust and facilitates detection of repeat expansions. This improvement may be particularly useful in development of RED for diagnostic purposes as well as for nonradioactive detection of RED products. Based on these results, a new protocol for the RED method was developed taking into account the risk of introducing artifacts with increased enzyme concentrations and lowered annealing temperatures.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-8 av 8

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy