Sökning: onr:"swepub:oai:DiVA.org:kth-146705" >
Energy-resolved CT ...
-
Persson, MatsKTH,Medicinsk bildfysik
(författare)
Energy-resolved CT imaging with a photon-counting silicon-strip detector
- Artikel/kapitelEngelska2014
Förlag, utgivningsår, omfång ...
-
SPIE - International Society for Optical Engineering,2014
-
printrdacarrier
Nummerbeteckningar
-
LIBRIS-ID:oai:DiVA.org:kth-146705
-
https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-146705URI
-
https://doi.org/10.1117/12.2043519DOI
Kompletterande språkuppgifter
-
Språk:engelska
-
Sammanfattning på:engelska
Ingår i deldatabas
Klassifikation
-
Ämneskategori:ref swepub-contenttype
-
Ämneskategori:kon swepub-publicationtype
Anmärkningar
-
QC 20140613
-
Photon-counting detectors are promising candidates for use in the next generation of x-ray CT scanners. Among the foreseen benefits are higher spatial resolution, better trade-off between noise and dose, and energy discriminating capabilities. Silicon is an attractive detector material because of its low cost, mature manufacturing process and high hole mobility. However, it is sometimes claimed to be unsuitable for use in computed tomography because of its low absorption efficiency and high fraction of Compton scatter. The purpose of this work is to demonstrate that high-quality energy-resolved CT images can nonetheless be acquired with clinically realistic exposure parameters using a photon-counting silicon-strip detector with eight energy thresholds developed in our group. We use a single detector module, consisting of a linear array of 50 0.5 × 0.4 mm detector elements, to image a phantom in a table-top lab setup. The phantom consists of a plastic cylinder with circular inserts containing water, fat and aqueous solutions of calcium, iodine and gadolinium, in different concentrations. We use basis material decomposition to obtain water, calcium, iodine and gadolinium basis images and demonstrate that these basis images can be used to separate the different materials in the inserts. We also show results showing that the detector has potential for quantitative measurements of substance concentrations.
Ämnesord och genrebeteckningar
Biuppslag (personer, institutioner, konferenser, titlar ...)
-
Huber, BenKTH,Medicinsk bildfysik(Swepub:kth)u155wnsr
(författare)
-
Karlsson, StaffanKTH,Medicinsk bildfysik(Swepub:kth)u1x1rpqq
(författare)
-
Liu, XuejinKTH,Medicinsk bildfysik(Swepub:kth)u1v6qm8u
(författare)
-
Chen, HanKTH,Medicinsk bildfysik(Swepub:kth)u1q2jdko
(författare)
-
Xu, ChengKTH,Medicinsk bildfysik(Swepub:kth)u1as48nl
(författare)
-
Yveborg, MoaKTH,Medicinsk bildfysik(Swepub:kth)u1xqdk4d
(författare)
-
Bornefalk, HansKTH,Medicinsk bildfysik(Swepub:kth)u1ng8smo
(författare)
-
Danielsson, MatsKTH,Medicinsk bildfysik(Swepub:kth)u1m3qe0f
(författare)
-
KTHMedicinsk bildfysik
(creator_code:org_t)
Sammanhörande titlar
-
Ingår i:Medical Imaging 2014: SPIE - International Society for Optical Engineering, s. 90333L-9780819498267
Internetlänk
Hitta via bibliotek
Till lärosätets databas