SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:kth-148611"
 

Sökning: onr:"swepub:oai:DiVA.org:kth-148611" > Endocardial border ...

Endocardial border delineation capability of a novel multimodal polymer-shelled contrast agent

Larsson, Malin K. (författare)
KTH,Medicinsk bildteknik,KTH, Medicinsk bildteknik
Larsson, Matilda (författare)
KTH,Medicinsk bildteknik,KTH, Medicinsk bildteknik
Nowak, Greg (författare)
visa fler...
Paradossi, Gaio (författare)
Brodin, Lars-Åke (författare)
KTH,Medicinsk bildteknik,KTH, Medicinsk bildteknik
Janerot Sjöberg, Birgitta (författare)
Karolinska Institutet,KTH,Medicinsk teknik,KTH, Medicinsk teknik
Caidahl, Kenneth (författare)
Karolinska Institutet
Bjällmark, Anna (författare)
KTH,Medicinsk bildteknik,KTH, Medicinsk bildteknik
visa färre...
 (creator_code:org_t)
2014-07-03
2014
Engelska.
Ingår i: Cardiovascular Ultrasound. - : Springer Science and Business Media LLC. - 1476-7120. ; 12, s. 24-
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: A novel polymer-shelled contrast agent (CA) with multimodal and target-specific potential was developed recently. To determine its ultrasonic diagnostic features, we evaluated the endocardial border delineation as visualized in a porcine model and the concomitant effect on physiological variables. Methods: Three doses of the novel polymer-shelled CA (1.5 ml, 3 ml, and 5 ml [5 x 10(8) microbubbles (MBs)/ml]) and the commercially available CA SonoVue (1.5 ml [2-5 x 10(8) MBs/ml]) were used. Visual evaluations of ultrasound images of the left ventricle were independently performed by three observers who graded each segment in a 6-segment model as either 0 = not visible, 1 = weakly visible, or 2 = visible. Moreover, the duration of clinically useful contrast enhancement and the left ventricular opacification were determined. During anesthesia, oxygen saturation, heart rate, and arterial pressure were sampled every minute and the effect of injection of CA on these physiological variables was evaluated. Results: The highest dose of the polymer-shelled CA gave results comparable to SonoVue. Thus, no significant difference in the overall segment score distribution (2-47-95 vs. 1-39-104), time for clinically sufficient contrast enhancement (20-40 s for both) and left ventricular overall opacification was found. In contrast, when comparing the endocardial border delineation capacity for different regions SonoVue showed significantly higher segment scores for base and mid, except for the mid region when injecting 1.5 ml of the polymer-shelled CA. Neither high nor low doses of the polymer-shelled CA significantly affected the investigated physiological variables. Conclusions: This study demonstrated that the novel polymer-shelled CA can be used in contrast-enhanced diagnostic imaging without influence on major physiological variables.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Nyckelord

Contrast agent
Echocardiography
Endocardial border delineation
Microbubbles
Polyvinyl alcohol
Porcine
Ultrasound

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy