1.
  • Forsvall, A., et al. (författare)
  • An evaluation of the Rastreometro, a new device for populational screening for high blood pressure in developing countries
  • 2006
  • Ingår i: Arq Bras Cardiol. - 1678-4170. ; 87:4, s. 480-6
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: To test a simplified blood pressure device called Rastreometro that could be used by the Health Agents. METHODS: The Rastreometro has been developed from an ordinary aneroid sphygmomanometer, in which the numeric display is covered by an adhesive with a red zone, indicating pressures equal or above 140 mmHg and a yellow zone indicating pressures below 140 mmHg. The onset of oscillations of the aneroid needle is taken as an indication of the systolic pressure value. The measurements made by the Rastreometro were compared with those made by the auscultatory method, and were carried out in 268 patients, by two operators. The influence on the results of confounding variables such as age, gender, BMI, arm length, upper arm circumference, skin colour and antihypertensive treatment were taken into consideration, as well as intra and interobserver variation. RESULTS: In the whole group, sensitivity was 95.1%, specificity was 63.1%, positive predictive value was 62.4% and negative predictive value was 95.3%. Hypertensive treatment significantly affected specificity, 32.7% as compared to 77.8% for the non-treated group. Both operators improved their results over time. CONCLUSION: This study suggests that the Rastreometro technique, as a screener for hypertension, has good sensitivity. Concerning specificity, it is acceptable, provided the patient is not on regular antihypertensive treatment. In this latter situation, it can be improved by a proper standardization of the method to read the systolic pressure by needle oscillations. Furthermore, the use of this technique requires well trained operators.
  •  
2.
  •  
3.
  •  
4.
  • Rich, Rebecca L., et al. (författare)
  • A global benchmark study using affinity-based biosensors
  • 2009
  • Ingår i: Analytical Biochemistry. - : Elsevier BV. - 0003-2697 .- 1096-0309. ; 386:2, s. 194-216
  • Tidskriftsartikel (refereegranskat)abstract
    • To explore the variability in biosensor studies, 150 participants from 20 countries were given the same protein samples and asked to determine kinetic rate constants for the interaction. We chose a protein system that was amenable to analysis using different biosensor platforms as well as by users of different expertise levels. The two proteins (a 50-kDa Fab and a 60-kDa glutathione S-transferase [GST] antigen) form a relatively high-affinity complex, so participants needed to optimize several experimental parameters, including ligand immobilization and regeneration conditions as well as analyte concentrations and injection/dissociation times. Although most participants collected binding responses that could be fit to yield kinetic parameters, the quality of a few data sets could have been improved by optimizing the assay design. Once these outliers were removed, the average reported affinity across the remaining panel of participants was 620 pM with a standard deviation of 980 pM. These results demonstrate that when this biosensor assay was designed and executed appropriately, the reported rate constants were consistent, and independent of which protein was immobilized and which biosensor was used.
  •  