Topology optimization and characterization of Ti6A14V ELI cellular lattice structures by laser powder bed fusion for biomedical applications

Vilardell, Anna M. (författare)
Karlstads universitet,Institutionen för ingenjörsvetenskap och fysik (from 2013)
Takezawa, A. (författare)
Hiroshima Univ, Grad Sch Engn, Dept Transportat & Environm Syst, 1-4-1 Kagamiyama, Higashihiroshima, Hiroshima 7398527, Japan.
du Plessis, A. (författare)
Stellenbosch Univ, CT Scanner Facil & Phys Dept, ZA-7602 Stellenbosch, South Africa.
visa fler...
Takata, N. (författare)
Nagoya Univ, Grad Sch Engn, Dept Mat Proc Engn, Chikusa Ku, Furo Cho, Nagoya, Aichi 4648603, Japan.
Krakhmalev, Pavel, 1973- (författare)
Karlstads universitet,Institutionen för ingenjörsvetenskap och fysik (from 2013),Karlstad Univ, Dept Engn & Phys, SE-65188 Karlstad, Sweden.
Kobashi, M. (författare)
Nagoya Univ, Grad Sch Engn, Dept Mat Proc Engn, Chikusa Ku, Furo Cho, Nagoya, Aichi 4648603, Japan.
Yadroitsava, I. (författare)
Cent Univ Technol, Dept Mech & Mechatron Engn, ZA-9301 Bloemfontein, South Africa.
Yadroitsev, I. (författare)
Cent Univ Technol, Dept Mech & Mechatron Engn, ZA-9301 Bloemfontein, South Africa.
visa färre...
 (creator_code:org_t)
Elsevier, 2019
2019
Engelska.
Ingår i: Materials Science & Engineering. - : Elsevier. - 0921-5093 .- 1873-4936. ; 766, s. 1-11
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Topology optimization approach was used for the design of Ti6A14V ELI lattice structures with stiffness and density close to the human bone for implant applications. Three lattice designs with volume densities of 350/0, 40 % and 45 % and corresponding elastic modulus of 18.6 GPa, 23.1 GPa 27.4 GPa close to the human bone were generated. Laser powder bed fusion (LPBF) technique was used for the manufacturing of the specimens. Physical measurements and mechanical characterization of specimens were assessed by microCT analyses and compression test, perpendicular and parallel to the building direction of the specimens. LPBF Ti6A14V ELI manufactured lattice structures showed deviations in wall thickness in comparison with the generated designs, leading to an increase in relative porosity but also a decrease in elastic modulus in comparison with the original designs. Horizontal walls of the lattice structures showed higher wall thickness in comparison with the vertical walls, leading to anisotropic behaviour of the lattice structures. Higher elastic modulus and compression strength were obtained when thicker walls were oriented along the loading direction of the compression test, showing a complete failure by dividing the specimens into two neighbouring halves. All specimens showed 45 degrees diagonal shear fracture along the structure. On the other hand, higher energy absorption at first maximum compression strength peak was observed when samples were tested parallel to the building direction (when thinner walls were oriented along the loading compression direction). Results showed that designed lattice structures can possess the levels of human bones' stiffness and therefore can reduce/avoid stress shielding on implant applications.

Ämnesord

NATURVETENSKAP  -- Fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences (hsv//eng)

Nyckelord

Topology optimization
Cellular lattice structures
Laser powder bed fusion
Ti6A14V
Elastic modulus
Compression strength
Physics
Fysik

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy